Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRClusterRestart_master_20-builds_graph.jpg", alt="SRClusterRestart", style="width:525px;height:350px;border:0">

commit 066b09da1c4caab771995df05fec62e13ec7fa09 1d49a407f108aa14b01c4ca062ab8af02ce5f4d4 (HEAD -] master, origin/master, origin/HEAD)
Author: Eesha Deepak Carmelo Cascone [eesha@opennetworkingcarmelo@opennetworking.org]
AuthorDate: Tue Jul Mon Aug 9 20 08:1501:47 59 2021 -0700
Commit: Carmelo Cascone [carmelo@opennetworking.orgDaniele Moro [dmoro@Danieles-MacBook-Pro.local]
CommitDate: Mon Jul 26 Aug 16 16:22:42:24 00 2021 +0000
added the gnmi drivers to the publish target list0200

Fix wrong arguments in load_pdr action
--
(cherry picked from commit 94015dee30b6d98e2658e6ff1ba557f5ad5010b5)

Case 1: Cluster Restart test with 2x2 leaf-spine topology - FAIL

...

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing Atomix - PASS (tick)
  • 1.7 Installing ONOS package - PASS (tick)
  • 1.8 Set up ONOS secure SSH - PASS (tick)
  • 1.9 Checking ONOS service - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Set logging levels - PASS (tick)
  • 1.14 Set ONOS configurations - PASS (tick)
  • 1.15 Starting Mininet Topology - PASS (tick)
  • 1.16 Check whether the flow count is >= 116 - FAIL (error)
    • Flow count looks wrong; found 720, expecting at least 116
  • 1.17 Check whether all flow status are ADDED - PASS (tick)
  • 1.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.21 Killing ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 1.22 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.23 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.24 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.25 Recovering ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 1.26 Checking if ONOS CLI is ready - PASS (tick)
  • 1.27 Checking if ONOS CLI is ready - PASS (tick)
  • 1.28 Checking if ONOS CLI is ready - PASS (tick)
  • 1.29 Checking ONOS nodes - PASS (tick)
  • 1.30 Check number of topology elements - PASS (tick)
  • 1.31 Check whether the flow count is >= 116 - FAIL (error)
    • Flow count looks wrong; found 72, expecting at least 116
  • 1.32 Check whether all flow status are ADDED - PASS (tick)
  • 1.33 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.34 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.35 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.36 Stopping Mininet - PASS (tick)
  • 1.37 Copying karaf logs - PASS (tick)

...

  • 3.1 Apply cell to environment - PASS (tick)
  • 3.2 Uninstalling Atomix - PASS (tick)
  • 3.3 Uninstalling ONOS package - PASS (tick)
  • 3.4 Creating ONOS package - PASS (tick)
  • 3.5 Installing Atomix - PASS (tick)
  • 3.6 Installing ONOS package - PASS (tick)
  • 3.7 Set up ONOS secure SSH - PASS (tick)
  • 3.8 Checking ONOS service - PASS (tick)
  • 3.9 Starting ONOS CLI sessions - PASS (tick)
  • 3.10 Checking ONOS nodes - PASS (tick)
  • 3.11 Checking ONOS applications - PASS (tick)
  • 3.12 Set logging levels - PASS (tick)
  • 3.13 Set ONOS configurations - PASS (tick)
  • 3.14 Starting Mininet Topology - PASS (tick)
  • 3.15 Check whether the flow count is >= 15 - PASS (tick)FAIL (error)
    • Flow count looks wrong; found 0, expecting at least 15
  • 3.16 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 3.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.20 Verify full connectivity for [u'olt1', u'vsg1'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.21 Killing ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 3.22 Verify full connectivity for [u'h1', u'h2'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.23 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.24 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.25 Verify full connectivity for [u'olt1', u'vsg1'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.26 Recovering ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 3.27 Checking if ONOS CLI is ready - PASS (tick)
  • 3.28 Checking if ONOS CLI is ready - PASS (tick)
  • 3.29 Checking if ONOS CLI is ready - PASS (tick)
  • 3.30 Checking ONOS nodes - PASS (tick)
  • 3.31 Check number of topology elements - PASS (tick)
  • 3.32 Check whether the flow count is >= 15 - PASS (tick)
  • 3.33 Check whether all flow status are ADDED - PASS (tick)
  • 3.34 Verify full connectivity for [u'h1', u'h2'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.35 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.36 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.37 Verify full connectivity for [u'olt1', u'vsg1'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.38 Stopping Mininet - PASS (tick)
  • 3.39 Copying karaf logs - PASS (tick)