Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-2.2/1100/

...

  • 23.1 Apply cell to environment - PASS (tick)
  • 23.2 Uninstalling Atomix - PASS (tick)
  • 23.3 Uninstalling ONOS package - PASS (tick)
  • 23.4 Installing Atomix - PASS (tick)
  • 23.5 Installing ONOS package - PASS (tick)
  • 23.6 Set up ONOS secure SSH - PASS (tick)
  • 23.7 Checking ONOS service - PASS (tick)
  • 23.8 Starting ONOS CLI sessions - PASS (tick)
  • 23.9 Checking ONOS nodes - PASS (tick)
  • 23.10 Checking ONOS applications - PASS (tick)
  • 23.11 Starting Mininet Topology - PASS (tick)
  • 23.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.13 Check whether all flow status are ADDED - PASS (tick)
  • 23.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 23.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - FAIL (error)
    • IP connectivity failed
  • 23.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 23.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 23.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.19 Check whether all flow status are ADDED - PASS (tick)
  • 23.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS (tick)
  • 23.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 23.22 Stopping Mininet - PASS (tick)
  • 23.23 Copying karaf logs - PASS (tick)

Case 33: Changing port configuration from untagged 10 to untagged 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 33.1 Apply cell to environment - PASS (tick)
  • 33.2 Uninstalling Atomix - PASS (tick)
  • 33.3 Uninstalling ONOS package - PASS (tick)
  • 33.4 Installing Atomix - PASS (tick)
  • 33.5 Installing ONOS package - PASS (tick)
  • 33.6 Set up ONOS secure SSH - PASS (tick)
  • 33.7 Checking ONOS service - PASS (tick)
  • 33.8 Starting ONOS CLI sessions - PASS (tick)
  • 33.9 Checking ONOS nodes - PASS (tick)
  • 33.10 Checking ONOS applications - PASS (tick)
  • 33.11 Starting Mininet Topology - PASS (tick)
  • 33.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 33.13 Check whether all flow status are ADDED - PASS (tick)
  • 33.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - PASS (tick)
  • 33.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 33.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 33.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 33.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 33.19 Check whether all flow status are ADDED - PASS (tick)
  • 33.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - PASS (tick)
  • 33.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS (tick)
  • 33.22 Stopping Mininet - PASS (tick)
  • 33.23 Copying karaf logs - PASS (tick)

...

  • 53.1 Apply cell to environment - PASS (tick)
  • 53.2 Uninstalling Atomix - PASS (tick)
  • 53.3 Uninstalling ONOS package - PASS (tick)
  • 53.4 Installing Atomix - PASS (tick)
  • 53.5 Installing ONOS package - PASS (tick)
  • 53.6 Set up ONOS secure SSH - PASS (tick)
  • 53.7 Checking ONOS service - PASS (tick)
  • 53.8 Starting ONOS CLI sessions - PASS (tick)
  • 53.9 Checking ONOS nodes - PASS (tick)
  • 53.10 Checking ONOS applications - PASS (tick)
  • 53.11 Starting Mininet Topology - PASS (tick)
  • 53.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 53.13 Check whether all flow status are ADDED - PASS (tick)
  • 53.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_Before - PASS (tick)
  • 53.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_Before - PASS (tick)
  • 53.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 53.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 53.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 53.19 Check whether all flow status are ADDED - PASS (tick)
  • 53.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_After - PASS (tick)
  • 53.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_After - PASS (tick)
  • 53.22 Stopping Mininet - PASS (tick)
  • 53.23 Copying karaf logs - PASS (tick)

Case 63: Changing port configuration from untagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 63.1 Apply cell to environment - PASS (tick)
  • 63.2 Uninstalling Atomix - PASS (tick)
  • 63.3 Uninstalling ONOS package - PASS (tick)
  • 63.4 Installing Atomix - PASS (tick)
  • 63.5 Installing ONOS package - PASS (tick)
  • 63.6 Set up ONOS secure SSH - PASS (tick)
  • 63.7 Checking ONOS service - PASS (tick)
  • 63.8 Starting ONOS CLI sessions - PASS (tick)
  • 63.9 Checking ONOS nodes - PASS (tick)
  • 63.10 Checking ONOS applications - PASS (tick)
  • 63.11 Starting Mininet Topology - PASS (tick)
  • 63.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 63.13 Check whether all flow status are ADDED - PASS (tick)
  • 63.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS (tick)
  • 63.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 63.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 63.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 63.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 63.19 Check whether all flow status are ADDED - PASS (tick)
  • 63.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS (tick)
  • 63.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS (tick)
  • 63.22 Stopping Mininet - PASS (tick)
  • 63.23 Copying karaf logs - PASS (tick)

Case 73: Changing port configuration from tagged 10 to untagged 10

...

  • 73.1 Apply cell to environment - PASS (tick)
  • 73.2 Uninstalling Atomix - PASS (tick)
  • 73.3 Uninstalling ONOS package - PASS (tick)
  • 73.4 Installing Atomix - PASS (tick)
  • 73.5 Installing ONOS package - PASS (tick)
  • 73.6 Set up ONOS secure SSH - PASS (tick)
  • 73.7 Checking ONOS service - PASS (tick)
  • 73.8 Starting ONOS CLI sessions - PASS (tick)
  • 73.9 Checking ONOS nodes - PASS (tick)
  • 73.10 Checking ONOS applications - PASS (tick)
  • 73.11 Starting Mininet Topology - PASS (tick)
  • 73.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 73.13 Check whether all flow status are ADDED - PASS (tick)
  • 73.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE73_Before - PASS (tick)
  • 73.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE73_Before - PASS (tick)
  • 73.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 73.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 73.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 73.19 Check whether all flow status are ADDED - PASS (tick)
  • 73.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE73_After - PASS (tick)
  • 73.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE73_After - PASS (tick)
  • 73.22 Stopping Mininet - PASS (tick)
  • 73.23 Copying karaf logs - PASS (tick)

Case 83: Changing port configuration from tagged 20 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

  • 83.1 Apply cell to environment - PASS (tick)
  • 83.2 Uninstalling Atomix - PASS (tick)
  • 83.3 Uninstalling ONOS package - PASS (tick)
  • 83.4 Installing Atomix - PASS (tick)
  • 83.5 Installing ONOS package - PASS (tick)
  • 83.6 Set up ONOS secure SSH - PASS (tick)
  • 83.7 Checking ONOS service - PASS (tick)
  • 83.8 Starting ONOS CLI sessions - PASS (tick)
  • 83.9 Checking ONOS nodes - PASS (tick)
  • 83.10 Checking ONOS applications - PASS (tick)
  • 83.11 Starting Mininet Topology - PASS (tick)
  • 83.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 83.13 Check whether all flow status are ADDED - PASS (tick)
  • 83.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_Before - FAIL (error)
    • IP connectivity failed
  • 83.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_Before - PASS (tick)
  • 83.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 83.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 83.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 83.19 Check whether all flow status are ADDED - PASS (tick)
  • 83.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_After - FAIL (error)
    • IP connectivity failed
  • 83.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_After - FAIL (error)
    • IP connectivity failed
  • 83.22 Stopping Mininet - PASS (tick)
  • 83.23 Copying karaf logs - PASS (tick)

Case 93: Changing port configuration from tagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

  • 93.1 Apply cell to environment - PASS (tick)
  • 93.2 Uninstalling Atomix - PASS (tick)
  • 93.3 Uninstalling ONOS package - PASS (tick)
  • 93.4 Installing Atomix - PASS (tick)
  • 93.5 Installing ONOS package - PASS (tick)
  • 93.6 Set up ONOS secure SSH - PASS (tick)
  • 93.7 Checking ONOS service - PASS (tick)
  • 93.8 Starting ONOS CLI sessions - PASS (tick)
  • 93.9 Checking ONOS nodes - PASS (tick)
  • 93.10 Checking ONOS applications - PASS (tick)
  • 93.11 Starting Mininet Topology - PASS (tick)
  • 93.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 93.13 Check whether all flow status are ADDED - PASS (tick)
  • 93.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_Before - PASS (tick)
  • 93.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_Before - PASS (tick)
  • 93.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 93.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 93.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 93.19 Check whether all flow status are ADDED - PASS (tick)
  • 93.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_After - PASS (tick)
  • 93.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_After - PASS (tick)
  • 93.22 Stopping Mininet - PASS (tick)
  • 93.23 Copying karaf logs - PASS (tick)

Case 103: Changing port configuration from tagged 10 and native 20 to untagged 20, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

  • 103.1 Apply cell to environment - PASS (tick)
  • 103.2 Uninstalling Atomix - PASS (tick)
  • 103.3 Uninstalling ONOS package - PASS (tick)
  • 103.4 Installing Atomix - PASS (tick)
  • 103.5 Installing ONOS package - PASS (tick)
  • 103.6 Set up ONOS secure SSH - PASS (tick)
  • 103.7 Checking ONOS service - PASS (tick)
  • 103.8 Starting ONOS CLI sessions - PASS (tick)
  • 103.9 Checking ONOS nodes - PASS (tick)
  • 103.10 Checking ONOS applications - PASS (tick)
  • 103.11 Starting Mininet Topology - PASS (tick)
  • 103.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 103.13 Check whether all flow status are ADDED - PASS (tick)
  • 103.14 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_Before - FAIL (error)
    • IP connectivity failed
  • 103.15 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 103.16 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 103.17 Check whether the flow count is bigger than 104 - PASS (tick)
  • 103.18 Check whether all flow status are ADDED - PASS (tick)
  • 103.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_After - FAIL (error)
    • IP connectivity failed
  • 103.20 Stopping Mininet - PASS (tick)
  • 103.21 Copying karaf logs - PASS (tick)

Case 113: Changing port configuration from tagged 20 and native 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

  • 113.1 Apply cell to environment - PASS (tick)
  • 113.2 Uninstalling Atomix - PASS (tick)
  • 113.3 Uninstalling ONOS package - PASS (tick)
  • 113.4 Installing Atomix - PASS (tick)
  • 113.5 Installing ONOS package - PASS (tick)
  • 113.6 Set up ONOS secure SSH - PASS (tick)
  • 113.7 Checking ONOS service - PASS (tick)
  • 113.8 Starting ONOS CLI sessions - PASS (tick)
  • 113.9 Checking ONOS nodes - PASS (tick)
  • 113.10 Checking ONOS applications - PASS (tick)
  • 113.11 Starting Mininet Topology - PASS (tick)
  • 113.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 113.13 Check whether all flow status are ADDED - PASS (tick)
  • 113.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - PASS (tick)
  • 113.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - PASS (tick)
  • 113.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 113.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 113.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 113.19 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 113.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - PASS (tick)
  • 113.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS (tick)
  • 113.22 Stopping Mininet - PASS (tick)
  • 113.23 Copying karaf logs - PASS (tick)

Case 123: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

  • 123.1 Apply cell to environment - PASS (tick)
  • 123.2 Uninstalling Atomix - PASS (tick)
  • 123.3 Uninstalling ONOS package - PASS (tick)
  • 123.4 Installing Atomix - PASS (tick)
  • 123.5 Installing ONOS package - PASS (tick)
  • 123.6 Set up ONOS secure SSH - PASS (tick)
  • 123.7 Checking ONOS service - PASS (tick)
  • 123.8 Starting ONOS CLI sessions - PASS (tick)
  • 123.9 Checking ONOS nodes - PASS (tick)
  • 123.10 Checking ONOS applications - PASS (tick)
  • 123.11 Starting Mininet Topology - PASS (tick)
  • 123.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 123.13 Check whether all flow status are ADDED - PASS (tick)
  • 123.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_Before - PASS (tick)
  • 123.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_Before - PASS (tick)
  • 123.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 123.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 123.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 123.19 Check whether all flow status are ADDED - PASS (tick)
  • 123.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_After - PASS (tick)
  • 123.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_After - PASS (tick)
  • 123.22 Stopping Mininet - PASS (tick)
  • 123.23 Copying karaf logs - PASS (tick)

Case 133: Changing port configuration from tagged 20 and native 10 to tagged 120 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

  • 133.1 Apply cell to environment - PASS (tick)
  • 133.2 Uninstalling Atomix - PASS (tick)
  • 133.3 Uninstalling ONOS package - PASS (tick)
  • 133.4 Installing Atomix - PASS (tick)
  • 133.5 Installing ONOS package - PASS (tick)
  • 133.6 Set up ONOS secure SSH - PASS (tick)
  • 133.7 Checking ONOS service - PASS (tick)
  • 133.8 Starting ONOS CLI sessions - PASS (tick)
  • 133.9 Checking ONOS nodes - PASS (tick)
  • 133.10 Checking ONOS applications - PASS (tick)
  • 133.11 Starting Mininet Topology - PASS (tick)
  • 133.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 133.13 Check whether all flow status are ADDED - PASS (tick)
  • 133.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE133_Before - PASS (tick)
  • 133.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE133_Before - PASS (tick)
  • 133.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 133.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 133.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 133.19 Check whether all flow status are ADDED - PASS (tick)
  • 133.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE133_After - PASS (tick)
  • 133.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE133_After - PASS (tick)
  • 133.22 Stopping Mininet - PASS (tick)
  • 133.23 Copying karaf logs - PASS (tick)

Case 143: Changing port configuration from untagged 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

  • 143.1 Apply cell to environment - PASS (tick)
  • 143.2 Uninstalling Atomix - PASS (tick)
  • 143.3 Uninstalling ONOS package - PASS (tick)
  • 143.4 Installing Atomix - PASS (tick)
  • 143.5 Installing ONOS package - PASS (tick)
  • 143.6 Set up ONOS secure SSH - PASS (tick)
  • 143.7 Checking ONOS service - PASS (tick)
  • 143.8 Starting ONOS CLI sessions - PASS (tick)
  • 143.9 Checking ONOS nodes - PASS (tick)
  • 143.10 Checking ONOS applications - PASS (tick)
  • 143.11 Starting Mininet Topology - PASS (tick)
  • 143.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 143.13 Check whether all flow status are ADDED - PASS (tick)
  • 143.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE143_Before - PASS (tick)
  • 143.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE143_Before - PASS (tick)
  • 143.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 143.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 143.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 143.19 Check whether all flow status are ADDED - PASS (tick)
  • 143.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE143_After - PASS (tick)
  • 143.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE143_After - PASS (tick)
  • 143.22 Stopping Mininet - PASS (tick)
  • 143.23 Copying karaf logs - PASS (tick)

...

, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL