Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-master/481/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRDynamic_master_20-builds_graph.jpg", alt="SRDynamic", style="width:525px;height:350px;border:0">

commit 86561530ccffad273ffb1f0b0f80bfcf5006afa8 1bea289a917be2eae8d54f7f95d892aeaf658eb4 (HEAD -] master, origin/master, origin/HEAD)
Author: jaegonkim debmaiti [jaegon77deb.kim@samsungmaiti@samsung.com]
AuthorDate: Sat May 18 08:56:22 2019 +0900Tue Jun 4 12:36:38 2019 +0530
Commit: jaegonkim Carmelo Cascone [jaegon77carmelo@opennetworking.kim@samsung.comorg]
CommitDate: Sat May 18 08:56:22 2019 +0900
[ONOS-7732] Automating switch workflow - workplace print cliFri Jun 21 01:07:55 2019 +0000

Bug Fix in DistributedMeterStore

Case 1: Bridging and Routing sanity test with 2x2 Leaf-spineand 1 nodes. - FAIL

...

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Creating ONOS package - PASS (tick)
  • 2.5 Installing Atomix - PASS (tick)
  • 2.6 Installing ONOS package - PASS (tick)
  • 2.7 Set up ONOS secure SSH - PASS (tick)
  • 2.8 Checking ONOS service - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Starting Mininet Topology - PASS (tick)
  • 2.13 Check whether the flow count is bigger than 350 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 138
  • 2.14 Check whether all flow status are ADDED - PASS (tick)
  • 2.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 2.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 2.18 Pushing new configuration - No Result (warning)
  • 2.19 Pushing new configuration - No Result (warning)
  • 2.20 Check whether the flow count is bigger than 380 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 138
  • 2.21 Check whether all flow status are ADDED - PASS (tick)
  • 2.22 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8', 'in1', 'out1'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.23 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS (tick)
  • 2.24 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS (tick)
  • 2.25 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE2 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 2.26 Stopping Mininet - PASS (tick)
  • 2.27 Copying karaf logs - PASS (tick)

...