Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-2.2/1149/

...

commit 5e8f07e1d2597767353f44804d9ea0058c20341d (HEAD -] onos-2.2, origin/onos-2.2)
Author: ONOS Jenkins User [jenkins@onlab.us]
AuthorDate: Wed Jan 29 02:25:41 2020 +0000
Commit: ONOS Jenkins User [jenkins@onlab.us]
CommitDate: Wed Jan 29 02:25:41 2020 +0000

Starting snapshot 2.2.1-SNAPSHOT

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances -

...

FAIL

  • 5.1 Constructing test variables - PASS (tick)
  • 5.2 Apply cell to environment - PASS (tick)
  • 5.3 Uninstalling Atomix - PASS (tick)
  • 5.4 Uninstalling ONOS package - PASS (tick)
  • 5.5 Creating ONOS package - PASS (tick)
  • 5.6 Installing Atomix - PASS (tick)
  • 5.7 Installing ONOS package - PASS (tick)
  • 5.8 Set up ONOS secure SSH - PASS (tick)
  • 5.9 Checking ONOS service - PASS (tick)
  • 5.10 Starting ONOS CLI sessions - PASS (tick)
  • 5.11 Checking ONOS nodes - PASS (tick)
  • 5.12 Checking ONOS applications - PASS (tick)
  • 5.13 Starting Mininet Topology - PASS (tick)
  • 5.14 Check whether the flow count is bigger than 28 - PASS (tick)
  • 5.15 Check whether all flow status are ADDED - PASS (tick)
  • 5.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 5.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 5.18 Stopping Mininet - PASS (tick)
  • 5.19 Copying karaf logs - PASS (tick)

...

  • 16.1 Apply cell to environment - PASS (tick)
  • 16.2 Uninstalling Atomix - PASS (tick)
  • 16.3 Uninstalling ONOS package - PASS (tick)
  • 16.4 Installing Atomix - PASS (tick)
  • 16.5 Installing ONOS package - PASS (tick)
  • 16.6 Set up ONOS secure SSH - PASS (tick)
  • 16.7 Checking ONOS service - PASS (tick)
  • 16.8 Starting ONOS CLI sessions - PASS (tick)
  • 16.9 Checking ONOS nodes - PASS (tick)
  • 16.10 Checking ONOS applications - PASS (tick)
  • 16.11 Starting Mininet Topology - PASS (tick)
  • 16.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 16.13 Check whether all flow status are ADDED - PASS (tick)
  • 16.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 16.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 16.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE16 - PASS (tick)
  • 16.17 Stopping Mininet - PASS (tick)
  • 16.18 Copying karaf logs - PASS (tick)

Case 17: Bridging test between two tagged hosts, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 17.1 Apply cell to environment - PASS (tick)
  • 17.2 Uninstalling Atomix - PASS (tick)
  • 17.3 Uninstalling ONOS package - PASS (tick)
  • 17.4 Installing Atomix - PASS (tick)
  • 17.5 Installing ONOS package - PASS (tick)
  • 17.6 Set up ONOS secure SSH - PASS (tick)
  • 17.7 Checking ONOS service - PASS (tick)
  • 17.8 Starting ONOS CLI sessions - PASS (tick)
  • 17.9 Checking ONOS nodes - PASS (tick)
  • 17.10 Checking ONOS applications - PASS (tick)
  • 17.11 Starting Mininet Topology - PASS (tick)
  • 17.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 17.13 Check whether all flow status are ADDED - PASS (tick)
  • 17.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 17.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 17.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 17.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - PASS (tick)
  • 17.18 Stopping Mininet - PASS (tick)
  • 17.19 Copying karaf logs - PASS (tick)

...

  • 28.1 Apply cell to environment - PASS (tick)
  • 28.2 Uninstalling Atomix - PASS (tick)
  • 28.3 Uninstalling ONOS package - PASS (tick)
  • 28.4 Installing Atomix - PASS (tick)
  • 28.5 Installing ONOS package - PASS (tick)
  • 28.6 Set up ONOS secure SSH - PASS (tick)
  • 28.7 Checking ONOS service - PASS (tick)
  • 28.8 Starting ONOS CLI sessions - PASS (tick)
  • 28.9 Checking ONOS nodes - PASS (tick)
  • 28.10 Checking ONOS applications - PASS (tick)
  • 28.11 Starting Mininet Topology - PASS (tick)
  • 28.12 Check whether the flow count is bigger than 212 - PASS (tick)
  • 28.13 Check whether all flow status are ADDED - PASS (tick)
  • 28.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 28.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 28.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 28.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 28.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE28 - PASS (tick)
  • 28.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE28 - PASS (tick)
  • 28.20 Stopping Mininet - PASS (tick)
  • 28.21 Copying karaf logs - PASS (tick)

Case 35: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with single ToR and 3 ONOS instances -

...

FAIL

  • 35.1 Apply cell to environment - PASS (tick)
  • 35.2 Uninstalling Atomix - PASS (tick)
  • 35.3 Uninstalling ONOS package - PASS (tick)
  • 35.4 Installing Atomix - PASS (tick)
  • 35.5 Installing ONOS package - PASS (tick)
  • 35.6 Set up ONOS secure SSH - PASS (tick)
  • 35.7 Checking ONOS service - PASS (tick)
  • 35.8 Starting ONOS CLI sessions - PASS (tick)
  • 35.9 Checking ONOS nodes - PASS (tick)
  • 35.10 Checking ONOS applications - PASS (tick)
  • 35.11 Starting Mininet Topology - PASS (tick)
  • 35.12 Check whether the flow count is bigger than 28 - PASS (tick)
  • 35.13 Check whether all flow status are ADDED - PASS (tick)
  • 35.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 35.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE35 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 35.16 Stopping Mininet - PASS (tick)
  • 35.17 Copying karaf logs - PASS (tick)

...

  • 46.1 Apply cell to environment - PASS (tick)
  • 46.2 Uninstalling Atomix - PASS (tick)
  • 46.3 Uninstalling ONOS package - PASS (tick)
  • 46.4 Installing Atomix - PASS (tick)
  • 46.5 Installing ONOS package - PASS (tick)
  • 46.6 Set up ONOS secure SSH - PASS (tick)
  • 46.7 Checking ONOS service - PASS (tick)
  • 46.8 Starting ONOS CLI sessions - PASS (tick)
  • 46.9 Checking ONOS nodes - PASS (tick)
  • 46.10 Checking ONOS applications - PASS (tick)
  • 46.11 Starting Mininet Topology - PASS (tick)
  • 46.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 46.13 Check whether all flow status are ADDED - PASS (tick)
  • 46.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 46.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 46.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - PASS (tick)
  • 46.17 Stopping Mininet - PASS (tick)
  • 46.18 Copying karaf logs - PASS (tick)

Case 47: Bridging test between untagged host and tagged host, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 47.1 Apply cell to environment - PASS (tick)
  • 47.2 Uninstalling Atomix - PASS (tick)
  • 47.3 Uninstalling ONOS package - PASS (tick)
  • 47.4 Installing Atomix - PASS (tick)
  • 47.5 Installing ONOS package - PASS (tick)
  • 47.6 Set up ONOS secure SSH - PASS (tick)
  • 47.7 Checking ONOS service - PASS (tick)
  • 47.8 Starting ONOS CLI sessions - PASS (tick)
  • 47.9 Checking ONOS nodes - PASS (tick)
  • 47.10 Checking ONOS applications - PASS (tick)
  • 47.11 Starting Mininet Topology - PASS (tick)
  • 47.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 47.13 Check whether all flow status are ADDED - PASS (tick)
  • 47.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 47.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL (error)
    • Flow count looks wrong: 19
  • PASS (tick)
  • 47.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - PASS (tick)
  • 47.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 47.18 Stopping Mininet - PASS (tick)
  • 47.19 Copying karaf logs - PASS (tick)

...