- 15.1 Apply cell to environment - PASS
- 15.2 Uninstalling Atomix - PASS
- 15.3 Uninstalling ONOS package - PASS
- 15.4 Installing Atomix - PASS
- 15.5 Installing ONOS package - PASS
- 15.6 Set up ONOS secure SSH - PASS
- 15.7 Checking ONOS service - PASS
- 15.8 Starting ONOS CLI sessions - PASS
- 15.9 Checking ONOS nodes - PASS
- 15.10 Checking ONOS applications - PASS
- 15.11 Starting Mininet Topology - PASS
- 15.12 Check whether the flow count is bigger than 28 - PASS
- 15.13 Check whether all flow status are ADDED - PASS
- 15.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 15.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE15 - PASS
- 15.16 Stopping Mininet - PASS
- 15.17 Copying karaf logs - PASS
Case 16: Bridging test between two tagged hosts, with dual-homed ToR and 3 ONOS instances -
...
FAIL
- 16.1 Apply cell to environment - PASS
- 16.2 Uninstalling Atomix - PASS
- 16.3 Uninstalling ONOS package - PASS
- 16.4 Installing Atomix - PASS
- 16.5 Installing ONOS package - PASS
- 16.6 Set up ONOS secure SSH - PASS
- 16.7 Checking ONOS service - PASS
- 16.8 Starting ONOS CLI sessions - PASS
- 16.9 Checking ONOS nodes - PASS
- 16.10 Checking ONOS applications - PASS
- 16.11 Starting Mininet Topology - PASS
- 16.12 Check whether the flow count is bigger than 74 - PASS
- 16.13 Check whether all flow status are ADDED - PASS
- 16.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 16.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 16.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE16 - PASS FAIL
- IP connectivity failed
- 16.17 Stopping Mininet - PASS
- 16.18 Copying karaf logs - PASS
...
- 18.1 Apply cell to environment - PASS
- 18.2 Uninstalling Atomix - PASS
- 18.3 Uninstalling ONOS package - PASS
- 18.4 Installing Atomix - PASS
- 18.5 Installing ONOS package - PASS
- 18.6 Set up ONOS secure SSH - PASS
- 18.7 Checking ONOS service - PASS
- 18.8 Starting ONOS CLI sessions - PASS
- 18.9 Checking ONOS nodes - PASS
- 18.10 Checking ONOS applications - PASS
- 18.11 Starting Mininet Topology - PASS
- 18.12 Check whether the flow count is bigger than 212 - PASS
- 18.13 Check whether all flow status are ADDED - PASS
- 18.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 18.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 18.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 18.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 18.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS
- 18.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS
- 18.20 Stopping Mininet - PASS
- 18.21 Copying karaf logs - PASS
Case 25: Bridging test between two untagged hosts on vlan-native port, with single ToR and 3 ONOS instances -
...
PASS
- 25.1 Apply cell to environment - PASS
- 25.2 Uninstalling Atomix - PASS
- 25.3 Uninstalling ONOS package - PASS
- 25.4 Installing Atomix - PASS
- 25.5 Installing ONOS package - PASS
- 25.6 Set up ONOS secure SSH - PASS
- 25.7 Checking ONOS service - PASS
- 25.8 Starting ONOS CLI sessions - PASS
- 25.9 Checking ONOS nodes - PASS
- 25.10 Checking ONOS applications - PASS
- 25.11 Starting Mininet Topology - PASS
- 25.12 Check whether the flow count is bigger than 28 - PASS
- 25.13 Check whether all flow status are ADDED - PASS
- 25.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 25.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE25 - FAIL IP connectivity failed
- PASS
- 25.16 Stopping Mininet - PASS
- 25.17 Copying karaf logs - PASS
...
- 36.1 Apply cell to environment - PASS
- 36.2 Uninstalling Atomix - PASS
- 36.3 Uninstalling ONOS package - PASS
- 36.4 Installing Atomix - PASS
- 36.5 Installing ONOS package - PASS
- 36.6 Set up ONOS secure SSH - PASS
- 36.7 Checking ONOS service - PASS
- 36.8 Starting ONOS CLI sessions - PASS
- 36.9 Checking ONOS nodes - PASS
- 36.10 Checking ONOS applications - PASS
- 36.11 Starting Mininet Topology - PASS
- 36.12 Check whether the flow count is bigger than 74 - PASS
- 36.13 Check whether all flow status are ADDED - PASS
- 36.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 36.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 36.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE36 - PASS
- 36.17 Stopping Mininet - PASS
- 36.18 Copying karaf logs - PASS
Case 37: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 37.1 Apply cell to environment - PASS
- 37.2 Uninstalling Atomix - PASS
- 37.3 Uninstalling ONOS package - PASS
- 37.4 Installing Atomix - PASS
- 37.5 Installing ONOS package - PASS
- 37.6 Set up ONOS secure SSH - PASS
- 37.7 Checking ONOS service - PASS
- 37.8 Starting ONOS CLI sessions - PASS
- 37.9 Checking ONOS nodes - PASS
- 37.10 Checking ONOS applications - PASS
- 37.11 Starting Mininet Topology - PASS
- 37.12 Check whether the flow count is bigger than 74 - PASS
- 37.13 Check whether all flow status are ADDED - PASS
- 37.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 37.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 37.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - PASS
- 37.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - FAIL IP connectivity failed
- PASS
- 37.18 Stopping Mininet - PASS
- 37.19 Copying karaf logs - PASS
...
- 46.1 Apply cell to environment - PASS
- 46.2 Uninstalling Atomix - PASS
- 46.3 Uninstalling ONOS package - PASS
- 46.4 Installing Atomix - PASS
- 46.5 Installing ONOS package - PASS
- 46.6 Set up ONOS secure SSH - PASS
- 46.7 Checking ONOS service - PASS
- 46.8 Starting ONOS CLI sessions - PASS
- 46.9 Checking ONOS nodes - PASS
- 46.10 Checking ONOS applications - PASS
- 46.11 Starting Mininet Topology - PASS
- 46.12 Check whether the flow count is bigger than 74 - PASS
- 46.13 Check whether all flow status are ADDED - PASS
- 46.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 46.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 46.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - PASS
- 46.17 Stopping Mininet - PASS
- 46.18 Copying karaf logs - PASS
Case 47: Bridging test between untagged host and tagged host, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 47.1 Apply cell to environment - PASS
- 47.2 Uninstalling Atomix - PASS
- 47.3 Uninstalling ONOS package - PASS
- 47.4 Installing Atomix - PASS
- 47.5 Installing ONOS package - PASS
- 47.6 Set up ONOS secure SSH - PASS
- 47.7 Checking ONOS service - PASS
- 47.8 Starting ONOS CLI sessions - PASS
- 47.9 Checking ONOS nodes - PASS
- 47.10 Checking ONOS applications - PASS
- 47.11 Starting Mininet Topology - PASS
- 47.12 Check whether the flow count is bigger than 74 - PASS
- 47.13 Check whether all flow status are ADDED - PASS
- 47.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 47.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 47.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - PASS FAIL
- IP connectivity failed
- 47.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - PASS
- 47.18 Stopping Mininet - PASS
- 47.19 Copying karaf logs - PASS
...