Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRDynamicConf_onos-2.2_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0"> |
commit 0ee285a8fb9ff3362d11cf40fc37602cc1b1465d 528f96e3fcee90d2c2e8ad32530b89dc176753db (HEAD -] onos-2.2, origin/onos-2.2)
Author: pier Jian Li [pier@opennetworkingpyguni@gmail.orgcom]
AuthorDate: Fri Wed Apr 3 1229 23:4436:21 15 2020 +02000900
Commit: Pier Luigi Ventre [pier@opennetworking.orgJian Li [pyguni@gmail.com]
CommitDate: Fri Wed Apr 29 17 13:4329:38 2020 +0000
[ONOS-8086] Groups entries are not deleted
...
15 2020 +0000
Fix: correctly specify the VM's mac associated with the given FIP
Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL
- 13.1 Constructing test variables - PASS
- 13.2 Apply cell to environment - PASS
- 13.3 Uninstalling Atomix - PASS
- 13.4 Uninstalling ONOS package - PASS
- 13.5 Creating ONOS package - PASS
- 13.6 Installing Atomix - PASS
- 13.7 Installing ONOS package - PASS
- 13.8 Set up ONOS secure SSH - PASS
- 13.9 Checking ONOS service - PASS
- 13.10 Starting ONOS CLI sessions - PASS
- 13.11 Checking ONOS nodes - PASS
- 13.12 Checking ONOS applications - PASS
- 13.13 Starting Mininet Topology - PASS
- 13.14 Check whether the flow count is bigger than 104 - PASS
- 13.15 Check whether all flow status are ADDED - PASS
- 13.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - FAIL
- IP connectivity failed
- 13.17 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 13.18 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 13.19 Check whether the flow count is bigger than 104 - PASS
- 13.20 Check whether all flow status are ADDED - PASS
- 13.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - PASS
- 13.22 Stopping Mininet - PASS
- 13.23 Copying karaf logs - PASS
Case 23: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS
- 23.1 Apply cell to environment - PASS
- 23.2 Uninstalling Atomix - PASS
- 23.3 Uninstalling ONOS package - PASS
- 23.4 Installing Atomix - PASS
- 23.5 Installing ONOS package - PASS
- 23.6 Set up ONOS secure SSH - PASS
- 23.7 Checking ONOS service - PASS
- 23.8 Starting ONOS CLI sessions - PASS
- 23.9 Checking ONOS nodes - PASS
- 23.10 Checking ONOS applications - PASS
- 23.11 Starting Mininet Topology - PASS
- 23.12 Check whether the flow count is bigger than 106 - PASS
- 23.13 Check whether all flow status are ADDED - PASS
- 23.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS
- 23.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS
- 23.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 23.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 23.18 Check whether the flow count is bigger than 106 - PASS
- 23.19 Check whether all flow status are ADDED - PASS
- 23.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS
- 23.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS
- 23.22 Stopping Mininet - PASS
- 23.23 Copying karaf logs - PASS