Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRBridging_onos-2.2_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit 70782fc05fab40e77134fdc460f1613394528246 90613fc8b563f96866f390f3c47f857c79344972 (HEAD -] onos-2.2, origin/onos-2.2)
Author: pierventre Jian Li [pier@opennetworkingpyguni@gmail.orgcom]
AuthorDate: Wed Apr 21 12:57:47 2021 +0200Thu Aug 26 22:04:08 2021 +0900
Commit: Pier Luigi Ventre [pier@opennetworking.orgJian Li [pyguni@gmail.com]
CommitDate: Fri Apr 30 04Thu Aug 26 22:20:33 :23 2021 +0000
[AETHER-1550] Add additional trace logs in P4RT SB0900

Fix: use k8s API config IP address as the controller's IP

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, ovs switches and 3 ONOS instances - FAIL

...

  • 5.1 Constructing test variables - PASS (tick)
  • 5.2 Apply cell to environment - PASS (tick)
  • 5.3 Uninstalling Atomix - PASS (tick)
  • 5.4 Uninstalling ONOS package - PASS (tick)
  • 5.5 Creating ONOS package - PASS (tick)
  • 5.6 Installing Atomix - PASS (tick)
  • 5.7 Installing ONOS package - PASS (tick)
  • 5.8 Set up ONOS secure SSH - PASS (tick)
  • 5.9 Checking ONOS service - PASS (tick)
  • 5.10 Starting ONOS CLI sessions - PASS (tick)
  • 5.11 Checking ONOS nodes - PASS (tick)
  • 5.12 Checking ONOS applications - PASS (tick)
  • 5.13 Set logging levels - PASS (tick)
  • 5.14 Set ONOS configurations - PASS (tick)
  • 5.15 Starting Mininet Topology - PASS (tick)
  • 5.16 Check whether the flow count is >= 28 - FAIL (error)
    • Flow count looks wrong; found 1718, expecting at least 28
  • 5.17 Check whether all flow status are ADDED - PASS (tick)
  • 5.18 Check whether the flow count of device of:0000000000000001 >= than 28 - FAIL (error)
    • Flow count looks wrong: 1718
  • 5.19 Check number of topology elements - PASS (tick)
  • 5.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.21 Stopping Mininet - PASS (tick)
  • 5.22 Copying karaf logs - PASS (tick)

...

  • 6.1 Apply cell to environment - PASS (tick)
  • 6.2 Uninstalling Atomix - PASS (tick)
  • 6.3 Uninstalling ONOS package - PASS (tick)
  • 6.4 Installing Atomix - PASS (tick)
  • 6.5 Installing ONOS package - PASS (tick)
  • 6.6 Set up ONOS secure SSH - PASS (tick)
  • 6.7 Checking ONOS service - PASS (tick)
  • 6.8 Starting ONOS CLI sessions - PASS (tick)
  • 6.9 Checking ONOS nodes - PASS (tick)
  • 6.10 Checking ONOS applications - PASS (tick)
  • 6.11 Set logging levels - PASS (tick)
  • 6.12 Set ONOS configurations - PASS (tick)
  • 6.13 Starting Mininet Topology - PASS (tick)
  • 6.14 Check whether the flow count is >= 74 - PASS (tick)
  • 6.15 Check whether all flow status are ADDED - PASS (tick)
  • 6.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS (tick)
  • 6.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 17
  • 6.18 Check number of topology elements - PASS (tick)
  • 6.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - FAIL (error)
    • IP connectivity failed
  • 6.20 Stopping Mininet - PASS (tick)
  • 6.21 Copying karaf logs - PASS (tick)

...

  • 18.1 Apply cell to environment - PASS (tick)
  • 18.2 Uninstalling Atomix - PASS (tick)
  • 18.3 Uninstalling ONOS package - PASS (tick)
  • 18.4 Installing Atomix - PASS (tick)
  • 18.5 Installing ONOS package - PASS (tick)
  • 18.6 Set up ONOS secure SSH - PASS (tick)
  • 18.7 Checking ONOS service - PASS (tick)
  • 18.8 Starting ONOS CLI sessions - PASS (tick)
  • 18.9 Checking ONOS nodes - PASS (tick)
  • 18.10 Checking ONOS applications - PASS (tick)
  • 18.11 Set logging levels - PASS (tick)
  • 18.12 Set ONOS configurations - PASS (tick)
  • 18.13 Starting Mininet Topology - PASS (tick)
  • 18.14 Check whether the flow count is >= 212 - PASS (tick)
  • 18.15 Check whether all flow status are ADDED - PASS (tick)
  • 18.16 Check whether the flow count of device of:0000000000000001 >= than 53 - PASS (tick)
  • 18.17 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS (tick)
  • 18.18 Check whether the flow count of device of:0000000000000003 >= than 53 - PASS (tick)
  • 18.19 Check whether the flow count of device of:0000000000000004 >= than 53 - PASS (tick)
  • 18.20 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
    • ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
  • 18.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS (tick)
  • 18.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS (tick)
  • 18.23 Stopping Mininet - PASS (tick)
  • 18.24 Copying karaf logs - PASS (tick)

Case 25: Bridging test between two untagged hosts on vlan-native port, with single ToR, ovs switches and 3 ONOS instances -

...

PASS

  • 25.1 Apply cell to environment - PASS (tick)
  • 25.2 Uninstalling Atomix - PASS (tick)
  • 25.3 Uninstalling ONOS package - PASS (tick)
  • 25.4 Installing Atomix - PASS (tick)
  • 25.5 Installing ONOS package - PASS (tick)
  • 25.6 Set up ONOS secure SSH - PASS (tick)
  • 25.7 Checking ONOS service - PASS (tick)
  • 25.8 Starting ONOS CLI sessions - PASS (tick)
  • 25.9 Checking ONOS nodes - PASS (tick)
  • 25.10 Checking ONOS applications - PASS (tick)
  • 25.11 Set logging levels - PASS (tick)
  • 25.12 Set ONOS configurations - PASS (tick)
  • 25.13 Starting Mininet Topology - PASS (tick)
  • 25.14 Check whether the flow count is >= 28 - FAIL (error)
    • Flow count looks wrong; found 17, expecting at least 28
  • PASS (tick)
  • 25 25.15 Check whether all flow status are ADDED - PASS (tick)
  • 25.16 Check whether the flow count of device of:0000000000000001 >= than 28 - FAIL (error)
    • Flow count looks wrong: 17
  • PASS (tick)
  • 25.17 Check number of topology elements - PASS (tick)
  • 25.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE25 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 25.19 Stopping Mininet - PASS (tick)
  • 25.20 Copying karaf logs - PASS (tick)

...

  • 26.1 Apply cell to environment - PASS (tick)
  • 26.2 Uninstalling Atomix - PASS (tick)
  • 26.3 Uninstalling ONOS package - PASS (tick)
  • 26.4 Installing Atomix - PASS (tick)
  • 26.5 Installing ONOS package - PASS (tick)
  • 26.6 Set up ONOS secure SSH - PASS (tick)
  • 26.7 Checking ONOS service - PASS (tick)
  • 26.8 Starting ONOS CLI sessions - PASS (tick)
  • 26.9 Checking ONOS nodes - PASS (tick)
  • 26.10 Checking ONOS applications - PASS (tick)
  • 26.11 Set logging levels - PASS (tick)
  • 26.12 Set ONOS configurations - PASS (tick)
  • 26.13 Starting Mininet Topology - PASS (tick)
  • 26.14 Check whether the flow count is >= 74 - PASS (tick)
  • 26.15 Check whether all flow status are ADDED - PASS (tick)
  • 26.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS (tick)
  • 26.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS (tick)
  • 26.18 Check number of topology elements - PASS (tick)
  • 26.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE26 - PASS (tick)
  • 26.20 Stopping Mininet - PASS (tick)
  • 26.21 Copying karaf logs - PASS (tick)

Case 27: Bridging test between two untagged hosts on vlan-native port, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -

...

PASS

  • 27.1 Apply cell to environment - PASS (tick)
  • 27.2 Uninstalling Atomix - PASS (tick)
  • 27.3 Uninstalling ONOS package - PASS (tick)
  • 27.4 Installing Atomix - PASS (tick)
  • 27.5 Installing ONOS package - PASS (tick)
  • 27.6 Set up ONOS secure SSH - PASS (tick)
  • 27.7 Checking ONOS service - PASS (tick)
  • 27.8 Starting ONOS CLI sessions - PASS (tick)
  • 27.9 Checking ONOS nodes - PASS (tick)
  • 27.10 Checking ONOS applications - PASS (tick)
  • 27.11 Set logging levels - PASS (tick)
  • 27.12 Set ONOS configurations - PASS (tick)
  • 27.13 Starting Mininet Topology - PASS (tick)
  • 27.14 Check whether the flow count is >= 74 - FAIL (error)
  • Flow count looks wrong; found 68, expecting at least 74
  • PASS (tick)
  • 27.15 Check whether all flow status are ADDED - PASS (tick)
  • 27.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL (error)
    • Flow count looks wrong: 17
  • PASS (tick)
  • 27.17 Check whether the flow count of device of:0000000000000002 >= than 37 - FAIL (error)
    • Flow count looks wrong: 17
  • PASS (tick)
  • 27.18 Check number of topology elements - PASS (tick)
  • 27.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 27.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 27.21 Stopping Mininet - PASS (tick)
  • 27.22 Copying karaf logs - PASS (tick)

...

  • 28.1 Apply cell to environment - PASS (tick)
  • 28.2 Uninstalling Atomix - PASS (tick)
  • 28.3 Uninstalling ONOS package - PASS (tick)
  • 28.4 Installing Atomix - PASS (tick)
  • 28.5 Installing ONOS package - PASS (tick)
  • 28.6 Set up ONOS secure SSH - PASS (tick)
  • 28.7 Checking ONOS service - PASS (tick)
  • 28.8 Starting ONOS CLI sessions - PASS (tick)
  • 28.9 Checking ONOS nodes - PASS (tick)
  • 28.10 Checking ONOS applications - PASS (tick)
  • 28.11 Set logging levels - PASS (tick)
  • 28.12 Set ONOS configurations - PASS (tick)
  • 28.13 Starting Mininet Topology - PASS (tick)
  • 28.14 Check whether the flow count is >= 212 - PASS (tick)FAIL (error)
    • Flow count looks wrong; found 108, expecting at least 212
  • 28.15 Check whether 28.15 Check whether all flow status are ADDED - PASS (tick)
  • 28.16 Check whether the flow count of device of:0000000000000001 >= than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 18
  • 28.17 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 18
  • 28.18 Check whether the flow count of device of:0000000000000003 >= than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 18
  • 28.19 Check whether the flow count of device of:0000000000000004 >= than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 18
  • 28.20 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
    • ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
  • 28.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE28 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 28.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE28 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 28.23 Stopping Mininet - PASS (tick)
  • 28.24 Copying karaf logs - PASS (tick)

Case 35: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with single ToR, ovs switches and 3 ONOS instances -

...

PASS

  • 35.1 Apply cell to environment - PASS (tick)
  • 35.2 Uninstalling Atomix - PASS (tick)
  • 35.3 Uninstalling ONOS package - PASS (tick)
  • 35.4 Installing Atomix - PASS (tick)
  • 35.5 Installing ONOS package - PASS (tick)
  • 35.6 Set up ONOS secure SSH - PASS (tick)
  • 35.7 Checking ONOS service - PASS (tick)
  • 35.8 Starting ONOS CLI sessions - PASS (tick)
  • 35.9 Checking ONOS nodes - PASS (tick)
  • 35.10 Checking ONOS applications - PASS (tick)
  • 35.11 Set logging levels - PASS (tick)
  • 35.12 Set ONOS configurations - PASS (tick)
  • 35.13 Starting Mininet Topology - PASS (tick)
  • 35.14 Check whether the flow count is >= 28 - FAIL (error)
    • Flow count looks wrong; found 17, expecting at least 28
  • PASS (tick)
  • 35.15 Check whether all flow status are ADDED - PASS (tick)
  • 35.16 Check whether the flow count of device of:0000000000000001 >= than 28 - FAIL (error)
    • Flow count looks wrong: 17
  • PASS (tick)
  • 35.17 Check number of topology elements - PASS (tick)
  • 35.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE35 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 35.19 Stopping Mininet - PASS (tick)
  • 35.20 Copying karaf logs - PASS (tick)

Case 36: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with dual-homed ToR, ovs switches and 3 ONOS instances -

...

PASS

  • 36.1 Apply cell to environment - PASS (tick)
  • 36.2 Uninstalling Atomix - PASS (tick)
  • 36.3 Uninstalling ONOS package - PASS (tick)
  • 36.4 Installing Atomix - PASS (tick)
  • 36.5 Installing ONOS package - PASS (tick)
  • 36.6 Set up ONOS secure SSH - PASS (tick)
  • 36.7 Checking ONOS service - PASS (tick)
  • 36.8 Starting ONOS CLI sessions - PASS (tick)
  • 36.9 Checking ONOS nodes - PASS (tick)
  • 36.10 Checking ONOS applications - PASS (tick)
  • 36.11 Set logging levels - PASS (tick)
  • 36.12 Set ONOS configurations - PASS (tick)
  • 36.13 Starting Mininet Topology - PASS (tick)
  • 36.14 Check whether the flow count is >= 74 - FAIL (error)
  • Flow count looks wrong; found 36, expecting at least 74
  • count is >= 74 - PASS (tick)
  • 36.15 Check whether all flow status are ADDED - PASS (tick)
  • 36.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL (error)
  • Flow count looks wrong: 18
  • PASS (tick)
  • 36.17 Check whether the flow count of device of:0000000000000002 >= than 37 - FAIL (error)
    • Flow count looks wrong: 18
  • PASS (tick)
  • 36.18 Check number of topology elements - PASS (tick)
  • 36.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE36 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 36.20 Stopping Mininet - PASS (tick)
  • 36.21 Copying karaf logs - PASS (tick)

Case 37: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -

...

FAIL

  • 37.1 Apply cell to environment - PASS (tick)
  • 37.2 Uninstalling Atomix - PASS (tick)
  • 37.3 Uninstalling ONOS package - PASS (tick)
  • 37.4 Installing Atomix - PASS (tick)
  • 37.5 Installing ONOS package - PASS (tick)
  • 37.6 Set up ONOS secure SSH - PASS (tick)
  • 37.7 Checking ONOS service - PASS (tick)
  • 37.8 Starting ONOS CLI sessions - PASS (tick)
  • 37.9 Checking ONOS nodes - PASS (tick)
  • 37.10 Checking ONOS applications - PASS (tick)
  • 37.11 Set logging levels - PASS (tick)
  • 37.12 Set ONOS configurations - PASS (tick)
  • 37.13 Starting Mininet Topology - PASS (tick)
  • 37.14 Check whether the flow count is >= 74 - PASS (tick)
  • 37.15 Check whether all flow status are ADDED - PASS (tick)
  • 37.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS (tick)
  • 37.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS (tick)
  • 37.18 Check number of topology elements - PASS (tick)
  • 37.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 37.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - PASS (tick)
  • 37.21 Stopping Mininet - PASS (tick)
  • 37.22 Copying karaf logs - PASS (tick)

...

  • 45.1 Apply cell to environment - PASS (tick)
  • 45.2 Uninstalling Atomix - PASS (tick)
  • 45.3 Uninstalling ONOS package - PASS (tick)
  • 45.4 Installing Atomix - PASS (tick)
  • 45.5 Installing ONOS package - PASS (tick)
  • 45.6 Set up ONOS secure SSH - PASS (tick)
  • 45.7 Checking ONOS service - PASS (tick)
  • 45.8 Starting ONOS CLI sessions - PASS (tick)
  • 45.9 Checking ONOS nodes - PASS (tick)
  • 45.10 Checking ONOS applications - PASS (tick)
  • 45.11 Set logging levels - PASS (tick)
  • 45.12 Set ONOS configurations - PASS (tick)
  • 45.13 Starting Mininet Topology - PASS (tick)
  • 45.14 Check whether the flow count is >= 28 - PASS (tick)
  • 45.15 Check whether all flow status are ADDED - PASS (tick)
  • 45.16 Check whether the flow count of device of:0000000000000001 >= than 28 - PASS (tick)
  • 45.17 Check number of topology elements - PASS (tick)
  • 45.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE45 - PASS (tick)
  • 45.19 Stopping Mininet - PASS (tick)
  • 45.20 Copying karaf logs - PASS (tick)

Case 46: Bridging test between untagged host and tagged host, with dual-homed ToR, ovs switches and 3 ONOS instances -

...

FAIL

  • 46.1 Apply cell to environment - PASS (tick)
  • 46.2 Uninstalling Atomix - PASS (tick)
  • 46.3 Uninstalling ONOS package - PASS (tick)
  • 46.4 Installing Atomix - PASS (tick)
  • 46.5 Installing ONOS package - PASS (tick)
  • 46.6 Set up ONOS secure SSH - PASS (tick)
  • 46.7 Checking ONOS service - PASS (tick)
  • 46.8 Starting ONOS CLI sessions - PASS (tick)
  • 46.9 Checking ONOS nodes - PASS (tick)
  • 46.10 Checking ONOS applications - PASS (tick)
  • 46.11 Set logging levels - PASS (tick)
  • 46.12 Set ONOS configurations - PASS (tick)
  • 46.13 Starting Mininet Topology - PASS (tick)
  • 46.14 Check whether the flow count is >= 74 - PASS (tick)FAIL (error)
    • Flow count looks wrong; found 34, expecting at least 74
  • 46.15 Check whether all flow status are ADDED - PASS (tick)
  • 46.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 17
  • 46.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 17
  • 46.18 Check number of topology elements - PASS (tick)
  • 46.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 46.20 Stopping Mininet - PASS (tick)
  • 46.21 Copying karaf logs - PASS (tick)

Case 47: Bridging test between untagged host and tagged host, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -

...

PASS

  • 47.1 Apply cell to environment - PASS (tick)
  • 47.2 Uninstalling Atomix - PASS (tick)
  • 47.3 Uninstalling ONOS package - PASS (tick)
  • 47.4 Installing Atomix - PASS (tick)
  • 47.5 Installing ONOS package - PASS (tick)
  • 47.6 Set up ONOS secure SSH - PASS (tick)
  • 47.7 Checking ONOS service - PASS (tick)
  • 47.8 Starting ONOS CLI sessions - PASS (tick)
  • 47.9 Checking ONOS nodes - PASS (tick)
  • 47.10 Checking ONOS applications - PASS (tick)
  • 47.11 Set logging levels - PASS (tick)
  • 47.12 Set ONOS configurations - PASS (tick)
  • 47.13 Starting Mininet Topology - PASS (tick)
  • 47.14 Check whether the flow count is >= 74 - FAIL (error)
  • Flow count looks wrong; found 72, expecting at least 74
  • PASS (tick)
  • 47.15 Check whether all flow status are ADDED - PASS (tick)
  • 47.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL (error)
  • Flow count looks wrong: 18
  • PASS (tick)
  • 47.17 Check whether the flow count of device of:0000000000000002 >= than 37 - FAIL (error)
  • Flow count looks wrong: 18
  • PASS (tick)
  • 47.18 Check number of topology elements - PASS (tick)
  • 47.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 47.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 47.21 Stopping Mininet - PASS (tick)
  • 47.22 Copying karaf logs - PASS (tick)

...

  • 48.1 Apply cell to environment - PASS (tick)
  • 48.2 Uninstalling Atomix - PASS (tick)
  • 48.3 Uninstalling ONOS package - PASS (tick)
  • 48.4 Installing Atomix - PASS (tick)
  • 48.5 Installing ONOS package - PASS (tick)
  • 48.6 Set up ONOS secure SSH - PASS (tick)
  • 48.7 Checking ONOS service - PASS (tick)
  • 48.8 Starting ONOS CLI sessions - PASS (tick)
  • 48.9 Checking ONOS nodes - PASS (tick)
  • 48.10 Checking ONOS applications - PASS (tick)
  • 48.11 Set logging levels - PASS (tick)
  • 48.12 Set ONOS configurations - PASS (tick)
  • 48.13 Starting Mininet Topology - PASS (tick)
  • 48.14 Check whether the flow count is >= 212 - PASS (tick)FAIL (error)
    • Flow count looks wrong; found 102, expecting at least 212
  • 48.15 Check whether all flow status are ADDED - PASS (tick)
  • 48.16 Check whether the flow count of device of:0000000000000001 >= than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 17
  • 48.17 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 17
  • 48.18 Check whether the flow count of device of:0000000000000003 >= than 53 - PASS (tick)- FAIL (error)
    • Flow count looks wrong: 17
  • 48.19 Check whether the flow count of device of:0000000000000004 >= than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 17
  • 48.20 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
    • ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
  • 48.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE48 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 48.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE48 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 48.23 Stopping Mininet - PASS (tick)
  • 48.24 Copying karaf logs - PASS (tick)

Case 55: Bridging test between two untagged hosts with different vlan id, with single ToR, ovs switches and 3 ONOS instances -

...

FAIL

  • 55.1 Apply cell to environment - PASS (tick)
  • 55.2 Uninstalling Atomix - PASS (tick)
  • 55.3 Uninstalling ONOS package - PASS (tick)
  • 55.4 Installing Atomix - PASS (tick)
  • 55.5 Installing ONOS package - PASS (tick)
  • 55.6 Set up ONOS secure SSH - PASS (tick)
  • 55.7 Checking ONOS service - PASS (tick)
  • 55.8 Starting ONOS CLI sessions - PASS (tick)
  • 55.9 Checking ONOS nodes - PASS (tick)
  • 55.10 Checking ONOS applications - PASS (tick)
  • 55.11 Set logging levels - PASS (tick)
  • 55.12 Set ONOS configurations - PASS (tick)
  • 55.13 Starting Mininet Topology - PASS (tick)
  • 55.14 Check whether the flow count is >= 28 - PASS (tick)FAIL (error)
    • Flow count looks wrong; found 18, expecting at least 28
  • 55.15 Check whether all flow status are ADDED - PASS (tick)
  • 55.16 Check whether the flow count of device of:0000000000000001 >= than 28 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 18
  • 55.17 Check number of topology elements - PASS (tick)
  • 55.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE55 - PASS (tick)
  • 55.19 Stopping Mininet - PASS (tick)
  • 55.20 Copying karaf logs - PASS (tick)

...

  • 56.1 Apply cell to environment - PASS (tick)
  • 56.2 Uninstalling Atomix - PASS (tick)
  • 56.3 Uninstalling ONOS package - PASS (tick)
  • 56.4 Installing Atomix - PASS (tick)
  • 56.5 Installing ONOS package - PASS (tick)
  • 56.6 Set up ONOS secure SSH - PASS (tick)
  • 56.7 Checking ONOS service - PASS (tick)
  • 56.8 Starting ONOS CLI sessions - PASS (tick)
  • 56.9 Checking ONOS nodes - PASS (tick)
  • 56.10 Checking ONOS applications - PASS (tick)
  • 56.11 Set logging levels - PASS (tick)
  • 56.12 Set ONOS configurations - PASS (tick)
  • 56.13 Starting Mininet Topology - PASS (tick)
  • 56.14 Check whether the flow count is >= 74 - FAIL (error)
    • Flow count looks wrong; found 36, expecting at least 74
  • 56.15 Check whether all flow status are ADDED - PASS (tick)
  • 56.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL (error)
    • Flow count looks wrong: 18
  • 56.17 Check whether the flow count of device of:0000000000000002 >= than 37 - FAIL (error)
    • Flow count looks wrong: 18
  • 56.18 Check number of topology elements - PASS (tick)
  • 56.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE56 - PASS (tick)
  • 56.20 Stopping Mininet - PASS (tick)
  • 56.21 Copying karaf logs - PASS (tick)

Case 57: Bridging test between two untagged hosts with different vlan id, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -

...

PASS

  • 57.1 Apply cell to environment - PASS (tick)
  • 57.2 Uninstalling Atomix - PASS (tick)
  • 57.3 Uninstalling ONOS package - PASS (tick)
  • 57.4 Installing Atomix - PASS (tick)
  • 57.5 Installing ONOS package - PASS (tick)
  • 57.6 Set up ONOS secure SSH - PASS (tick)
  • 57.7 Checking ONOS service - PASS (tick)
  • 57.8 Starting ONOS CLI sessions - PASS (tick)
  • 57.9 Checking ONOS nodes - PASS (tick)
  • 57.10 Checking ONOS applications - PASS (tick)
  • 57.11 Set logging levels - PASS (tick)
  • 57.12 Set ONOS configurations - PASS (tick)
  • 57.13 Starting Mininet Topology - PASS (tick)
  • 57.14 Check whether the flow count is >= 74 - FAIL (error)
  • Flow count looks wrong; found 72, expecting at least 74
  • PASS (tick)
  • 57.15 Check whether all flow status are ADDED - PASS (tick)
  • 57.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL (error)
  • Flow count looks wrong: 18
  • PASS (tick)
  • 57.17 Check whether the flow count of device of:0000000000000002 >= than 37 - FAIL (error)
  • Flow count looks wrong: 18
  • PASS (tick)
  • 57.18 Check number of topology elements - PASS (tick)
  • 57.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE57 - PASS (tick)
  • 57.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE57 - PASS (tick)
  • 57.21 Stopping Mininet - PASS (tick)
  • 57.22 Copying karaf logs - PASS (tick)

...

  • 68.1 Apply cell to environment - PASS (tick)
  • 68.2 Uninstalling Atomix - PASS (tick)
  • 68.3 Uninstalling ONOS package - PASS (tick)
  • 68.4 Installing Atomix - PASS (tick)
  • 68.5 Installing ONOS package - PASS (tick)
  • 68.6 Set up ONOS secure SSH - PASS (tick)
  • 68.7 Checking ONOS service - PASS (tick)
  • 68.8 Starting ONOS CLI sessions - PASS (tick)
  • 68.9 Checking ONOS nodes - PASS (tick)
  • 68.10 Checking ONOS applications - PASS (tick)
  • 68.11 Set logging levels - PASS (tick)
  • 68.12 Set ONOS configurations - PASS (tick)
  • 68.13 Starting Mininet Topology - PASS (tick)
  • 68.14 Check whether the flow count is >= 212 - PASS (tick)
  • 68.15 Check whether all flow status are ADDED - PASS (tick)
  • 68.16 Check whether the flow count of device of:0000000000000001 >= than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 21
  • 68.17 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS (tick)
  • 68.18 Check whether the flow count of device of:0000000000000003 >= than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 18
  • 68.19 Check whether the flow count of device of:0000000000000004 >= than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 18
  • 68.20 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
    • ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
  • 68.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE68 - PASS (tick)
  • 68.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE68 - PASS (tick)
  • 68.23 Stopping Mininet - PASS (tick)
  • 68.24 Copying karaf logs - PASS (tick)

Case 75: Bridging test between untagged and tagged hosts with different vlan id, with single ToR, ovs switches and 3 ONOS instances -

...

FAIL

  • 75.1 Apply cell to environment - PASS (tick)
  • 75.2 Uninstalling Atomix - PASS (tick)
  • 75.3 Uninstalling ONOS package - PASS (tick)
  • 75.4 Installing Atomix - PASS (tick)
  • 75.5 Installing ONOS package - PASS (tick)
  • 75.6 Set up ONOS secure SSH - PASS (tick)
  • 75.7 Checking ONOS service - PASS (tick)
  • 75.8 Starting ONOS CLI sessions - PASS (tick)
  • 75.9 Checking ONOS nodes - PASS (tick)
  • 75.10 Checking ONOS applications - PASS (tick)
  • 75.11 Set logging levels - PASS (tick)
  • 75.12 Set ONOS configurations - PASS (tick)
  • 75.13 Starting Mininet Topology - PASS (tick)
  • 75.14 Check whether the flow count is >= 28 - PASS (tick)FAIL (error)
    • Flow count looks wrong; found 18, expecting at least 28
  • 75.15 Check whether all flow status are ADDED - PASS (tick)
  • 75.16 Check whether the flow count of device of:0000000000000001 >= than 28 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 18
  • 75.17 Check number of topology elements - PASS (tick)
  • 75.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE75 - PASS (tick)
  • 75.19 Stopping Mininet - PASS (tick)
  • 75.20 Copying karaf logs - PASS (tick)

...

  • 76.1 Apply cell to environment - PASS (tick)
  • 76.2 Uninstalling Atomix - PASS (tick)
  • 76.3 Uninstalling ONOS package - PASS (tick)
  • 76.4 Installing Atomix - PASS (tick)
  • 76.5 Installing ONOS package - PASS (tick)
  • 76.6 Set up ONOS secure SSH - PASS (tick)
  • 76.7 Checking ONOS service - PASS (tick)
  • 76.8 Starting ONOS CLI sessions - PASS (tick)
  • 76.9 Checking ONOS nodes - PASS (tick)
  • 76.10 Checking ONOS applications - PASS (tick)
  • 76.11 Set logging levels - PASS (tick)
  • 76.12 Set ONOS configurations - PASS (tick)
  • 76.13 Starting Mininet Topology - PASS (tick)
  • 76.14 Check whether the flow count is >= 74 - PASS (tick)
  • 76.15 Check whether all flow status are ADDED - PASS (tick)
  • 76.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS (tick)
  • 76.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS (tick)
  • 76.18 Check number of topology elements - PASS (tick)
  • 76.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE76 - PASS (tick)
  • 76.20 Stopping Mininet - PASS (tick)
  • 76.21 Copying karaf logs - PASS (tick)

Case 77: Bridging test between untagged and tagged hosts with different vlan id, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -

...

PASS

  • 77.1 Apply cell to environment - PASS (tick)
  • 77.2 Uninstalling Atomix - PASS (tick)
  • 77.3 Uninstalling ONOS package - PASS (tick)
  • 77.4 Installing Atomix - PASS (tick)
  • 77.5 Installing ONOS package - PASS (tick)
  • 77.6 Set up ONOS secure SSH - PASS (tick)
  • 77.7 Checking ONOS service - PASS (tick)
  • 77.8 Starting ONOS CLI sessions - PASS (tick)
  • 77.9 Checking ONOS nodes - PASS (tick)
  • 77.10 Checking ONOS applications - PASS (tick)
  • 77.11 Set logging levels - PASS (tick)
  • 77.12 Set ONOS configurations - PASS (tick)
  • 77.13 Starting Mininet Topology - PASS (tick)
  • 77.14 Check whether the flow count is >= 74 - FAIL (error)
  • Flow count looks wrong; found 72, expecting at least 74
  • PASS (tick)
  • 77.15 Check whether all flow status are ADDED - PASS (tick)
  • 77.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL (error)
  • Flow count looks wrong: 18
  • PASS (tick)
  • 77.17 Check whether the flow count of device of:0000000000000002 >= than 37 - FAIL (error)
  • Flow count looks wrong: 18
  • PASS (tick)
  • 77.18 Check number of topology elements - PASS (tick)
  • 77.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE77 - PASS (tick)
  • 77.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE77 - PASS (tick)
  • 77.21 Stopping Mininet - PASS (tick)
  • 77.22 Copying karaf logs - PASS (tick)

...