Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRSwitchFailure_master_20-builds_graph.jpg", alt="SRSwitchFailure", style="width:525px;height:350px;border:0"> |
commit b53d626fb03195129c0ec0802e1f953f85dcbef8 (HEAD -] master commit 76057cde820aa703b2bcf7caf820ccbe9b01b941 (HEAD, origin/master, origin/HEAD, master)
Author: Frank Wang pierventre [wangpeihuixyz@126pier@opennetworking.comorg]
AuthorDate: Sat Jul 15 10:22:03 2017 +0800Wed Sep 22 11:24:38 2021 +0200
Commit: Frank Wang [wangpeihuixyz@126.comPier Luigi Ventre [pier@opennetworking.org]
CommitDate: Wed Jul 19 10:03:56 2017 +0800
fix equal tests for PiCriteria class
...
Thu Sep 23 07:38:36 2021 +0000
[SDFAB-612] Cluster not ready when using recent tost master images
--
(cherry picked from commit ec0e942320ef27932b4173172055151015261d7c)
Case 1: Switch Failure test with 2x2 leaf-spine topology and 1 Onos - PASS
- 1.1 Constructing test variables - PASS
- 1.2 Apply cell to environment - PASS
- 1.3 Uninstalling Atomix - PASS
- 1.4 Uninstalling ONOS package - PASS
- 1.5 Creating ONOS package - PASS
- 1.6 Installing Atomix - PASS
- 1.7 Installing ONOS package - PASS
- 1.8 Set up ONOS secure SSH - PASS
- 1.9 Checking ONOS service - PASS
- 1.10 Starting ONOS CLI sessions - PASS
- 1.11 Checking ONOS nodes - PASS
- 1.12 Checking ONOS applications - PASS
- 1.13 Set logging levels - PASS
- 1.14 Set ONOS configurations - PASS
- 1.15 Starting Mininet Topology - PASS
- 1.16 Check whether the flow count is >= 116 - PASS
- 1.17 Check whether all flow status are ADDED - PASS
- 1.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - PASS
- 1.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS
- 1.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS
- 1.21 Kill ['spine101'] - PASS
- 1.22 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - PASS
- 1.23 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - PASS
- 1.24 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - PASS
- 1.25 Recovering ['spine101'] - PASS
- 1.26 Check whether the flow count is >= 116 - PASS
- 1.27 Check whether all flow status are ADDED - PASS
- 1.28 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Recovery - PASS
- 1.29 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Recovery - PASS
- 1.30 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Recovery - PASS
- 1.31 Stopping Mininet - PASS
- 1.32 Copying karaf logs - PASS