Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-1.13/202/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRSwitchFailure_onos-1.13_20-builds_graph.jpg", alt="SRSwitchFailure", style="width:525px;height:350px;border:0">

commit 248e7cd94b80596dc2f4b41a93fb985e811ce411 8d6edf3216f7bce64b92852ce8e4efd2be46dcd9 (HEAD -] onos-1.13, origin/onos-1.13)
Author: Jonathan Hart [jono@opennetworking.orgsnehaprem [sneha.prem@infosys.com]
AuthorDate: Tue Aug 21 17:53:02 2018 -0700Thu Nov 1 01:02:21 2018 -0400
Commit: Jonathan Hart Charles Chan [jono@opennetworkingcharles@opennetworking.org]
CommitDate: Thu Aug 23 00:35:30 2018 +0000
Allow LLDP traps to be installed on OLTsFri Nov 2 06:12:21 2018 +0000

route-remove cli command with source type addition
--
(cherry picked from commit 7828d01ca571190c1c3ba526dd24ef6e7399c79c)

Case 1: Switch Failure test with 2x2 Leaf-spine and 1 Onos - FAIL

...

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling ONOS package - PASS (tick)
  • 1.4 Creating ONOS package - PASS (tick)
  • 1.5 Installing ONOS package - PASS (tick)
  • 1.6 Set up ONOS secure SSH - PASS (tick)
  • 1.7 Checking ONOS service - PASS (tick)
  • 1.8 Starting ONOS CLI sessions - PASS (tick)
  • 1.9 Checking ONOS nodes - PASS (tick)
  • 1.10 Checking ONOS applications - PASS (tick)
  • 1.11 Starting Mininet Topology - PASS (tick)
  • 1.12 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.13 Check whether all flow status are ADDED - PASS (tick)
  • 1.14 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.15 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS (tick)
  • 1.16 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS (tick)
  • 1.17 Kill ['spine101'] - FAIL (error)
    • Failed to kill switch?
  • PASS (tick)
  • 1.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - PASS (tick)
  • 1.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - PASS (tick)
  • 1.21 Recovering ['spine101'] - FAIL (error)
    • Failed to recover switch?
  • 1.22 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.23 Check whether all flow status are ADDED - PASS (tick)
  • 1.24 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.25 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Recovery - PASS (tick)
  • 1.26 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Recovery - PASS (tick)
  • 1.27 Stopping Mininet - PASS (tick)
  • 1.28 Copying karaf logs - PASS (tick)

...

  • 5.1 Apply cell to environment - PASS (tick)
  • 5.2 Uninstalling ONOS package - PASS (tick)
  • 5.3 Creating ONOS package - PASS (tick)
  • 5.4 Installing ONOS package - PASS (tick)
  • 5.5 Set up ONOS secure SSH - PASS (tick)
  • 5.6 Checking ONOS service - PASS (tick)
  • 5.7 Starting ONOS CLI sessions - PASS (tick)
  • 5.8 Checking ONOS nodes - PASS (tick)
  • 5.9 Checking ONOS applications - PASS (tick)
  • 5.10 Starting Mininet Topology - PASS (tick)
  • 5.11 Check whether the flow count is bigger than 350 - PASS (tick)
  • 5.12 Check whether all flow status are ADDED - PASS (tick)
  • 5.13 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.14 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5 - PASS (tick)
  • 5.15 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5 - PASS (tick)
  • 5.16 Kill ['spine101'] - PASS (tick)FAIL (error)
    • Failed to kill switch?
  • 5.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5_Failure - FAIL (error)
    • IP connectivity failed
  • 5.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5_Failure - PASS (tick)
  • 5.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5_Failure - PASS (tick)
  • 5.20 Recovering ['spine101'] - FAIL (error)
    • Failed to recover switch?
  • 5.21 Check whether the flow count is bigger than 350 - PASS (tick)
  • 5.22 Check whether all flow status are ADDED - PASS (tick)
  • 5.23 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5_Recovery - FAIL (error)
    • IP connectivity failed
  • 5.24 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5_Recovery - PASS (tick)
  • 5.25 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5_Recovery - PASS (tick)
  • 5.26 Stopping Mininet - PASS (tick)
  • 5.27 Copying karaf logs - PASS (tick)