Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRBridging_onos-1.15_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0"> |
commit e547d16d84edd56991d4bb21781fc7a1aadf717a 70261cfd8a3b0ffa0f50e5d20675e143f9e89e9f (HEAD -] onos-1.15, origin/onos-1.15)
Author: Jian Li pier [pyguni@gmailpier@opennetworking.comorg]
AuthorDate: Fri Oct 4 13:52:12 Jun 28 22:17:31 2019 +09000200
Commit: Jian Li pier [pyguni@gmailpier@opennetworking.comorg]
CommitDate: Fri Oct 4 0411 15:5634:55 34 2019 +0000
Fix: resolve a NPE when removing VLAN typed openstack network0200
Improves ping responder
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS
...
- 26.1 Apply cell to environment - PASS
- 26.2 Uninstalling Atomix - PASS
- 26.3 Uninstalling ONOS package - PASS
- 26.4 Installing Atomix - PASS
- 26.5 Installing ONOS package - PASS
- 26.6 Set up ONOS secure SSH - PASS
- 26.7 Checking ONOS service - PASS
- 26.8 Starting ONOS CLI sessions - PASS
- 26.9 Checking ONOS nodes - PASS
- 26.10 Checking ONOS applications - PASS
- 26.11 Starting Mininet Topology - PASS
- 26.12 Check whether the flow count is bigger than 74 - PASS
- 26.13 Check whether all flow status are ADDED - PASS
- 26.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 26.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 26.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE26 - PASS
- 26.17 Stopping Mininet - PASS
- 26.18 Copying karaf logs - PASS
Case 27: Bridging test between two untagged hosts on vlan-native port, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 27.1 Apply cell to environment - PASS
- 27.2 Uninstalling Atomix - PASS
- 27.3 Uninstalling ONOS package - PASS
- 27.4 Installing Atomix - PASS
- 27.5 Installing ONOS package - PASS
- 27.6 Set up ONOS secure SSH - PASS
- 27.7 Checking ONOS service - PASS
- 27.8 Starting ONOS CLI sessions - PASS
- 27.9 Checking ONOS nodes - PASS
- 27.10 Checking ONOS applications - PASS
- 27.11 Starting Mininet Topology - PASS
- 27.12 Check whether the flow count is bigger than 74 - PASS
- 27.13 Check whether all flow status are ADDED - PASS
- 27.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 27.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS FAIL
- Flow count looks wrong: 17
- 27.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - PASS
- 27.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - PASS FAIL
- IP connectivity failed
- 27.18 Stopping Mininet - PASS
- 27.19 Copying karaf logs - PASS
...
- 35.1 Apply cell to environment - PASS
- 35.2 Uninstalling Atomix - PASS
- 35.3 Uninstalling ONOS package - PASS
- 35.4 Installing Atomix - PASS
- 35.5 Installing ONOS package - PASS
- 35.6 Set up ONOS secure SSH - PASS
- 35.7 Checking ONOS service - PASS
- 35.8 Starting ONOS CLI sessions - PASS
- 35.9 Checking ONOS nodes - PASS
- 35.10 Checking ONOS applications - PASS
- 35.11 Starting Mininet Topology - PASS
- 35.12 Check whether the flow count is bigger than 28 - PASS
- 35.13 Check whether all flow status are ADDED - PASS
- 35.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 35.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE35 - PASS
- 35.16 Stopping Mininet - PASS
- 35.17 Copying karaf logs - PASS
Case 36: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with dual-homed ToR and 3 ONOS instances -
...
PASS
- 36.1 Apply cell to environment - PASS
- 36.2 Uninstalling Atomix - PASS
- 36.3 Uninstalling ONOS package - PASS
- 36.4 Installing Atomix - PASS
- 36.5 Installing ONOS package - PASS
- 36.6 Set up ONOS secure SSH - PASS
- 36.7 Checking ONOS service - PASS
- 36.8 Starting ONOS CLI sessions - PASS
- 36.9 Checking ONOS nodes - PASS
- 36.10 Checking ONOS applications - PASS
- 36.11 Starting Mininet Topology - PASS
- 36.12 Check whether the flow count is bigger than 74 - PASS
- 36.13 Check whether all flow status are ADDED - PASS
- 36.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 36.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL
- Flow count looks wrong: 18
- PASS
- 36.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE36 - FAIL
- IP connectivity failed
- PASS
- 36.17 Stopping Mininet - PASS
- 36.18 Copying karaf logs - PASS
...
- 57.1 Apply cell to environment - PASS
- 57.2 Uninstalling Atomix - PASS
- 57.3 Uninstalling ONOS package - PASS
- 57.4 Installing Atomix - PASS
- 57.5 Installing ONOS package - PASS
- 57.6 Set up ONOS secure SSH - PASS
- 57.7 Checking ONOS service - PASS
- 57.8 Starting ONOS CLI sessions - PASS
- 57.9 Checking ONOS nodes - PASS
- 57.10 Checking ONOS applications - PASS
- 57.11 Starting Mininet Topology - PASS
- 57.12 Check whether the flow count is bigger than 74 - PASS
- 57.13 Check whether all flow status are ADDED - PASS
- 57.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 57.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 57.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE57 - PASS
- 57.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE57 - PASS
- 57.18 Stopping Mininet - PASS
- 57.19 Copying karaf logs - PASS
Case 58: Bridging test between two untagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
FAIL
- 58.1 Apply cell to environment - PASS
- 58.2 Uninstalling Atomix - PASS
- 58.3 Uninstalling ONOS package - PASS
- 58.4 Installing Atomix - PASS
- 58.5 Installing ONOS package - PASS
- 58.6 Set up ONOS secure SSH - PASS
- 58.7 Checking ONOS service - PASS
- 58.8 Starting ONOS CLI sessions - PASS
- 58.9 Checking ONOS nodes - PASS
- 58.10 Checking ONOS applications - PASS
- 58.11 Starting Mininet Topology - PASS
- 58.12 Check whether the flow count is bigger than 212 - PASS
- 58.13 Check whether all flow status are ADDED - PASS
- 58.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 21
- 58.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 16
- 58.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 16
- 58.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 16
- 58.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE58 - PASS
- 58.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE58 - PASS
- 58.20 Stopping Mininet - PASS
- 58.21 Copying karaf logs - PASS
...