Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRBridging_onos-2.2_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0"> |
commit 3bc3d5b746cf58b5ab192cb6d7f175ab6966e79d e80c15bc3580db128129cc170f152f1e8a09d8f2 (HEAD -] onos-2.2, origin/onos-2.2)
Author: Jian Li [pyguni@gmail.comONOS Jenkins User [jenkins@onlab.us]
AuthorDate: Wed Mon Sep 23 1628 17:4626:12 11 2020 +09000000
Commit: Jian Li [pyguni@gmail.comONOS Jenkins User [jenkins@onlab.us]
CommitDate: Wed Mon Sep 23 0828 17:3826:27 11 2020 +0000
Use port's MacAddress to associate ONOS port and Kubernetes port
Starting snapshot 2.2.6-SNAPSHOT
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, ovs switches and 3 ONOS instances - PASS
...
- 7.1 Apply cell to environment - PASS
- 7.2 Uninstalling Atomix - PASS
- 7.3 Uninstalling ONOS package - PASS
- 7.4 Installing Atomix - PASS
- 7.5 Installing ONOS package - PASS
- 7.6 Set up ONOS secure SSH - PASS
- 7.7 Checking ONOS service - PASS
- 7.8 Starting ONOS CLI sessions - PASS
- 7.9 Checking ONOS nodes - PASS
- 7.10 Checking ONOS applications - PASS
- 7.11 Set logging levels - PASS
- 7.12 Set ONOS configurations - PASS
- 7.13 Starting Mininet Topology - PASS
- 7.14 Check whether the flow count is bigger than 74 - PASS
- 7.15 Check whether all flow status are ADDED - PASS
- 7.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 7.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 7.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS
- 7.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS
- 7.20 Stopping Mininet - PASS
- 7.21 Copying karaf logs - PASS
Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances -
...
FAIL
- 8.1 Apply cell to environment - PASS
- 8.2 Uninstalling Atomix - PASS
- 8.3 Uninstalling ONOS package - PASS
- 8.4 Installing Atomix - PASS
- 8.5 Installing ONOS package - PASS
- 8.6 Set up ONOS secure SSH - PASS
- 8.7 Checking ONOS service - PASS
- 8.8 Starting ONOS CLI sessions - PASS
- 8.9 Checking ONOS nodes - PASS
- 8.10 Checking ONOS applications - PASS
- 8.11 Set logging levels - PASS
- 8.12 Set ONOS configurations - PASS
- 8.13 Starting Mininet Topology - PASS
- 8.14 Check whether the flow count is bigger than 212 - PASS
- 8.15 Check whether all flow status are ADDED - PASS
- 8.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 8.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 8.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 8.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 8.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - PASS
- 8.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - PASS FAIL
- IP connectivity failed
- 8.22 Stopping Mininet - PASS
- 8.23 Copying karaf logs - PASS
...
- 56.1 Apply cell to environment - PASS
- 56.2 Uninstalling Atomix - PASS
- 56.3 Uninstalling ONOS package - PASS
- 56.4 Installing Atomix - PASS
- 56.5 Installing ONOS package - PASS
- 56.6 Set up ONOS secure SSH - PASS
- 56.7 Checking ONOS service - PASS
- 56.8 Starting ONOS CLI sessions - PASS
- 56.9 Checking ONOS nodes - PASS
- 56.10 Checking ONOS applications - PASS
- 56.11 Set logging levels - PASS
- 56.12 Set ONOS configurations - PASS
- 56.13 Starting Mininet Topology - PASS
- 56.14 Check whether the flow count is bigger than 74 - PASS
- 56.15 Check whether all flow status are ADDED - PASS
- 56.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 56.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 56.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE56 - PASS
- 56.19 Stopping Mininet - PASS
- 56.20 Copying karaf logs - PASS
Case 57: Bridging test between two untagged hosts with different vlan id, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -
...
FAIL
- 57.1 Apply cell to environment - PASS
- 57.2 Uninstalling Atomix - PASS
- 57.3 Uninstalling ONOS package - PASS
- 57.4 Installing Atomix - PASS
- 57.5 Installing ONOS package - PASS
- 57.6 Set up ONOS secure SSH - PASS
- 57.7 Checking ONOS service - PASS
- 57.8 Starting ONOS CLI sessions - PASS
- 57.9 Checking ONOS nodes - PASS
- 57.10 Checking ONOS applications - PASS
- 57.11 Set logging levels - PASS
- 57.12 Set ONOS configurations - PASS
- 57.13 Starting Mininet Topology - PASS
- 57.14 Check whether the flow count is bigger than 74 - PASS
- 57.15 Check whether all flow status are ADDED - PASS
- 57.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 57.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS FAIL
- Flow count looks wrong: 25
- 57.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE57 - PASS
- 57.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE57 - PASS
- 57.20 Stopping Mininet - PASS
- 57.21 Copying karaf logs - PASS
...