Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRDynamicConf_onos-2.2_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0">

commit 70806974cd3b9ba9bb7217e1495c038f1980fc10 5908b5642a41e5755adcf7ec10f3d4f2c0ea2657 (HEAD -] onos-2.2, origin/onos-2.2)
Author: nosignal [howard_hsu@edge-core.comAndrea Campanella [andrea@opennetworking.org]
AuthorDate: Mon Apr 20 15:29:32 2020 +0800Wed May 6 16:09:10 2020 +0200
Commit: Carmelo Cascone Andrea Campanella [carmelo@opennetworkingandrea@opennetworking.org]
CommitDate: Tue Fri May 5 0215 17:0300:41 00 2020 +0000
Fix deps link of perfmark
--
(cherry picked from commit bf220fd844497b57b94804fde347ca6fddb3dd7a)
[VOL-3016] OLTPipeline removes empty next group if the last group was removed because of empty buckets

Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

...

  • 73.1 Apply cell to environment - PASS (tick)
  • 73.2 Uninstalling Atomix - PASS (tick)
  • 73.3 Uninstalling ONOS package - PASS (tick)
  • 73.4 Installing Atomix - PASS (tick)
  • 73.5 Installing ONOS package - PASS (tick)
  • 73.6 Set up ONOS secure SSH - PASS (tick)
  • 73.7 Checking ONOS service - PASS (tick)
  • 73.8 Starting ONOS CLI sessions - PASS (tick)
  • 73.9 Checking ONOS nodes - PASS (tick)
  • 73.10 Checking ONOS applications - PASS (tick)
  • 73.11 Starting Mininet Topology - PASS (tick)
  • 73.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 73.13 Check whether all flow status are ADDED - PASS (tick)
  • 73.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE73_Before - PASS (tick)
  • 73.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE73_Before - PASS (tick)
  • 73.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 73.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 73.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 73.19 Check whether all flow status are ADDED - PASS (tick)
  • 73.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE73_After - PASS (tick)
  • 73.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE73_After - PASS (tick)
  • 73.22 Stopping Mininet - PASS (tick)
  • 73.23 Copying karaf logs - PASS (tick)

Case 83: Changing port configuration from tagged 20 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 83.1 Apply cell to environment - PASS (tick)
  • 83.2 Uninstalling Atomix - PASS (tick)
  • 83.3 Uninstalling ONOS package - PASS (tick)
  • 83.4 Installing Atomix - PASS (tick)
  • 83.5 Installing ONOS package - PASS (tick)
  • 83.6 Set up ONOS secure SSH - PASS (tick)
  • 83.7 Checking ONOS service - PASS (tick)
  • 83.8 Starting ONOS CLI sessions - PASS (tick)
  • 83.9 Checking ONOS nodes - PASS (tick)
  • 83.10 Checking ONOS applications - PASS (tick)
  • 83.11 Starting Mininet Topology - PASS (tick)
  • 83.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 83.13 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • PASS (tick)
  • 83.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_Before - PASS (tick)
  • 83.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_Before - PASS (tick)
  • 83.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 83.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL (error)
  • Flow count looks wrong: 19
  • PASS (tick)
  • 83.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 83.19 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 83.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_After - PASS (tick)
  • 83.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_After - PASS (tick)
  • 83.22 Stopping Mininet - PASS (tick)
  • 83.23 Copying karaf logs - PASS (tick)

Case 93: Changing port configuration from tagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 93.1 Apply cell to environment - PASS (tick)
  • 93.2 Uninstalling Atomix - PASS (tick)
  • 93.3 Uninstalling ONOS package - PASS (tick)
  • 93.4 Installing Atomix - PASS (tick)
  • 93.5 Installing ONOS package - PASS (tick)
  • 93.6 Set up ONOS secure SSH - PASS (tick)
  • 93.7 Checking ONOS service - PASS (tick)
  • 93.8 Starting ONOS CLI sessions - PASS (tick)
  • 93.9 Checking ONOS nodes - PASS (tick)
  • 93.10 Checking ONOS applications - PASS (tick)
  • 93.11 Starting Mininet Topology - PASS (tick)
  • 93.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 93.13 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 93.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 93.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 93.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 20
  • 93.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 93.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 93.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 93.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 93.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 93.22 Stopping Mininet - PASS (tick)
  • 93.23 Copying karaf logs - PASS (tick)

...

  • 123.1 Apply cell to environment - PASS (tick)
  • 123.2 Uninstalling Atomix - PASS (tick)
  • 123.3 Uninstalling ONOS package - PASS (tick)
  • 123.4 Installing Atomix - PASS (tick)
  • 123.5 Installing ONOS package - PASS (tick)
  • 123.6 Set up ONOS secure SSH - PASS (tick)
  • 123.7 Checking ONOS service - PASS (tick)
  • 123.8 Starting ONOS CLI sessions - PASS (tick)
  • 123.9 Checking ONOS nodes - PASS (tick)
  • 123.10 Checking ONOS applications - PASS (tick)
  • 123.11 Starting Mininet Topology - PASS (tick)
  • 123.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 123.13 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 123.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 123.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 123.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 23
  • 123.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 123.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 123.19 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 123.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 123.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 123.22 Stopping Mininet - PASS (tick)
  • 123.23 Copying karaf logs - PASS (tick)

...

  • 183.1 Apply cell to environment - PASS (tick)
  • 183.2 Uninstalling Atomix - PASS (tick)
  • 183.3 Uninstalling ONOS package - PASS (tick)
  • 183.4 Installing Atomix - PASS (tick)
  • 183.5 Installing ONOS package - PASS (tick)
  • 183.6 Set up ONOS secure SSH - PASS (tick)
  • 183.7 Checking ONOS service - PASS (tick)
  • 183.8 Starting ONOS CLI sessions - PASS (tick)
  • 183.9 Checking ONOS nodes - PASS (tick)
  • 183.10 Checking ONOS applications - PASS (tick)
  • 183.11 Starting Mininet Topology - PASS (tick)
  • 183.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 183.13 Check whether all flow status are ADDED - PASS (tick)
  • 183.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_Before - PASS (tick)
  • 183.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_Before - PASS (tick)
  • 183.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 183.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 183.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 183.19 Check whether all flow status are ADDED - PASS (tick)
  • 183.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_After - PASS (tick)
  • 183.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_After - PASS (tick)
  • 183.22 Stopping Mininet - PASS (tick)
  • 183.23 Copying karaf logs - PASS (tick)

Case 193: Changing port configuration from tagged 20 and native 10 to untagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 193.1 Apply cell to environment - PASS (tick)
  • 193.2 Uninstalling Atomix - PASS (tick)
  • 193.3 Uninstalling ONOS package - PASS (tick)
  • 193.4 Installing Atomix - PASS (tick)
  • 193.5 Installing ONOS package - PASS (tick)
  • 193.6 Set up ONOS secure SSH - PASS (tick)
  • 193.7 Checking ONOS service - PASS (tick)
  • 193.8 Starting ONOS CLI sessions - PASS (tick)
  • 193.9 Checking ONOS nodes - PASS (tick)
  • 193.10 Checking ONOS applications - PASS (tick)
  • 193.11 Starting Mininet Topology - PASS (tick)
  • 193.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 193.13 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • PASS (tick)
  • 193.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE193_Before - PASS (tick)
  • 193.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE193_Before - PASS (tick)
  • 193.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 193.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL (error)
    • Flow count looks wrong: 19
  • PASS (tick)
  • 193.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 193.19 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • PASS (tick)
  • 193.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE193_After - PASS (tick)
  • 193.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE193_After - PASS (tick)
  • 193.22 Stopping Mininet - PASS (tick)
  • 193.23 Copying karaf logs - PASS (tick)

...

  • 233.1 Apply cell to environment - PASS (tick)
  • 233.2 Uninstalling Atomix - PASS (tick)
  • 233.3 Uninstalling ONOS package - PASS (tick)
  • 233.4 Installing Atomix - PASS (tick)
  • 233.5 Installing ONOS package - PASS (tick)
  • 233.6 Set up ONOS secure SSH - PASS (tick)
  • 233.7 Checking ONOS service - PASS (tick)
  • 233.8 Starting ONOS CLI sessions - PASS (tick)
  • 233.9 Checking ONOS nodes - PASS (tick)
  • 233.10 Checking ONOS applications - PASS (tick)
  • 233.11 Starting Mininet Topology - PASS (tick)
  • 233.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 233.13 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 233.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_Before - PASS (tick)
  • 233.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_Before - PASS (tick)
  • 233.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.18 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.19 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_1 - PASS (tick)
  • 233.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_1 - PASS (tick)
  • 233.22 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.23 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.24 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_2 - PASS (tick)
  • 233.25 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_2 - PASS (tick)
  • 233.26 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.27 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.28 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_3 - PASS (tick)
  • 233.29 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_3 - PASS (tick)
  • 233.30 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.31 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.32 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_4 - PASS (tick)
  • 233.33 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_4 - FAIL (error)
    • IP connectivity failed
  • 233.34 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.35 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.36 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_5 - PASS (tick)
  • 233.37 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_5 - PASS (tick)
  • 233.38 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.39 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.40 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_6 - PASS (tick)
  • 233.41 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_6 - PASS (tick)
  • 233.42 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.43 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.44 Check whether the flow count is bigger than 104 - PASS (tick)
  • 233.45 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 233.46 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_After - PASS (tick)
  • 233.47 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_After - PASS (tick)
  • 233.48 Stopping Mininet - PASS (tick)
  • 233.49 Copying karaf logs - PASS (tick)

...