  • 23.1 Apply cell to environment - PASS (tick)
  • 23.2 Uninstalling ONOS package - PASS (tick)
  • 23.3 Installing ONOS package - PASS (tick)
  • 23.4 Set up ONOS secure SSH - PASS (tick)
  • 23.5 Checking ONOS service - PASS (tick)
  • 23.6 Starting ONOS CLI sessions - PASS (tick)
  • 23.7 Checking ONOS nodes - PASS (tick)
  • 23.8 Checking ONOS applications - PASS (tick)
  • 23.9 Starting Mininet Topology - PASS (tick)
  • 23.10 Check whether the flow count is bigger than 106 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 23.11 Check whether all flow status are ADDED - PASS (tick)
  • 23.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 23.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 23.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 23.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 23.16 Check whether the flow count is bigger than 106 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 23.17 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 23.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS (tick)
  • 23.19 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 23.20 Stopping Mininet - PASS (tick)
  • 23.21 Copying karaf logs - PASS (tick)

Case 33: Changing port configuration from untagged 10 to untagged 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 33.1 Apply cell to environment - PASS (tick)
  • 33.2 Uninstalling ONOS package - PASS (tick)
  • 33.3 Installing ONOS package - PASS (tick)
  • 33.4 Set up ONOS secure SSH - PASS (tick)
  • 33.5 Checking ONOS service - PASS (tick)
  • 33.6 Starting ONOS CLI sessions - PASS (tick)
  • 33.7 Checking ONOS nodes - PASS (tick)
  • 33.8 Checking ONOS applications - PASS (tick)
  • 33.9 Starting Mininet Topology - PASS (tick)
  • 33.10 Check whether the flow count is bigger than 104 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 33.11 Check whether all flow status are ADDED - PASS (tick)
  • 33.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 33.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 33.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 33.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • PASS (tick)
  • 33.16 Check whether the flow count is bigger than 104 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 33.17 Check whether all flow status are ADDED - PASS (tick)
  • 33.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 33.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 33.20 Stopping Mininet - PASS (tick)
  • 33.21 Copying karaf logs - PASS (tick)

Case 43: Changing port configuration from untagged 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 43.1 Apply cell to environment - PASS (tick)
  • 43.2 Uninstalling ONOS package - PASS (tick)
  • 43.3 Installing ONOS package - PASS (tick)
  • 43.4 Set up ONOS secure SSH - PASS (tick)
  • 43.5 Checking ONOS service - PASS (tick)
  • 43.6 Starting ONOS CLI sessions - PASS (tick)
  • 43.7 Checking ONOS nodes - PASS (tick)
  • 43.8 Checking ONOS applications - PASS (tick)
  • 43.9 Starting Mininet Topology - PASS (tick)
  • 43.10 Check whether the flow count is bigger than 104 - PASS (tick)
  • 43.11 Check whether all flow status are ADDED - PASS (tick)
  • 43.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE43_Before - PASS (tick)
  • 43.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_Before - PASS (tick)
  • 43.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 43.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 43.16 Check whether the flow count is bigger than 104 - PASS (tick)
  • 43.17 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 43.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_After - PASS (tick)
  • 43.19 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE43_After - PASS (tick)
  • 43.20 Stopping Mininet - PASS (tick)
  • 43.21 Copying karaf logs - PASS (tick)

...

  • 63.1 Apply cell to environment - PASS (tick)
  • 63.2 Uninstalling ONOS package - PASS (tick)
  • 63.3 Installing ONOS package - PASS (tick)
  • 63.4 Set up ONOS secure SSH - PASS (tick)
  • 63.5 Checking ONOS service - PASS (tick)
  • 63.6 Starting ONOS CLI sessions - PASS (tick)
  • 63.7 Checking ONOS nodes - PASS (tick)
  • 63.8 Checking ONOS applications - PASS (tick)
  • 63.9 Starting Mininet Topology - PASS (tick)
  • 63.10 Check whether the flow count is bigger than 104 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 63.11 Check whether all flow status are ADDED - PASS (tick)
  • 63.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 63.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 63.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 63.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 63.16 Check whether the flow count is bigger than 104 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 63.17 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • PASS (tick)
  • 63.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 63.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 63.20 Stopping Mininet - PASS (tick)
  • 63.21 Copying karaf logs - PASS (tick)

Case 73: Changing port configuration from tagged 10 to untagged 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 73.1 Apply cell to environment - PASS (tick)
  • 73.2 Uninstalling ONOS package - PASS (tick)
  • 73.3 Installing ONOS package - PASS (tick)
  • 73.4 Set up ONOS secure SSH - PASS (tick)
  • 73.5 Checking ONOS service - PASS (tick)
  • 73.6 Starting ONOS CLI sessions - PASS (tick)
  • 73.7 Checking ONOS nodes - PASS (tick)
  • 73.8 Checking ONOS applications - PASS (tick)
  • 73.9 Starting Mininet Topology - PASS (tick)
  • 73.10 Check whether the flow count is bigger than 106 - PASS (tick)- FAIL (error)
    • Flow count looks wrong: False
  • 73.11 Check whether all flow status are ADDED - PASS (tick)
  • 73.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE73_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 73.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE73_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 73.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 73.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 73.16 Check whether the flow count is bigger than 106 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 73.17 Check whether all flow status are ADDED - PASS (tick)
  • 73.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE73_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 73.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE73_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 73.20 Stopping Mininet - PASS (tick)
  • 73.21 Copying karaf logs - PASS (tick)

...

  • 83.1 Apply cell to environment - PASS (tick)
  • 83.2 Uninstalling ONOS package - PASS (tick)
  • 83.3 Installing ONOS package - PASS (tick)
  • 83.4 Set up ONOS secure SSH - PASS (tick)
  • 83.5 Checking ONOS service - PASS (tick)
  • 83.6 Starting ONOS CLI sessions - PASS (tick)
  • 83.7 Checking ONOS nodes - PASS (tick)
  • 83.8 Checking ONOS applications - PASS (tick)
  • 83.9 Starting Mininet Topology - PASS (tick)
  • 83.10 Check whether the flow count is bigger than 104 - PASS (tick)
  • 83.11 Check whether all flow status are ADDED - PASS (tick)
  • 83.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_Before - PASS (tick)
  • 83.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_Before - PASS (tick)
  • 83.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 83.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 83.16 Check whether the flow count is bigger than 104 - PASS (tick)
  • 83.17 Check whether all flow status are ADDED - PASS (tick)
  • 83.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_After - PASS (tick)
  • 83.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_After - PASS (tick)
  • 83.20 Stopping Mininet - PASS (tick)
  • 83.21 Copying karaf logs - PASS (tick)

Case 93: Changing port configuration from tagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 93.1 Apply cell to environment - PASS (tick)
  • 93.2 Uninstalling ONOS package - PASS (tick)
  • 93.3 Installing ONOS package - PASS (tick)
  • 93.4 Set up ONOS secure SSH - PASS (tick)
  • 93.5 Checking ONOS service - PASS (tick)
  • 93.6 Starting ONOS CLI sessions - PASS (tick)
  • 93.7 Checking ONOS nodes - PASS (tick)
  • 93.8 Checking ONOS applications - PASS (tick)
  • 93.9 Starting Mininet Topology - PASS (tick)
  • 93.10 Check whether the flow count is bigger than 106 - PASS (tick)
  • 93.11 Check whether all flow status are ADDED - PASS (tick)
  • 93.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_Before - PASS (tick)
  • 93.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_Before - PASS (tick)
  • 93.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 93.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 93.16 Check whether the flow count is bigger than 106 - PASS (tick)
  • 93.17 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 93.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_After - PASS (tick)
  • 93.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_After - PASS (tick)
  • 93.20 Stopping Mininet - PASS (tick)
  • 93.21 Copying karaf logs - PASS (tick)

...

  • 123.1 Apply cell to environment - PASS (tick)
  • 123.2 Uninstalling ONOS package - PASS (tick)
  • 123.3 Installing ONOS package - PASS (tick)
  • 123.4 Set up ONOS secure SSH - PASS (tick)
  • 123.5 Checking ONOS service - PASS (tick)
  • 123.6 Starting ONOS CLI sessions - PASS (tick)
  • 123.7 Checking ONOS nodes - PASS (tick)
  • 123.8 Checking ONOS applications - PASS (tick)
  • 123.9 Starting Mininet Topology - PASS (tick)
  • 123.10 Check whether the flow count is bigger than 104 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 123.11 Check whether all flow status are ADDED - PASS (tick)
  • 123.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_Before - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 123.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_Before - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 123.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 123.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 123.16 Check whether the flow count is bigger than 104 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 123.17 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 123.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_After - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 123.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_After - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 123.20 Stopping Mininet - PASS (tick)
  • 123.21 Copying karaf logs - PASS (tick)

...

  • 163.1 Apply cell to environment - PASS (tick)
  • 163.2 Uninstalling ONOS package - PASS (tick)
  • 163.3 Installing ONOS package - PASS (tick)
  • 163.4 Set up ONOS secure SSH - PASS (tick)
  • 163.5 Checking ONOS service - PASS (tick)
  • 163.6 Starting ONOS CLI sessions - PASS (tick)
  • 163.7 Checking ONOS nodes - PASS (tick)
  • 163.8 Checking ONOS applications - PASS (tick)
  • 163.9 Starting Mininet Topology - PASS (tick)
  • 163.10 Check whether the flow count is bigger than 106 - PASS (tick)
  • 163.11 Check whether all flow status are ADDED - PASS (tick)
  • 163.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE163_Before - PASS (tick)
  • 163.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_Before - PASS (tick)
  • 163.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 163.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 163.16 Check whether the flow count is bigger than 106 - PASS (tick)
  • 163.17 Check whether all flow status are ADDED - PASS (tick)
  • 163.18 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE163_After - PASS (tick)
  • 163.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_After - PASS (tick)
  • 163.20 Stopping Mininet - PASS (tick)
  • 163.21 Copying karaf logs - PASS (tick)

Case 173: Changing port configuration from tagged 20 to tagged 120, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 173.1 Apply cell to environment - PASS (tick)
  • 173.2 Uninstalling ONOS package - PASS (tick)
  • 173.3 Installing ONOS package - PASS (tick)
  • 173.4 Set up ONOS secure SSH - PASS (tick)
  • 173.5 Checking ONOS service - PASS (tick)
  • 173.6 Starting ONOS CLI sessions - PASS (tick)
  • 173.7 Checking ONOS nodes - PASS (tick)
  • 173.8 Checking ONOS applications - PASS (tick)
  • 173.9 Starting Mininet Topology - PASS (tick)
  • 173.10 Check whether the flow count is bigger than 106 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 173.11 Check whether all flow status are ADDED - PASS (tick)
  • 173.12 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE173_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 173.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE173_Before - PASS (tick)
  • 173.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)53 - FAIL (error)
    • Flow count looks wrong.
  • 173.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 173.16 Check whether the flow count is bigger than 106 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 173.17 Check whether all flow status are ADDED - PASS (tick)
  • 173.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE173_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 173.19 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE173_After - PASS (tick)
  • 173.20 Stopping Mininet - PASS (tick)
  • 173.21 Copying karaf logs - PASS (tick)

...

  • 193.1 Apply cell to environment - PASS (tick)
  • 193.2 Uninstalling ONOS package - PASS (tick)
  • 193.3 Installing ONOS package - PASS (tick)
  • 193.4 Set up ONOS secure SSH - PASS (tick)
  • 193.5 Checking ONOS service - PASS (tick)
  • 193.6 Starting ONOS CLI sessions - PASS (tick)
  • 193.7 Checking ONOS nodes - PASS (tick)
  • 193.8 Checking ONOS applications - PASS (tick)
  • 193.9 Starting Mininet Topology - PASS (tick)
  • 193.10 Check whether the flow count is bigger than 106 - PASS (tick)
  • 193.11 Check whether all flow status are ADDED - PASS (tick)
  • 193.12 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE193_Before - PASS (tick)
  • 193.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE193_Before - PASS (tick)
  • 193.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 193.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 193.16 Check whether the flow count is bigger than 106 - PASS (tick)
  • 193.17 Check whether all flow status are ADDED - PASS (tick)
  • 193.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE193_After - PASS (tick)
  • 193.19 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE193_After - PASS (tick)
  • 193.20 Stopping Mininet - PASS (tick)
  • 193.21 Copying karaf logs - PASS (tick)

Case 203: Changing port configuration from tagged 20 and native 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 203.1 Apply cell to environment - PASS (tick)
  • 203.2 Uninstalling ONOS package - PASS (tick)
  • 203.3 Installing ONOS package - PASS (tick)
  • 203.4 Set up ONOS secure SSH - PASS (tick)
  • 203.5 Checking ONOS service - PASS (tick)
  • 203.6 Starting ONOS CLI sessions - PASS (tick)
  • 203.7 Checking ONOS nodes - PASS (tick)
  • 203.8 Checking ONOS applications - PASS (tick)
  • 203.9 Starting Mininet Topology - PASS (tick)
  • 203.10 Check whether the flow count is bigger than 106 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 203.11 Check whether all flow status are ADDED - PASS (tick)
  • 203.12 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 203.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_Before - PASS (tick)
  • 203.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 203.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 203.16 Check whether the flow count is bigger than 106 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 203.17 Check whether all flow status are ADDED - PASS (tick)
  • 203.18 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 203.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_After - PASS (tick)
  • 203.20 Stopping Mininet - PASS (tick)
  • 203.21 Copying karaf logs - PASS (tick)

...