Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances -
...
FAIL
- 5.1 Constructing test variables - PASS
- 5.2 Apply cell to environment - PASS
- 5.3 Uninstalling Atomix - PASS
- 5.4 Uninstalling ONOS package - PASS
- 5.5 Creating ONOS package - PASS
- 5.6 Installing Atomix - PASS
- 5.7 Installing ONOS package - PASS
- 5.8 Set up ONOS secure SSH - PASS FAIL
- Failed to secure ssh
- 5.9 Checking ONOS service - PASS
- 5.10 Starting ONOS CLI sessions - PASS
- 5.11 Checking ONOS nodes - PASS
- 5.12 Checking ONOS applications - PASS
- 5.13 Starting Mininet Topology - PASS
- 5.14 Check whether the flow count is bigger than 28 - PASS
- 5.15 Check whether all flow status are ADDED - PASS
- 5.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 5.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS
- 5.18 Stopping Mininet - PASS
- 5.19 Copying karaf logs - PASS
...
- 15.1 Apply cell to environment - PASS
- 15.2 Uninstalling Atomix - PASS
- 15.3 Uninstalling ONOS package - PASS
- 15.4 Installing Atomix - PASS
- 15.5 Installing ONOS package - PASS
- 15.6 Set up ONOS secure SSH - PASS
- 15.7 Checking ONOS service - PASS
- 15.8 Starting ONOS CLI sessions - PASS
- 15.9 Checking ONOS nodes - PASS
- 15.10 Checking ONOS applications - PASS
- 15.11 Starting Mininet Topology - PASS
- 15.12 Check whether the flow count is bigger than 28 - PASS
- 15.13 Check whether all flow status are ADDED - PASS
- 15.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 15.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE15 - PASS
- 15.16 Stopping Mininet - PASS
- 15.17 Copying karaf logs - PASS
Case 16: Bridging test between two tagged hosts, with dual-homed ToR and 3 ONOS instances -
...
PASS
- 16.1 Apply cell to environment - PASS
- 16.2 Uninstalling Atomix - PASS
- 16.3 Uninstalling ONOS package - PASS
- 16.4 Installing Atomix - PASS
- 16.5 Installing ONOS package - PASS
- 16.6 Set up ONOS secure SSH - FAIL
- Failed to secure ssh
- PASS
- 16.7 Checking ONOS service - PASS
- 16.8 Starting ONOS CLI sessions - PASS
- 16.9 Checking ONOS nodes - PASS
- 16.10 Checking ONOS applications - PASS
- 16.11 Starting Mininet Topology - PASS
- 16.12 Check whether the flow count is bigger than 74 - PASS
- 16.13 Check whether all flow status are ADDED - PASS
- 16.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 16.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 16.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE16 - PASS
- 16.17 Stopping Mininet - PASS
- 16.18 Copying karaf logs - PASS
...
- 18.1 Apply cell to environment - PASS
- 18.2 Uninstalling Atomix - PASS
- 18.3 Uninstalling ONOS package - PASS
- 18.4 Installing Atomix - PASS
- 18.5 Installing ONOS package - PASS
- 18.6 Set up ONOS secure SSH - PASS
- 18.7 Checking ONOS service - PASS
- 18.8 Starting ONOS CLI sessions - PASS
- 18.9 Checking ONOS nodes - PASS
- 18.10 Checking ONOS applications - PASS
- 18.11 Starting Mininet Topology - PASS
- 18.12 Check whether the flow count is bigger than 212 - PASS
- 18.13 Check whether all flow status are ADDED - PASS
- 18.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 18.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 18.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 18.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 18.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS
- 18.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS
- 18.20 Stopping Mininet - PASS
- 18.21 Copying karaf logs - PASS
Case 25: Bridging test between two untagged hosts on vlan-native port, with single ToR and 3 ONOS instances -
...
PASS
- 25.1 Apply cell to environment - PASS
- 25.2 Uninstalling Atomix - PASS
- 25.3 Uninstalling ONOS package - PASS
- 25.4 Installing Atomix - PASS
- 25.5 Installing ONOS package - PASS
- 25.6 Set up ONOS secure SSH - FAIL Failed to secure ssh
- PASS
- 25.7 Checking ONOS service - PASS
- 25.8 Starting ONOS CLI sessions - PASS
- 25.9 Checking ONOS nodes - PASS
- 25.10 Checking ONOS applications - PASS
- 25.11 Starting Mininet Topology - PASS
- 25.12 Check whether the flow count is bigger than 28 - PASS
- 25.13 Check whether all flow status are ADDED - PASS
- 25.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 25.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE25 - PASS
- 25.16 Stopping Mininet - PASS
- 25.17 Copying karaf logs - PASS
...