Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-2.2/12/

...

commit 3a224b4fe93f66d000920f53f74c5b997b51545c (HEAD -] onos-2.2, origin/onos-2.2)
Author: Andrea Campanella [andrea@opennetworking.org]
AuthorDate: Thu Aug 29 16:51:14 2019 -0700
Commit: Andrea Campanella [andrea@opennetworking.org]
CommitDate: Wed Sep 4 15:54:35 2019 +0000

Adding wavlength tuning via GUI
--
(cherry picked from commit 6ac13ff484c70a9da6633e21dcb585c682b41c2f)

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances -

...

FAIL

  • 5.1 Constructing test variables - PASS (tick)
  • 5.2 Apply cell to environment - PASS (tick)
  • 5.3 Uninstalling Atomix - PASS (tick)
  • 5.4 Uninstalling ONOS package - PASS (tick)
  • 5.5 Creating ONOS package - PASS (tick)
  • 5.6 Installing Atomix - PASS (tick)
  • 5.7 Installing ONOS package - PASS (tick)
  • 5.8 Set up ONOS secure SSH - PASS (tick)
  • 5.9 Checking ONOS service - PASS (tick)
  • 5.10 Starting ONOS CLI sessions - PASS (tick)
  • 5.11 Checking ONOS nodes - PASS (tick)
  • 5.12 Checking ONOS applications - PASS (tick)
  • 5.13 Starting Mininet Topology - PASS (tick)
  • 5.14 Check whether the flow count is bigger than 28 - PASS (tick)
  • 5.15 Check whether all flow status are ADDED - PASS (tick)
  • 5.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 5.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 5.18 Stopping Mininet - PASS (tick)
  • 5.19 Copying karaf logs - PASS (tick)

...

  • 26.1 Apply cell to environment - PASS (tick)
  • 26.2 Uninstalling Atomix - PASS (tick)
  • 26.3 Uninstalling ONOS package - PASS (tick)
  • 26.4 Installing Atomix - PASS (tick)
  • 26.5 Installing ONOS package - PASS (tick)
  • 26.6 Set up ONOS secure SSH - PASS (tick)
  • 26.7 Checking ONOS service - PASS (tick)
  • 26.8 Starting ONOS CLI sessions - PASS (tick)
  • 26.9 Checking ONOS nodes - PASS (tick)
  • 26.10 Checking ONOS applications - PASS (tick)
  • 26.11 Starting Mininet Topology - PASS (tick)
  • 26.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 26.13 Check whether all flow status are ADDED - PASS (tick)
  • 26.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 26.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 26.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE26 - PASS (tick)
  • 26.17 Stopping Mininet - PASS (tick)
  • 26.18 Copying karaf logs - PASS (tick)

Case 27: Bridging test between two untagged hosts on vlan-native port, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 27.1 Apply cell to environment - PASS (tick)
  • 27.2 Uninstalling Atomix - PASS (tick)
  • 27.3 Uninstalling ONOS package - PASS (tick)
  • 27.4 Installing Atomix - PASS (tick)
  • 27.5 Installing ONOS package - PASS (tick)
  • 27.6 Set up ONOS secure SSH - PASS (tick)
  • 27.7 Checking ONOS service - PASS (tick)
  • 27.8 Starting ONOS CLI sessions - PASS (tick)
  • 27.9 Checking ONOS nodes - PASS (tick)
  • 27.10 Checking ONOS applications - PASS (tick)
  • 27.11 Starting Mininet Topology - PASS (tick)
  • 27.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 27.13 Check whether all flow status are ADDED - PASS (tick)
  • 27.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 27.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 27.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - PASS (tick)
  • 27.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 27.18 Stopping Mininet - PASS (tick)
  • 27.19 Copying karaf logs - PASS (tick)

...

  • 36.1 Apply cell to environment - PASS (tick)
  • 36.2 Uninstalling Atomix - PASS (tick)
  • 36.3 Uninstalling ONOS package - PASS (tick)
  • 36.4 Installing Atomix - PASS (tick)
  • 36.5 Installing ONOS package - PASS (tick)
  • 36.6 Set up ONOS secure SSH - PASS (tick)
  • 36.7 Checking ONOS service - PASS (tick)
  • 36.8 Starting ONOS CLI sessions - PASS (tick)
  • 36.9 Checking ONOS nodes - PASS (tick)
  • 36.10 Checking ONOS applications - PASS (tick)
  • 36.11 Starting Mininet Topology - PASS (tick)
  • 36.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 36.13 Check whether all flow status are ADDED - PASS (tick)
  • 36.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 36.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 36.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE36 - PASS (tick)
  • 36.17 Stopping Mininet - PASS (tick)
  • 36.18 Copying karaf logs - PASS (tick)

Case 37: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 37.1 Apply cell to environment - PASS (tick)
  • 37.2 Uninstalling Atomix - PASS (tick)
  • 37.3 Uninstalling ONOS package - PASS (tick)
  • 37.4 Installing Atomix - PASS (tick)
  • 37.5 Installing ONOS package - PASS (tick)
  • 37.6 Set up ONOS secure SSH - PASS (tick)
  • 37.7 Checking ONOS service - PASS (tick)
  • 37.8 Starting ONOS CLI sessions - PASS (tick)
  • 37.9 Checking ONOS nodes - PASS (tick)
  • 37.10 Checking ONOS applications - PASS (tick)
  • 37.11 Starting Mininet Topology - PASS (tick)
  • 37.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 37.13 Check whether all flow status are ADDED - PASS (tick)
  • 37.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 37.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 37.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - PASS (tick)
  • 37.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 37.18 Stopping Mininet - PASS (tick)
  • 37.19 Copying karaf logs - PASS (tick)

...

  • 45.1 Apply cell to environment - PASS (tick)
  • 45.2 Uninstalling Atomix - PASS (tick)
  • 45.3 Uninstalling ONOS package - PASS (tick)
  • 45.4 Installing Atomix - PASS (tick)
  • 45.5 Installing ONOS package - PASS (tick)
  • 45.6 Set up ONOS secure SSH - PASS (tick)
  • 45.7 Checking ONOS service - PASS (tick)
  • 45.8 Starting ONOS CLI sessions - PASS (tick)
  • 45.9 Checking ONOS nodes - PASS (tick)
  • 45.10 Checking ONOS applications - PASS (tick)
  • 45.11 Starting Mininet Topology - PASS (tick)
  • 45.12 Check whether the flow count is bigger than 28 - PASS (tick)
  • 45.13 Check whether all flow status are ADDED - PASS (tick)
  • 45.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 45.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE45 - PASS (tick)
  • 45.16 Stopping Mininet - PASS (tick)
  • 45.17 Copying karaf logs - PASS (tick)

Case 46: Bridging test between untagged host and tagged host, with dual-homed ToR and 3 ONOS instances -

...

PASS

  • 46.1 Apply cell to environment - PASS (tick)
  • 46.2 Uninstalling Atomix - PASS (tick)
  • 46.3 Uninstalling ONOS package - PASS (tick)
  • 46.4 Installing Atomix - PASS (tick)
  • 46.5 Installing ONOS package - PASS (tick)
  • 46.6 Set up ONOS secure SSH - PASS (tick)
  • 46.7 Checking ONOS service - PASS (tick)
  • 46.8 Starting ONOS CLI sessions - PASS (tick)
  • 46.9 Checking ONOS nodes - PASS (tick)
  • 46.10 Checking ONOS applications - PASS (tick)
  • 46.11 Starting Mininet Topology - PASS (tick)
  • 46.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 46.13 Check whether all flow status are ADDED - PASS (tick)
  • 46.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 46.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 46.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 46.17 Stopping Mininet - PASS (tick)
  • 46.18 Copying karaf logs - PASS (tick)

...