Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://onos-jenkins.onlab.us/job/USECASE_SdnipFunction_fsfw/119/

...

commit dd415c31d8a0d57fbe4a3ab721e2a95d7afa4495 (HEAD, origin/onos-1.3, onos-1.3)
Author: Jonathan Hart [jono@onlab.us]
AuthorDate: Mon Nov 16 10:56:20 2015 -0800
Commit: Jonathan Hart [jono@onlab.us]
CommitDate: Mon Nov 16 14:14:24 2015 -0800

Protect against exceptions thrown in application's packet processors.

Case 101: Setting up test environment - PASS

  • 101.1 Applying cell variable to environment - PASS (tick)
  • 101.2 Creating ONOS package - PASS (tick)
  • 101.3 Installing ONOS package - PASS (tick)
  • 101.4 Checking if ONOS is up yet - PASS (tick)
  • 101.5 Checking if ONOS CLI is ready - PASS (tick)
  • 101.6 Activate sdn-ip application - PASS (tick)

Case 102: Loading methods from other Python file - PASS

Case 1: Ping tests between BGP peers and speakers - PASS

  • 1.1 BGP speakers ping peers, expect all tests to succeed - PASS (tick)

Case 2: Check point-to-point intents - PASS

  • 2.1 Check P2P intents number from ONOS CLI - PASS (tick)

Case 3: Check routes and M2S intents to all BGP peers - PASS

  • 3.1 Check routes installed - PASS (tick)
  • 3.2 Check M2S intents installed - PASS (tick)
  • 3.3 Check whether all flow status are ADDED - PASS (tick)

Case 4: Ping test for each route, all hosts behind BGP peers - PASS

  • 4.1 Check ping between each host pair - PASS (tick)

Case 7: Stop edge sw32,check P-2-P and M-2-S intents, ping test - PASS

  • 7.1 Stop sw32 - PASS (tick)
  • 7.2 Check routes installed - PASS (tick)
  • 7.3 Check M2S intents installed - PASS (tick)
  • 7.4 Check P2P intents installed - PASS (tick)
  • 7.5 Check ping between hosts behind BGP peers - PASS (tick)
  • 7.6 Check ping between BGP peers and speakers - PASS (tick)
  • 7.7 Check whether all flow status are ADDED - PASS (tick)

Case 8: Start the edge sw32, check P-2-P and M-2-S intents, ping test - PASS

...

.

...

Case 9: Stop sw11 located in best path, check route number, P2P intent number, M2S intent number, ping test - FAIL

  • 9.1 Check flow entry number in sw11 - FAIL (error)
    • Flow number in sw11 is wrong!
  • 9.2 Check flow entry number in sw1 - FAIL (error)
    • Flow number in sw1 is wrong!
  • 9.3 Check flow entry number in sw7 - FAIL (error)
    • Flow number in sw7 is wrong!
  • 9.4 Stop sw11 - PASS (tick)
  • 9.5 Check routes installed - PASS (tick)
  • 9.6 Check M2S intents installed - PASS (tick)
  • 9.7 Check P2P intents installed - PASS (tick)
  • 9.8 Check whether all flow status are ADDED - PASS (tick)
  • 9.9 BGP speakers ping peers, expect all tests to succeed - PASS (tick)
  • 9.10 Check ping between each host pair - PASS (tick)

Case 10: Start sw11 which was stopped in CASE9, check route number, P2P intent number, M2S intent number, ping test - FAIL

...

  • Flow number in sw1 is wrong!

...

  • Flow number in sw7 is wrong!

...