Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-master/602/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRBridging_master_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit ab98a1fbc54d8914048b4b4f319898400057d84e 246dadcd8dfe6d7dff07767f3de4551aadba3764 (HEAD -] master, origin/master, origin/HEAD)
Author: Jian Li CyberHasH [pyguni@gmailb67gary@gmail.com]
AuthorDate: Fri Sat Oct 4 135 02:5237:12 50 2019 +09000800
Commit: Jian Li CyberHasH [pyguni@gmailb67gary@gmail.com]
CommitDate: Fri Sat Oct 4 145 06:4739:52 40 2019 +0900
Fix: resolve a NPE when removing VLAN typed openstack network0800

[ONOS-8037] Update basic makefile and gitignore and recompiled the pipeline, tested with reactive forwarding

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS

...

  • 46.1 Apply cell to environment - PASS (tick)
  • 46.2 Uninstalling Atomix - PASS (tick)
  • 46.3 Uninstalling ONOS package - PASS (tick)
  • 46.4 Installing Atomix - PASS (tick)
  • 46.5 Installing ONOS package - PASS (tick)
  • 46.6 Set up ONOS secure SSH - PASS (tick)
  • 46.7 Checking ONOS service - PASS (tick)
  • 46.8 Starting ONOS CLI sessions - PASS (tick)
  • 46.9 Checking ONOS nodes - PASS (tick)
  • 46.10 Checking ONOS applications - PASS (tick)
  • 46.11 Starting Mininet Topology - PASS (tick)
  • 46.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 46.13 Check whether all flow status are ADDED - PASS (tick)
  • 46.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 46.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 46.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - PASS (tick)
  • 46.17 Stopping Mininet - PASS (tick)
  • 46.18 Copying karaf logs - PASS (tick)

Case 47: Bridging test between untagged host and tagged host, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 47.1 Apply cell to environment - PASS (tick)
  • 47.2 Uninstalling Atomix - PASS (tick)
  • 47.3 Uninstalling ONOS package - PASS (tick)
  • 47.4 Installing Atomix - PASS (tick)
  • 47.5 Installing ONOS package - PASS (tick)
  • 47.6 Set up ONOS secure SSH - PASS (tick)
  • 47.7 Checking ONOS service - PASS (tick)
  • 47.8 Starting ONOS CLI sessions - PASS (tick)
  • 47.9 Checking ONOS nodes - PASS (tick)
  • 47.10 Checking ONOS applications - PASS (tick)
  • 47.11 Starting Mininet Topology - PASS (tick)
  • 47.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 47.13 Check whether all flow status are ADDED - PASS (tick)
  • 47.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 47.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 47.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 47.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - PASS (tick)
  • 47.18 Stopping Mininet - PASS (tick)
  • 47.19 Copying karaf logs - PASS (tick)

...

  • 67.1 Apply cell to environment - PASS (tick)
  • 67.2 Uninstalling Atomix - PASS (tick)
  • 67.3 Uninstalling ONOS package - PASS (tick)
  • 67.4 Installing Atomix - PASS (tick)
  • 67.5 Installing ONOS package - PASS (tick)
  • 67.6 Set up ONOS secure SSH - PASS (tick)
  • 67.7 Checking ONOS service - PASS (tick)
  • 67.8 Starting ONOS CLI sessions - PASS (tick)
  • 67.9 Checking ONOS nodes - PASS (tick)
  • 67.10 Checking ONOS applications - PASS (tick)
  • 67.11 Starting Mininet Topology - PASS (tick)
  • 67.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 67.13 Check whether all flow status are ADDED - PASS (tick)
  • 67.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 67.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 67.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE67 - PASS (tick)
  • 67.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE67 - PASS (tick)
  • 67.18 Stopping Mininet - PASS (tick)
  • 67.19 Copying karaf logs - PASS (tick)

Case 68: Bridging test between two tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

PASS

  • 68.1 Apply cell to environment - PASS (tick)
  • 68.2 Uninstalling Atomix - PASS (tick)
  • 68.3 Uninstalling ONOS package - PASS (tick)
  • 68.4 Installing Atomix - PASS (tick)
  • 68.5 Installing ONOS package - PASS (tick)
  • 68.6 Set up ONOS secure SSH - PASS (tick)
  • 68.7 Checking ONOS service - PASS (tick)
  • 68.8 Starting ONOS CLI sessions - PASS (tick)
  • 68.9 Checking ONOS nodes - PASS (tick)
  • 68.10 Checking ONOS applications - PASS (tick)
  • 68.11 Starting Mininet Topology - PASS (tick)
  • 68.12 Check whether the flow count is bigger than 212 - PASS (tick)
  • 68.13 Check whether all flow status are ADDED - PASS (tick)
  • 68.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 68.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 68.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 68.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - FAIL (error)
    • Flow count looks wrong: 18
  • PASS (tick)
  • 68.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE68 - PASS (tick)
  • 68.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE68 - PASS (tick)
  • 68.20 Stopping Mininet - PASS (tick)
  • 68.21 Copying karaf logs - PASS (tick)

...

  • 76.1 Apply cell to environment - PASS (tick)
  • 76.2 Uninstalling Atomix - PASS (tick)
  • 76.3 Uninstalling ONOS package - PASS (tick)
  • 76.4 Installing Atomix - PASS (tick)
  • 76.5 Installing ONOS package - PASS (tick)
  • 76.6 Set up ONOS secure SSH - PASS (tick)
  • 76.7 Checking ONOS service - PASS (tick)
  • 76.8 Starting ONOS CLI sessions - PASS (tick)
  • 76.9 Checking ONOS nodes - PASS (tick)
  • 76.10 Checking ONOS applications - PASS (tick)
  • 76.11 Starting Mininet Topology - PASS (tick)
  • 76.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 76.13 Check whether all flow status are ADDED - PASS (tick)
  • 76.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 76.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 76.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE76 - PASS (tick)
  • 76.17 Stopping Mininet - PASS (tick)
  • 76.18 Copying karaf logs - PASS (tick)

Case 77: Bridging test between untagged and tagged hosts with different vlan id, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 77.1 Apply cell to environment - PASS (tick)
  • 77.2 Uninstalling Atomix - PASS (tick)
  • 77.3 Uninstalling ONOS package - PASS (tick)
  • 77.4 Installing Atomix - PASS (tick)
  • 77.5 Installing ONOS package - PASS (tick)
  • 77.6 Set up ONOS secure SSH - PASS (tick)
  • 77.7 Checking ONOS service - PASS (tick)
  • 77.8 Starting ONOS CLI sessions - PASS (tick)
  • 77.9 Checking ONOS nodes - PASS (tick)
  • 77.10 Checking ONOS applications - PASS (tick)
  • 77.11 Starting Mininet Topology - PASS (tick)
  • 77.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 77.13 Check whether all flow status are ADDED - PASS (tick)
  • 77.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 77.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 17
  • 77.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE77 - PASS (tick)
  • 77.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE77 - PASS (tick)
  • 77.18 Stopping Mininet - PASS (tick)
  • 77.19 Copying karaf logs - PASS (tick)

...