  • 15.1 Apply cell to environment - PASS (tick)
  • 15.2 Uninstalling Atomix - PASS (tick)
  • 15.3 Uninstalling ONOS package - PASS (tick)
  • 15.4 Installing Atomix - PASS (tick)
  • 15.5 Installing ONOS package - PASS (tick)
  • 15.6 Set up ONOS secure SSH - PASS (tick)
  • 15.7 Checking ONOS service - PASS (tick)
  • 15.8 Starting ONOS CLI sessions - PASS (tick)
  • 15.9 Checking ONOS nodes - PASS (tick)
  • 15.10 Checking ONOS applications - PASS (tick)
  • 15.11 Starting Mininet Topology - PASS (tick)
  • 15.12 Check whether the flow count is bigger than 28 - PASS (tick)
  • 15.13 Check whether all flow status are ADDED - PASS (tick)
  • 15.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 15.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE15 - PASS (tick)
  • 15.16 Stopping Mininet - PASS (tick)
  • 15.17 Copying karaf logs - PASS (tick)

Case 16: Bridging test between two tagged hosts, with dual-homed ToR and 3 ONOS instances -

...

FAIL

  • 16.1 Apply cell to environment - PASS (tick)
  • 16.2 Uninstalling Atomix - PASS (tick)
  • 16.3 Uninstalling ONOS package - PASS (tick)
  • 16.4 Installing Atomix - PASS (tick)
  • 16.5 Installing ONOS package - PASS (tick)
  • 16.6 Set up ONOS secure SSH - PASS (tick)
  • 16.7 Checking ONOS service - PASS (tick)
  • 16.8 Starting ONOS CLI sessions - PASS (tick)
  • 16.9 Checking ONOS nodes - PASS (tick)
  • 16.10 Checking ONOS applications - PASS (tick)
  • 16.11 Starting Mininet Topology - PASS (tick)
  • 16.12 Check whether the flow count is bigger than 74 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 6
  • 16.13 Check whether all flow status are ADDED - PASS (tick)
  • 16.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 3
  • 16.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 3
  • 16.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE16 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 16.17 Stopping Mininet - PASS (tick)
  • 16.18 Copying karaf logs - PASS (tick)

...

  • 45.1 Apply cell to environment - PASS (tick)
  • 45.2 Uninstalling Atomix - PASS (tick)
  • 45.3 Uninstalling ONOS package - PASS (tick)
  • 45.4 Installing Atomix - PASS (tick)
  • 45.5 Installing ONOS package - PASS (tick)
  • 45.6 Set up ONOS secure SSH - PASS (tick)
  • 45.7 Checking ONOS service - PASS (tick)
  • 45.8 Starting ONOS CLI sessions - PASS (tick)
  • 45.9 Checking ONOS nodes - PASS (tick)
  • 45.10 Checking ONOS applications - PASS (tick)
  • 45.11 Starting Mininet Topology - PASS (tick)
  • 45.12 Check whether the flow count is bigger than 28 - PASS (tick)
  • 45.13 Check whether all flow status are ADDED - PASS (tick)
  • 45.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 45.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE45 - PASS (tick)
  • 45.16 Stopping Mininet - PASS (tick)
  • 45.17 Copying karaf logs - PASS (tick)

Case 46: Bridging test between untagged host and tagged host, with dual-homed ToR and 3 ONOS instances -

...

PASS

  • 46.1 Apply cell to environment - PASS (tick)
  • 46.2 Uninstalling Atomix - PASS (tick)
  • 46.3 Uninstalling ONOS package - PASS (tick)
  • 46.4 Installing Atomix - PASS (tick)
  • 46.5 Installing ONOS package - PASS (tick)
  • 46.6 Set up ONOS secure SSH - PASS (tick)
  • 46.7 Checking ONOS service - PASS (tick)
  • 46.8 Starting ONOS CLI sessions - PASS (tick)
  • 46.9 Checking ONOS nodes - PASS (tick)
  • 46.10 Checking ONOS applications - PASS (tick)
  • 46.11 Starting Mininet Topology - PASS (tick)
  • 46.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 46.13 Check whether all flow status are ADDED - PASS (tick)
  • 46.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 46.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 46.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 46.17 Stopping Mininet - PASS (tick)
  • 46.18 Copying karaf logs - PASS (tick)

...

  • 47.1 Apply cell to environment - PASS (tick)
  • 47.2 Uninstalling Atomix - PASS (tick)
  • 47.3 Uninstalling ONOS package - PASS (tick)
  • 47.4 Installing Atomix - PASS (tick)
  • 47.5 Installing ONOS package - PASS (tick)
  • 47.6 Set up ONOS secure SSH - PASS (tick)
  • 47.7 Checking ONOS service - PASS (tick)
  • 47.8 Starting ONOS CLI sessions - PASS (tick)
  • 47.9 Checking ONOS nodes - PASS (tick)
  • 47.10 Checking ONOS applications - PASS (tick)
  • 47.11 Starting Mininet Topology - PASS (tick)
  • 47.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 47.13 Check whether all flow status are ADDED - PASS (tick)
  • 47.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 47.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 47.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - PASS (tick)
  • 47.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - PASS (tick)
  • 47.18 Stopping Mininet - PASS (tick)
  • 47.19 Copying karaf logs - PASS (tick)

Case 48: Bridging test between untagged host and tagged host, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 48.1 Apply cell to environment - PASS (tick)
  • 48.2 Uninstalling Atomix - PASS (tick)
  • 48.3 Uninstalling ONOS package - PASS (tick)
  • 48.4 Installing Atomix - PASS (tick)
  • 48.5 Installing ONOS package - PASS (tick)
  • 48.6 Set up ONOS secure SSH - PASS (tick)
  • 48.7 Checking ONOS service - PASS (tick)
  • 48.8 Starting ONOS CLI sessions - PASS (tick)
  • 48.9 Checking ONOS nodes - PASS (tick)
  • 48.10 Checking ONOS applications - PASS (tick)
  • 48.11 Starting Mininet Topology - PASS (tick)
  • 48.12 Check whether the flow count is bigger than 212 - PASS (tick)
  • 48.13 Check whether all flow status are ADDED - PASS (tick)
  • 48.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 48.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 48.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 48.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 48.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE48 - PASS (tick)
  • 48.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE48 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 48.20 Stopping Mininet - PASS (tick)
  • 48.21 Copying karaf logs - PASS (tick)

...