Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRSwitchFailure_master_20-builds_graph.jpg", alt="SRSwitchFailure", style="width:525px;height:350px;border:0"> |
commit 59a9605ced9d4e2f2e4ffa28be4b34add89978a4 2325050b8bf9bf8b0819c2ed546c5fc71fa13c0e (HEAD -] master, origin/master, origin/HEAD)
Author: Jian Li Andrea Campanella [pyguni@gmailandrea@opennetworking.comorg]
AuthorDate: Thu Apr 30 12:00:13 2020 +0900Wed May 13 15:36:57 2020 +0200
Commit: Jian Li Andrea Campanella [pyguni@gmailandrea@opennetworking.comorg]
CommitDate: Thu Apr 30 04:21:07 Wed May 13 16:16:45 2020 +0000
Fix: correctly broadcast ARP MAC and IP reply for fake gateway
[ONOS-8093] Purge Meter API
--
(cherry picked from commit aec1b136f6f908b67a19c5e58cd8cbbeaf37769e4e4084cd6ded060616a5afa7d3af427715cfc2d0)
Case 1: Switch Failure test with 2x2 Leaf-spine and 1 Onos - FAIL
...
- 4.1 Apply cell to environment - PASS
- 4.2 Uninstalling Atomix - PASS
- 4.3 Uninstalling ONOS package - PASS
- 4.4 Creating ONOS package - PASS
- 4.5 Installing Atomix - PASS
- 4.6 Installing ONOS package - PASS
- 4.7 Set up ONOS secure SSH - PASS
- 4.8 Checking ONOS service - PASS
- 4.9 Starting ONOS CLI sessions - PASS
- 4.10 Checking ONOS nodes - PASS
- 4.11 Checking ONOS applications - PASS
- 4.12 Starting Mininet Topology - PASS
- 4.13 Check whether the flow count is bigger than 116 - PASS
- 4.14 Check whether all flow status are ADDED - PASS
- 4.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4 - FAIL
- IP connectivity failed
- 4.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4 - FAIL
- IP connectivity failed
- 4.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4 - FAIL
- IP connectivity failed
- 4.18 Kill ['spine101'] - FAIL
- Failed to kill switch?
- 4.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4_Failure - FAIL
- IP connectivity failed
- 4.20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_Failure - FAIL
- IP connectivity failed
- 4.21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_Failure - FAIL
- IP connectivity failed
- 4.22 Recovering ['spine101'] - FAIL
- Failed to recover switch?
- 4.23 Check whether the flow count is bigger than 116 - PASS
- 4.24 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 4.25 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4_Recovery - FAIL
- IP connectivity failed
- 4.26 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_Recovery - FAIL
- IP connectivity failed
- 4.27 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_Recovery - FAIL
- IP connectivity failed
- 4.28 Stopping Mininet - PASS
- 4.29 Copying karaf logs - PASS
...