Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRBridging_master_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0"> |
commit 7afc75259f367d5e5d595c2b7a2f166b13c83c3e c97122204adfd63841807f1c5bb5fa46a2d9049a (HEAD -] master, origin/master, origin/HEAD)
Author: pier [pier@opennetworking.orgHarshada Chaundkar [Harshada_Chaundkar@comcast.com]
AuthorDate: Fri May 10 Tue Jul 2 15:13:19:15 24 2019 +02000000
Commit: pier [pier@opennetworking.org]
CommitDate: Wed Jul 10 23:0141:29 22 2019 +0200
Do not accumulate VERSATILE fwd objectives
Fix for host store not updated when host moves
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS
...
- 37.1 Apply cell to environment - PASS
- 37.2 Uninstalling Atomix - PASS
- 37.3 Uninstalling ONOS package - PASS
- 37.4 Installing Atomix - PASS
- 37.5 Installing ONOS package - PASS
- 37.6 Set up ONOS secure SSH - PASS
- 37.7 Checking ONOS service - PASS
- 37.8 Starting ONOS CLI sessions - PASS
- 37.9 Checking ONOS nodes - PASS
- 37.10 Checking ONOS applications - PASS
- 37.11 Starting Mininet Topology - PASS
- 37.12 Check whether the flow count is bigger than 74 - PASS
- 37.13 Check whether all flow status are ADDED - PASS
- 37.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 37.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 37.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - PASS
- 37.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - PASS
- 37.18 Stopping Mininet - PASS
- 37.19 Copying karaf logs - PASS
Case 38: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
PASS
- 38.1 Apply cell to environment - PASS
- 38.2 Uninstalling Atomix - PASS
- 38.3 Uninstalling ONOS package - PASS
- 38.4 Installing Atomix - PASS
- 38.5 Installing ONOS package - PASS
- 38.6 Set up ONOS secure SSH - PASS
- 38.7 Checking ONOS service - PASS
- 38.8 Starting ONOS CLI sessions - PASS
- 38.9 Checking ONOS nodes - PASS
- 38.10 Checking ONOS applications - PASS
- 38.11 Starting Mininet Topology - PASS
- 38.12 Check whether the flow count is bigger than 212 - PASS
- 38.13 Check whether all flow status are ADDED - PASS
- 38.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL
- Flow count looks wrong: 17
- PASS
- 38.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL Flow count looks wrong: 22
- PASS
- 38.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - FAIL
- Flow count looks wrong: 20
- PASS
- 38.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 38.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE38 - FAIL
- IP connectivity failed
- PASS
- 38.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE38 - FAIL IP connectivity failed
- PASS
- 38.20 Stopping Mininet - PASS
- 38.21 Copying karaf logs - PASS
...