- 17.1 Apply cell to environment - PASS
- 17.2 Uninstalling Atomix - PASS
- 17.3 Uninstalling ONOS package - PASS
- 17.4 Create Cluster Config - PASS
- 17.5 Installing Atomix via docker containers - PASS
- 17.6 Installing ONOS via docker containers - PASS
- 17.7 Set up ONOS secure SSH - PASS
- 17.8 Starting ONOS CLI sessions - PASS
- 17.9 Checking ONOS nodes - PASS
- 17.10 Checking ONOS applications - PASS
- 17.11 Set logging levels - PASS
- 17.12 Set ONOS configurations - PASS
- 17.13 Starting Mininet Topology - PASS
- 17.14 Configure switches in ONOS - PASS
- 17.15 Check whether the flow count is bigger than 64 - PASS
- 17.16 Check whether all flow status are ADDED - PASS
- 17.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 32 - PASS
- 17.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 32 - PASS
- 17.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - PASS
- 17.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - PASS
- 17.21 Stopping Mininet - PASS
- 17.22 Copying karaf logs - PASS
Case 18: Bridging test between two tagged hosts, with 2x4 dual-homed leaf-spine topology, stratum switches and 3 ONOS instances -
...
FAIL
- 18.1 Apply cell to environment - PASS
- 18.2 Uninstalling Atomix - PASS
- 18.3 Uninstalling ONOS package - PASS
- 18.4 Create Cluster Config - PASS
- 18.5 Installing Atomix via docker containers - PASS
- 18.6 Installing ONOS via docker containers - PASS
- 18.7 Set up ONOS secure SSH - PASS
- 18.8 Starting ONOS CLI sessions - PASS
- 18.9 Checking ONOS nodes - PASS
- 18.10 Checking ONOS applications - PASS
- 18.11 Set logging levels - PASS
- 18.12 Set ONOS configurations - PASS
- 18.13 Starting Mininet Topology - PASS
- 18.14 Configure switches in ONOS - PASS
- 18.15 Check whether the flow count is bigger than 212 - PASS
- 18.16 Check whether all flow status are ADDED - PASS
- 18.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 53 - PASS
- 18.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 50
- 18.19 Check whether the flow count of device device:bmv2:leaf3 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 13
- 18.20 Check whether the flow count of device device:bmv2:leaf4 is bigger than 53 - PASS
- 18.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS
- 18.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS FAIL
- IP connectivity failed
- 18.23 Stopping Mininet - PASS
- 18.24 Copying karaf logs - PASS
...
- 25.1 Apply cell to environment - PASS
- 25.2 Uninstalling Atomix - PASS
- 25.3 Uninstalling ONOS package - PASS
- 25.4 Create Cluster Config - PASS
- 25.5 Installing Atomix via docker containers - PASS
- 25.6 Installing ONOS via docker containers - PASS
- 25.7 Set up ONOS secure SSH - PASS
- 25.8 Starting ONOS CLI sessions - PASS
- 25.9 Checking ONOS nodes - PASS
- 25.10 Checking ONOS applications - PASS
- 25.11 Set logging levels - PASS
- 25.12 Set ONOS configurations - PASS
- 25.13 Starting Mininet Topology - PASS
- 25.14 Configure switches in ONOS - PASS
- 25.15 Check whether the flow count is bigger than 28 - PASS
- 25.16 Check whether all flow status are ADDED - PASS
- 25.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 28 - PASS
- 25.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE25 - PASS
- 25.19 Stopping Mininet - PASS
- 25.20 Copying karaf logs - PASS
Case 26: Bridging test between two untagged hosts on vlan-native port, with dual-homed ToR, stratum switches and 3 ONOS instances -
...
PASS
- 26.1 Apply cell to environment - PASS
- 26.2 Uninstalling Atomix - PASS
- 26.3 Uninstalling ONOS package - PASS
- 26.4 Create Cluster Config - PASS
- 26.5 Installing Atomix via docker containers - PASS
- 26.6 Installing ONOS via docker containers - PASS
- 26.7 Set up ONOS secure SSH - PASS
- 26.8 Starting ONOS CLI sessions - PASS
- 26.9 Checking ONOS nodes - PASS
- 26.10 Checking ONOS applications - PASS
- 26.11 Set logging levels - PASS
- 26.12 Set ONOS configurations - PASS
- 26.13 Starting Mininet Topology - PASS
- 26.14 Configure switches in ONOS - PASS
- 26.15 Check whether the flow count is bigger than 74 - FAIL
- Flow count looks wrong; found 63, expecting at least 74
- PASS
- 26.16 Check whether all flow status are ADDED - PASS
- 26.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 37 - PASS
- 26.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 37 - FAIL Flow count looks wrong: 0
- PASS
- 26.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE26 - PASS
- 26.20 Stopping Mininet - PASS
- 26.21 Copying karaf logs - PASS
...