commit 0af90b91614c189b4e2d409ef068ba3a2469eb8c 0f9ee27d477c868aabd4fc8eef873b8502f0b44b (HEAD -] onos-1.15, origin/onos-1.15)
Author: Harshada Chaundkar [Harshada_Chaundkar@comcastJian Li [pyguni@gmail.com]
AuthorDate: Tue Jul 2 1530 19:1312:24 07 2019 +00000900
Commit: pier Jian Li [pier@opennetworkingpyguni@gmail.orgcom]
CommitDate: Thu Tue Jul 11 0830 23:2526:56 02 2019 +02000900

Fix for host store not updated when host moves: remove flow rules when removing POD and namespace

Case 1: Cluster Restart test with 2x2 Leaf-spine - FAIL

...

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Creating ONOS package - PASS (tick)
  • 2.5 Installing Atomix - PASS (tick)
  • 2.6 Installing ONOS package - PASS (tick)
  • 2.7 Set up ONOS secure SSH - PASS (tick)
  • 2.8 Checking ONOS service - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Starting Mininet Topology - PASS (tick)
  • 2.13 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.14 Check whether all flow status are ADDED - PASS (tick)
  • 2.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS (tick)
  • 2.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS (tick)
  • 2.18 Killing ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 2.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - PASS (tick)
  • 2.21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - PASS (tick)
  • 2.22 Recovering ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 2.23 Checking if ONOS CLI is ready - PASS (tick)
  • 2.24 Checking if ONOS CLI is ready - PASS (tick)
  • 2.25 Checking if ONOS CLI is ready - PASS (tick)
  • 2.26 Checking ONOS nodes - PASS (tick)
  • 2.27 Check number of topology elements - PASS (tick)
  • 2.28 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.29 Check whether all flow status are ADDED - PASS (tick)
  • 2.30 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.31 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - PASS (tick)
  • 2.32 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - PASS (tick)
  • 2.33 Stopping Mininet - PASS (tick)
  • 2.34 Copying karaf logs - PASS (tick)

Case 3: Cluster Restart test with single switch -

...

FAIL