Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
commit 1990278de6f59d84cd81aebe84135050122b056b (HEAD -] onos-2.0, origin/onos-2.0)
Author: Thomas Vachuska [tom@opennetworking.org]
AuthorDate: Mon Apr 15 09:42:24 2019 -0700
Commit: Thomas Vachuska [tom@opennetworking.org]
CommitDate: Mon Apr 15 09:46:35 2019 -0700
Replaced test mock with existing adapter in archetypes.
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances -
...
PASS
- 5.1 Constructing test variables - PASS
- 5.2 Apply cell to environment - PASS
- 5.3 Uninstalling Atomix - PASS
- 5.4 Uninstalling ONOS package - PASS
- 5.5 Creating ONOS package - PASS
- 5.6 Installing Atomix - PASS
- 5.7 Installing ONOS package - PASS
- 5.8 Set up ONOS secure SSH - PASS
- 5.9 Checking ONOS service - PASS
- 5.10 Starting ONOS CLI sessions - PASS
- 5.11 Checking ONOS nodes - PASS
- 5.12 Checking ONOS applications - PASS
- 5.13 Starting Mininet Topology - PASS
- 5.14 Check whether the flow count is bigger than 28 - FAIL
- Flow count looks wrong: 3
- PASS
- 5.15 Check whether all flow status are ADDED - PASS
- 5.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - FAIL
- Flow count looks wrong: 3
- PASS
- 5.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - FAIL IP connectivity failed
- PASS
- 5.18 Stopping Mininet - PASS
- 5.19 Copying karaf logs - PASS
Case 6: Bridging test between two untagged hosts on vlan-untagged port, with dual-homed ToR and 3 ONOS instances -
...
PASS
- 6.1 Apply cell to environment - PASS
- 6.2 Uninstalling Atomix - PASS
- 6.3 Uninstalling ONOS package - PASS
- 6.4 Installing Atomix - PASS
- 6.5 Installing ONOS package - PASS
- 6.6 Set up ONOS secure SSH - PASS
- 6.7 Checking ONOS service - PASS
- 6.8 Starting ONOS CLI sessions - PASS
- 6.9 Checking ONOS nodes - PASS
- 6.10 Checking ONOS applications - PASS
- 6.11 Starting Mininet Topology - PASS
- 6.12 Check whether the flow count is bigger than 74 - PASS
- 6.13 Check whether all flow status are ADDED - PASS
- 6.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 6.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 6.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - FAIL
- IP connectivity failed
- PASS
- 6.17 Stopping Mininet - PASS
- 6.18 Copying karaf logs - PASS
...
- 55.1 Apply cell to environment - PASS
- 55.2 Uninstalling Atomix - PASS
- 55.3 Uninstalling ONOS package - PASS
- 55.4 Installing Atomix - PASS
- 55.5 Installing ONOS package - PASS
- 55.6 Set up ONOS secure SSH - PASS
- 55.7 Checking ONOS service - PASS
- 55.8 Starting ONOS CLI sessions - PASS
- 55.9 Checking ONOS nodes - PASS
- 55.10 Checking ONOS applications - PASS
- 55.11 Starting Mininet Topology - PASS
- 55.12 Check whether the flow count is bigger than 28 - PASS
- 55.13 Check whether all flow status are ADDED - PASS
- 55.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 55.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE55 - PASS
- 55.16 Stopping Mininet - PASS
- 55.17 Copying karaf logs - PASS
Case 56: Bridging test between two untagged hosts with different vlan id, with dual-homed ToR and 3 ONOS instances -
...
FAIL
- 56.1 Apply cell to environment - PASS
- 56.2 Uninstalling Atomix - PASS
- 56.3 Uninstalling ONOS package - PASS
- 56.4 Installing Atomix - PASS
- 56.5 Installing ONOS package - PASS
- 56.6 Set up ONOS secure SSH - PASS
- 56.7 Checking ONOS service - PASS
- 56.8 Starting ONOS CLI sessions - PASS
- 56.9 Checking ONOS nodes - PASS
- 56.10 Checking ONOS applications - PASS
- 56.11 Starting Mininet Topology - PASS
- 56.12 Check whether the flow count is bigger than 74 - PASS FAIL
- Flow count looks wrong: 6
- 56.13 Check whether all flow status are ADDED - PASS
- 56.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS FAIL
- Flow count looks wrong: 3
- 56.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS FAIL
- Flow count looks wrong: 3
- 56.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE56 - PASS
- 56.17 Stopping Mininet - PASS
- 56.18 Copying karaf logs - PASS
...