Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML

<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRLinkFailure-stratum_master_20-builds_graph.jpg", alt="SRLinkFailure-stratum", style="width:525px;height:350px;border:0">

...

Case 1: Bridging and Routing Link Failure test with 2x2 leaf-spine topology and 1 Onos - FAIL

...

  • Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
  • ONOS sees 4 devices (4 expected) and 0 links (8 expected) and 1 controllers (1 expected) and 4 SCCs (1 expected)

...

  • Flow count looks wrong; found 6, expecting at least 116

...

  • Flow status is wrong!

...

  • IP connectivity failed

...

  • IP connectivity failed

...

  • IP connectivity failed

...

  • Topology after link down is incorrect

...

  • IP connectivity failed

...

  • IP connectivity failed

...

  • IP connectivity failed

...

  • Failed to bring link up

...

  • Flow count looks wrong; found 6, expecting at least 116

...

  • Flow status is wrong!

...

  • IP connectivity failed

...

  • IP connectivity failed

...

  • IP connectivity failed

...

Case 2: Bridging and Routing Link Failure test with 4x4 dual-homed leaf-spine topology and 1 Onos - FAIL

...

  • Skipping the rest of this case. 'mininetArgs'

Case 4: Bridging and Routing Link Failure test with 2x2 leaf-spine topology and 3 Onos - FAIL

  • 4.1 Apply cell to environment - PASS (tick)
  • 4.2 Uninstalling Atomix - PASS (tick)
  • 4.3 Uninstalling ONOS package - PASS (tick)
  • 4.4 Building ONOS Docker image - PASS (tick)
  • 4.5 Create Cluster Config - PASS (tick)
  • 4.6 Installing Atomix via docker containers - PASS (tick)
  • 4.7 Installing ONOS via docker containers - PASS (tick)
  • 4.8 Set up ONOS secure SSH - PASS (tick)
  • 4.9 Starting ONOS CLI sessions - PASS (tick)
  • 4.10 Checking ONOS nodes - PASS (tick)
  • 4.11 Checking ONOS applications - PASS (tick)
  • 4.12 Set logging levels - PASS (tick)
  • 4.13 Set ONOS configurations - PASS (tick)
  • 4.14 Starting Mininet Topology - PASS (tick)
  • 4.15 Configure switches in ONOS - PASS (tick)
  • 4.16 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
    • ONOS sees 4 devices (4 expected) and 0 links (8 expected) and 3 controllers (3 expected) and 4 SCCs (1 expected)
  • 4.17 Check whether the flow count is >= 116 - FAIL (error)
    • Flow count looks wrong; found 6, expecting at least 116
  • 4.18 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 4.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 4.20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 4.21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 4.22 Kill link between spine101 and leaf2 - PASS (tick)
  • 4.23 Checking topology after link down - FAIL (error)
    • Topology after link down is incorrect
  • 4.24 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 4.25 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 4.26 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 4.27 Restore link between spine101 and leaf2 - FAIL (error)
    • Failed to bring link up
  • 4.28 Check whether the flow count is >= 116 - FAIL (error)
    • Flow count looks wrong; found 6, expecting at least 116
  • 4.29 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 4.30 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE3_Recovery - FAIL (error)
    • IP connectivity failed
  • 4.31 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Recovery - FAIL (error)
    • IP connectivity failed
  • 4.32 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Recovery - FAIL (error)
    • IP connectivity failed
  • 4.33 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
    • ONOS sees 4 devices (4 expected) and 0 links (8 expected) and 3 controllers (3 expected) and 4 SCCs (1 expected)
  • 4.34 Stopping Mininet - PASS (tick)
  • 4.35 Copying karaf logs - PASS (tick)

Case 5: Bridging and Routing Link Failure test with 4x4 dual-homed leaf-spine topology and 3 Onos - FAIL

...