Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-2.0/1103/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRBridging_onos-2.0_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit 5d60dcd8149968d626fff50733b7b6695c302a56 1990278de6f59d84cd81aebe84135050122b056b (HEAD -] onos-2.0, origin/onos-2.0)
Author: Charles Chan Thomas Vachuska [rascov@gmailtom@opennetworking.comorg]
AuthorDate: Wed Mon Apr 10 1715 09:1242:20 24 2019 -0700
Commit: Charles Chan Thomas Vachuska [rascov@gmailtom@opennetworking.comorg]
CommitDate: Fri Mon Apr 12 1415 09:3246:29 35 2019 -0700
Allowed apps to specify whether the existing component config value should be overridden
Replaced test mock with existing adapter in archetypes.

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS

...

  • 38.1 Apply cell to environment - PASS (tick)
  • 38.2 Uninstalling Atomix - PASS (tick)
  • 38.3 Uninstalling ONOS package - PASS (tick)
  • 38.4 Installing Atomix - PASS (tick)
  • 38.5 Installing ONOS package - PASS (tick)
  • 38.6 Set up ONOS secure SSH - PASS (tick)
  • 38.7 Checking ONOS service - PASS (tick)
  • 38.8 Starting ONOS CLI sessions - PASS (tick)
  • 38.9 Checking ONOS nodes - PASS (tick)
  • 38.10 Checking ONOS applications - PASS (tick)
  • 38.11 Starting Mininet Topology - PASS (tick)
  • 38.12 Check whether the flow count is bigger than 212 - PASS (tick)
  • 38.13 Check whether all flow status are ADDED - PASS (tick)
  • 38.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 38.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 38.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 38.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 38.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE38 - PASS (tick)
  • 38.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE38 - PASS (tick)
  • 38.20 Stopping Mininet - PASS (tick)
  • 38.21 Copying karaf logs - PASS (tick)

Case 45: Bridging test between untagged host and tagged host, with single ToR and 3 ONOS instances -

...

PASS

  • 45.1 Apply cell to environment - PASS (tick)
  • 45.2 Uninstalling Atomix - PASS (tick)
  • 45.3 Uninstalling ONOS package - PASS (tick)
  • 45.4 Installing Atomix - PASS (tick)
  • 45.5 Installing ONOS package - PASS (tick)
  • 45.6 Set up ONOS secure SSH - PASS (tick)
  • 45.7 Checking ONOS service - PASS (tick)
  • 45.8 Starting ONOS CLI sessions - PASS (tick)
  • 45.9 Checking ONOS nodes - PASS (tick)
  • 45.10 Checking ONOS applications - PASS (tick)
  • 45.11 Starting Mininet Topology - PASS (tick)
  • 45.12 Check whether the flow count is bigger than 28 - FAIL (error)
    • Flow count looks wrong: 3
  • PASS (tick)
  • 45.13 Check whether all flow status are ADDED - PASS (tick)
  • 45.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - FAIL (error)
    • Flow count looks wrong: 3
  • PASS (tick)
  • 45.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE45 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 45.16 Stopping Mininet - PASS (tick)
  • 45.17 Copying karaf logs - PASS (tick)

Case 46: Bridging test between untagged host and tagged host, with dual-homed ToR and 3 ONOS instances -

...

FAIL

  • 46.1 Apply cell to environment - PASS (tick)
  • 46.2 Uninstalling Atomix - PASS (tick)
  • 46.3 Uninstalling ONOS package - PASS (tick)
  • 46.4 Installing Atomix - PASS (tick)
  • 46.5 Installing ONOS package - PASS (tick)
  • 46.6 Set up ONOS secure SSH - PASS (tick)
  • 46.7 Checking ONOS service - PASS (tick)
  • 46.8 Starting ONOS CLI sessions - PASS (tick)
  • 46.9 Checking ONOS nodes - PASS (tick)
  • 46.10 Checking ONOS applications - PASS (tick)
  • 46.11 Starting Mininet Topology - PASS (tick)
  • 46.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 46.13 Check whether all flow status are ADDED - PASS (tick)
  • 46.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 46.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 46.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 46.17 Stopping Mininet - PASS (tick)
  • 46.18 Copying karaf logs - PASS (tick)

...