Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRSanity_onos-2.2_20-builds_graph.jpg", alt="SRSanity", style="width:525px;height:350px;border:0">

commit 4027cac71993e8696091a9b3ca75ffe8df5a8e16 3433e31a961b0ce97cb731ceb67fcc7da0c854b5 (HEAD -] onos-2.2, origin/onos-2.2)
Author: Yi Tseng pierventre [yi@opennetworkingpier@opennetworking.org]
AuthorDate: Tue Oct 13 1927 16:1508:12 48 2020 -0700+0100
Commit: Yi Tseng [yi@opennetworkingPier Luigi Ventre [pier@opennetworking.org]
CommitDate: Fri Oct 23 08Thu Oct 29 10:36:07 :50 2020 +0000
Support install IntIntents to device with postcard mode
[ONOS-8123] Fix an issue related to the component properties.

Case 1: Bridging and Routing sanity test with 2x2 Leaf-spine and 1 Onos - PASS

...

  • 3.1 Apply cell to environment - PASS (tick)
  • 3.2 Uninstalling Atomix - PASS (tick)
  • 3.3 Uninstalling ONOS package - PASS (tick)
  • 3.4 Creating ONOS package - PASS (tick)
  • 3.5 Installing Atomix - PASS (tick)
  • 3.6 Installing ONOS package - PASS (tick)
  • 3.7 Set up ONOS secure SSH - PASS (tick)
  • 3.8 Checking ONOS service - PASS (tick)
  • 3.9 Starting ONOS CLI sessions - PASS (tick)
  • 3.10 Checking ONOS nodes - PASS (tick)
  • 3.11 Checking ONOS applications - PASS (tick)
  • 3.12 Set logging levels - PASS (tick)
  • 3.13 Set ONOS configurations - PASS (tick)
  • 3.14 Starting Mininet Topology - PASS (tick)
  • 3.15 Check whether the flow count is bigger than 15 - PASS (tick)
  • 3.16 Check whether all flow status are ADDED - PASS (tick)
  • 3.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE3 - PASS (tick)
  • 3.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - PASS (tick)
  • 3.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - PASS (tick)
  • 3.20 Verify full connectivity for [u'olt1', u'vsg1'] with tag CASE3 - PASS (tick)
  • 3.21 Stopping Mininet - PASS (tick)
  • 3.22 Copying karaf logs - PASS (tick)

Case 4: Bridging and Routing sanity test with 2x2 Leaf-spine and 3 Onos -

...

PASS

  • 4.1 Apply cell to environment - PASS (tick)
  • 4.2 Uninstalling Atomix - PASS (tick)
  • 4.3 Uninstalling ONOS package - PASS (tick)
  • 4.4 Creating ONOS package - PASS (tick)
  • 4.5 Installing Atomix - PASS (tick)
  • 4.6 Installing ONOS package - PASS (tick)
  • 4.7 Set up ONOS secure SSH - PASS (tick)
  • 4.8 Checking ONOS service - PASS (tick)
  • 4.9 Starting ONOS CLI sessions - PASS (tick)
  • 4.10 Checking ONOS nodes - PASS (tick)
  • 4.11 Checking ONOS applications - PASS (tick)
  • 4.12 Set logging levels - PASS (tick)
  • 4.13 Set ONOS configurations - PASS (tick)
  • 4.14 Starting Mininet Topology - PASS (tick)
  • 4.15 Check whether the flow count is bigger than 116 - PASS (tick)
  • 4.16 Check whether all flow status are ADDED - PASS (tick)
  • 4.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 4.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4 - PASS (tick)
  • 4.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4 - PASS (tick)
  • 4.20 Stopping Mininet - PASS (tick)
  • 4.21 Copying karaf logs - PASS (tick)

...

  • 5.1 Apply cell to environment - PASS (tick)
  • 5.2 Uninstalling Atomix - PASS (tick)
  • 5.3 Uninstalling ONOS package - PASS (tick)
  • 5.4 Creating ONOS package - PASS (tick)
  • 5.5 Installing Atomix - PASS (tick)
  • 5.6 Installing ONOS package - PASS (tick)
  • 5.7 Set up ONOS secure SSH - PASS (tick)
  • 5.8 Checking ONOS service - PASS (tick)
  • 5.9 Starting ONOS CLI sessions - PASS (tick)
  • 5.10 Checking ONOS nodes - PASS (tick)
  • 5.11 Checking ONOS applications - PASS (tick)
  • 5.12 Set logging levels - PASS (tick)
  • 5.13 Set ONOS configurations - PASS (tick)
  • 5.14 Starting Mininet Topology - PASS (tick)
  • 5.15 Check whether the flow count is bigger than 350 - PASS (tick)
  • 5.16 Check whether all flow status are ADDED - PASS (tick)
  • 5.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5 - PASS (tick)
  • 5.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5 - PASS (tick)
  • 5.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5 - PASS (tick)
  • 5.20 Stopping Mininet - PASS (tick)
  • 5.21 Copying karaf logs - PASS (tick)

Case 6: Bridging and Routing sanity test with single switch and 3 Onos -

...

PASS

  • 6.1 Apply cell to environment - PASS (tick)
  • 6.2 Uninstalling Atomix - PASS (tick)
  • 6.3 Uninstalling ONOS package - PASS (tick)
  • 6.4 Creating ONOS package - PASS (tick)
  • 6.5 Installing Atomix - PASS (tick)
  • 6.6 Installing ONOS package - PASS (tick)
  • 6.7 Set up ONOS secure SSH - PASS (tick)
  • 6.8 Checking ONOS service - PASS (tick)
  • 6.9 Starting ONOS CLI sessions - PASS (tick)
  • 6.10 Checking ONOS nodes - PASS (tick)
  • 6.11 Checking ONOS applications - PASS (tick)
  • 6.12 Set logging levels - PASS (tick)
  • 6.13 Set ONOS configurations - PASS (tick)
  • 6.14 Starting Mininet Topology - PASS (tick)
  • 6.15 Check whether the flow count is bigger than 15 - PASS (tick)
  • 6.16 Check whether all flow status are ADDED - PASS (tick)
  • 6.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS (tick)
  • 6.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE6 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 6.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE6 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 6.20 Verify full connectivity for [u'olt1', u'vsg1'] with tag CASE6 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 6.21 Stopping Mininet - PASS (tick)
  • 6.22 Copying karaf logs - PASS (tick)