  • 25.1 Apply cell to environment - PASS (tick)
  • 25.2 Uninstalling Atomix - PASS (tick)
  • 25.3 Uninstalling ONOS package - PASS (tick)
  • 25.4 Create Cluster Config - PASS (tick)
  • 25.5 Installing Atomix via docker containers - PASS (tick)
  • 25.6 Installing ONOS via docker containers - PASS (tick)
  • 25.7 Set up ONOS secure SSH - PASS (tick)
  • 25.8 Starting ONOS CLI sessions - PASS (tick)
  • 25.9 Checking ONOS nodes - PASS (tick)
  • 25.10 Checking ONOS applications - PASS (tick)
  • 25.11 Set logging levels - PASS (tick)
  • 25.12 Set ONOS configurations - PASS (tick)
  • 25.13 Starting Mininet Topology - PASS (tick)
  • 25.14 Configure switches in ONOS - PASS (tick)
  • 25.15 Check whether the flow count is bigger than 28 - PASS (tick)
  • 25.16 Check whether all flow status are ADDED - PASS (tick)
  • 25.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 28 - PASS (tick)
  • 25.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE25 - PASS (tick)
  • 25.19 Stopping Mininet - PASS (tick)
  • 25.20 Copying karaf logs - PASS (tick)

Case 26: Bridging test between two untagged hosts on vlan-native port, with dual-homed ToR, stratum switches and 3 ONOS instances -

...

FAIL

  • 26.1 Apply cell to environment - PASS (tick)
  • 26.2 Uninstalling Atomix - PASS (tick)
  • 26.3 Uninstalling ONOS package - PASS (tick)
  • 26.4 Create Cluster Config - PASS (tick)
  • 26.5 Installing Atomix via docker containers - PASS (tick)
  • 26.6 Installing ONOS via docker containers - PASS (tick)
  • 26.7 Set up ONOS secure SSH - PASS (tick)
  • 26.8 Starting ONOS CLI sessions - PASS (tick)
  • 26.9 Checking ONOS nodes - PASS (tick)
  • 26.10 Checking ONOS applications - PASS (tick)
  • 26.11 Set logging levels - PASS (tick)
  • 26.12 Set ONOS configurations - PASS (tick)
  • 26.13 Starting Mininet Topology - PASS (tick)
  • 26.14 Configure switches in ONOS - PASS (tick)
  • 26.15 Check whether the flow count is bigger than 74 - PASS (tick)FAIL (error)
    • Flow count looks wrong; found 63, expecting at least 74
  • 26.16 Check whether all flow status are ADDED - PASS (tick)
  • 26.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 37 - PASS (tick)
  • 26.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 0
  • 26.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE26 - PASS (tick)
  • 26.20 Stopping Mininet - PASS (tick)
  • 26.21 Copying karaf logs - PASS (tick)

...