Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://onos-jenkins.onlab.usonosproject.org/view/QA/job/Pipeline_postjob_BM-Fabric4/lastSuccessfulBuild/artifact/SRSwitchFailure_master_20-builds_graph.jpg", alt="SRSwitchFailure", style="width:525px;height:350px;border:0"> |
commit c29f74827d1f6650620335c1ce5a7e9f5c6a5b6e b53d626fb03195129c0ec0802e1f953f85dcbef8 (HEAD -] master, origin/master, origin/HEAD, master)
Author: Ray Milkey pierventre [ray@opennetworkingpier@opennetworking.org]
AuthorDate: Fri Dec 22 16Wed Sep 22 11:24:38 :08 2017 2021 +00000200
Commit: Ray Milkey [ray@opennetworkingPier Luigi Ventre [pier@opennetworking.org]
CommitDate: Fri Dec 22 19:22:05 2017 +0000
Revert "Bump up buck version"Thu Sep 23 07:38:36 2021 +0000
[SDFAB-612] Cluster not ready when using recent tost master images
--
This reverts commit e743babd01c5cbfc3f580a4c77993bc7047d0846.
Change-Id: Ida34fc6fb6faba624b93b9b01a98e9f5d2bb4d33
...
(cherry picked from commit ec0e942320ef27932b4173172055151015261d7c)
Case 1: Switch Failure test with 2x2 leaf-spine topology and 1 Onos - PASS
- 1.1 Constructing test variables - PASS
- 1.2 Apply cell to environment - PASS
- 1.3 Uninstalling Atomix - PASS
- 1.4 Uninstalling ONOS package - PASS
- 1.5 Creating ONOS package - PASS
- 1.6 Installing Atomix - PASS
- 1.7 Installing ONOS package - PASS
- 1.8 Set up ONOS secure SSH - PASS
- 1.9 Checking ONOS service - PASS
- 1.10 Starting ONOS CLI sessions - PASS
- 1.11 Checking ONOS nodes - PASS
- 1.12 Checking ONOS applications - PASS
- 1.13 Set logging levels - PASS
- 1.14 Set ONOS configurations - PASS
- 1.15 Starting Mininet Topology - PASS
- 1.16 Check whether the flow count is >= 116 - PASS
- 1.17 Check whether all flow status are ADDED - PASS
- 1.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - PASS
- 1.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS
- 1.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS
- 1.21 Kill ['spine101'] - PASS
- 1.22 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - PASS
- 1.23 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - PASS
- 1.24 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - PASS
- 1.25 Recovering ['spine101'] - PASS
- 1.26 Check whether the flow count is >= 116 - PASS
- 1.27 Check whether all flow status are ADDED - PASS
- 1.28 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Recovery - PASS
- 1.29 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Recovery - PASS
- 1.30 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Recovery - PASS
- 1.31 Stopping Mininet - PASS
- 1.32 Copying karaf logs - PASS