  • 8.1 Comparing ONOS topology to MN topology - PASS (tick)
  • 8.2 Hosts view is consistent across all ONOS nodes - PASS (tick)
  • 8.3 Hosts information is correct - PASS (tick)
  • 8.4 Host attachment points to the network - PASS (tick)
  • 8.5 Clusters view is consistent across all ONOS nodes - PASS (tick)
  • 8.6 There is only one SCC - PASS (tick)
  • 8.7 Device information is correct - PASS (tick)
  • 8.8 Links are correct - PASS (tick)
  • 8.9 Hosts are correct - PASS (tick)
  • 8.10 Checking ONOS nodes - PASS (tick)

Case 7: Running ONOS Constant State Tests -

...

FAIL

  • 7.1 Check that each switch has a master - PASS (tick)
  • 7.2 Read device roles from ONOS - PASS (tick)
  • 7.3 Check for consistency in roles from each controller - PASS (tick)
  • 7.4 Get the intents from each controller - PASS (tick)
  • 7.5 Check for consistency in Intents from each controller - PASS (tick)
  • 7.6 Compare current intents with intents before the failure - PASS (tick)
  • 7.7 Get the OF Table entries and compare to before component failure - PASS (tick)FAIL (error)
    • Changes were found in the flow tables
  • 7.8 Leadership Election is still functional - PASS (tick)

...

  • 8.1 Comparing ONOS topology to MN topology - PASS (tick)
  • 8.2 Hosts view is consistent across all ONOS nodes - PASS (tick)
  • 8.3 Hosts information is correct - PASS (tick)
  • 8.4 Host attachment points to the network - PASS (tick)
  • 8.5 Clusters view is consistent across all ONOS nodes - PASS (tick)
  • 8.6 There is only one SCC - PASS (tick)
  • 8.7 Device information is correct - PASS (tick)
  • 8.8 Links are correct - PASS (tick)
  • 8.9 Hosts are correct - PASS (tick)
  • 8.10 Checking ONOS nodes - PASS (tick)

Case 7: Running ONOS Constant State Tests - FAIL

  • 7.1 Check that each switch has a master - PASS (tick)
  • 7.2 Read device roles from ONOS - PASS (tick)
  • 7.3 Check for consistency in roles from each controller - FAIL (error)
  • ONOS nodes have different views of switch roles
  • PASS (tick)
  • 7.4 Get the intents from each controller - PASS (tick)
  • 7.5 Check for consistency in Intents from each controller - PASS (tick)
  • 7.6 Compare current intents with intents before the failure - PASS (tick)
  • 7.7 Get the OF Table entries and compare to before component failure - PASS (tick)FAIL (error)
    • Changes were found in the flow tables
  • 7.8 Leadership Election is still functional - FAIL (error)
  • Something went wrong with Leadership election
  • PASS (tick)

Case 4: Verify connectivity by sending traffic across Intents - PASS

...