You will see that ONOS will reroute the the traffic as shown in the figure.
LINC Cheat Sheet
You can attach to the console of a running LINC instance as follows:
Code Block | ||
---|---|---|
| ||
$ sudo linc-oe/rel/linc/bin/linc attach |
In the LINC console, the following commands are available. Please note that Erlang is very picky regarding syntax, so make sure you are not missing any spaces or the dot ('.') at the end of each command!
Command | Description |
---|---|
| Get running config |
linc_logic:get_datapath_id(SwitchId). | Get DPID of logical switch |
linc:stop_switch(SwitchId). | Stop logical switch |
| Disable port |
linc:port_up(SwitchId, PortId). | Enable port |
linc:ports(SwitchId). | List ports on logical switch |
linc_us4_oe_flow:get_flow_table(switchId, tableId). | Get flow table of logical switch (use tableId 0) |
Demo 5: Link recovery from packet layer failures
...
We highly encourage you to run that topology and play with it and give us you your feedback.
Resetting and getting out of trouble.
If you wan want to reset Mininet or ONOS, or just want to get out of trouble, do the followingsfollowing.
For resetting Mininet and linc-oe just double click on 'Reset' (terminal icon) on Desktop or type following in mininet console,
...