Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRBridging_onos-1.15_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit 519970d1c8e59abd541091433fade0b982ac0dc4 fbd65dbd60d20878a3576de1fbd68d4bdee6f26c (HEAD -] onos-1.15, origin/onos-1.15)
Author: Shibu Vijayakumar Seyeon Jeong [shibuseyeon@opennetworking.vijayakumar@infosys.comorg]
AuthorDate: Thu Tue Mar 1 153 17:4533:59 2018 40 2020 -0800
Commit: Shibu Vijayakumar Charles Chan [shibucharles@opennetworking.vijayakumar@infosys.comorg]
CommitDate: Tue Mar 31 09:21:48 Thu Apr 2 19:02:32 2020 +0000

Fix bugs for dynamic interface configurationan action of t3-troubleshot-mcast command when no sink for a multicast route

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS

...

  • 36.1 Apply cell to environment - PASS (tick)
  • 36.2 Uninstalling Atomix - PASS (tick)
  • 36.3 Uninstalling ONOS package - PASS (tick)
  • 36.4 Installing Atomix - PASS (tick)
  • 36.5 Installing ONOS package - PASS (tick)
  • 36.6 Set up ONOS secure SSH - PASS (tick)
  • 36.7 Checking ONOS service - PASS (tick)
  • 36.8 Starting ONOS CLI sessions - PASS (tick)
  • 36.9 Checking ONOS nodes - PASS (tick)
  • 36.10 Checking ONOS applications - PASS (tick)
  • 36.11 Starting Mininet Topology - PASS (tick)
  • 36.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 36.13 Check whether all flow status are ADDED - PASS (tick)
  • 36.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 36.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 36.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE36 - PASS (tick)
  • 36.17 Stopping Mininet - PASS (tick)
  • 36.18 Copying karaf logs - PASS (tick)

Case 37: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 37.1 Apply cell to environment - PASS (tick)
  • 37.2 Uninstalling Atomix - PASS (tick)
  • 37.3 Uninstalling ONOS package - PASS (tick)
  • 37.4 Installing Atomix - PASS (tick)
  • 37.5 Installing ONOS package - PASS (tick)
  • 37.6 Set up ONOS secure SSH - PASS (tick)
  • 37.7 Checking ONOS service - PASS (tick)
  • 37.8 Starting ONOS CLI sessions - PASS (tick)
  • 37.9 Checking ONOS nodes - PASS (tick)
  • 37.10 Checking ONOS applications - PASS (tick)
  • 37.11 Starting Mininet Topology - PASS (tick)
  • 37.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 37.13 Check whether all flow status are ADDED - PASS (tick)
  • 37.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 37.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL (error)
  • Flow count looks wrong: 18
  • PASS (tick)
  • 37.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - PASS (tick)
  • 37.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 37.18 Stopping Mininet - PASS (tick)
  • 37.19 Copying karaf logs - PASS (tick)

...