Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRDynamicConf_onos-2.2_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0">

commit 4ac9f9b8a4ef5eaa4720c1b43862c243ff722b56 87b3f864da3e0486a171a9c362754cebdf391d98 (HEAD -] onos-2.2, origin/onos-2.2)
Author: Jian Li Sean Condon [pyguni@gmailsean@opennetworking.comorg]
AuthorDate: Mon Thu May 18 1721 16:4814:48 54 2020 +09000100
Commit: Jian Li Sean Condon [pyguni@gmailsean@opennetworking.comorg]
CommitDate: Mon Fri May 18 1822 15:4154:18 50 2020 +0900
Fix: only reply ARP request from external router0100

[ONOS-8096] In GUI2 device panel space before colon creates unnecessary wrap

Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 13.1 Constructing test variables - PASS (tick)
  • 13.2 Apply cell to environment - PASS (tick)
  • 13.3 Uninstalling Atomix - PASS (tick)
  • 13.4 Uninstalling ONOS package - PASS (tick)
  • 13.5 Creating ONOS package - PASS (tick)
  • 13.6 Installing Atomix - PASS (tick)
  • 13.7 Installing ONOS package - PASS (tick)
  • 13.8 Set up ONOS secure SSH - PASS (tick)
  • 13.9 Checking ONOS service - PASS (tick)
  • 13.10 Starting ONOS CLI sessions - PASS (tick)
  • 13.11 Checking ONOS nodes - PASS (tick)
  • 13.12 Checking ONOS applications - PASS (tick)
  • 13.13 Starting Mininet Topology - PASS (tick)
  • 13.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.15 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 13.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 13.17 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 24
  • 13.18 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 13.19 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.20 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 13.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 13.22 Stopping Mininet - PASS (tick)
  • 13.23 Copying karaf logs - PASS (tick)

...

  • 23.1 Apply cell to environment - PASS (tick)
  • 23.2 Uninstalling Atomix - PASS (tick)
  • 23.3 Uninstalling ONOS package - PASS (tick)
  • 23.4 Installing Atomix - PASS (tick)
  • 23.5 Installing ONOS package - PASS (tick)
  • 23.6 Set up ONOS secure SSH - PASS (tick)
  • 23.7 Checking ONOS service - PASS (tick)
  • 23.8 Starting ONOS CLI sessions - PASS (tick)
  • 23.9 Checking ONOS nodes - PASS (tick)
  • 23.10 Checking ONOS applications - PASS (tick)
  • 23.11 Starting Mininet Topology - PASS (tick)
  • 23.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.13 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 23.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS (tick)
  • 23.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS (tick)
  • 23.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 23.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 23.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.19 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 23.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS (tick)
  • 23.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS (tick)
  • 23.22 Stopping Mininet - PASS (tick)
  • 23.23 Copying karaf logs - PASS (tick)

Case 33: Changing port configuration from untagged 10 to untagged 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 33.1 Apply cell to environment - PASS (tick)
  • 33.2 Uninstalling Atomix - PASS (tick)
  • 33.3 Uninstalling ONOS package - PASS (tick)
  • 33.4 Installing Atomix - PASS (tick)
  • 33.5 Installing ONOS package - PASS (tick)
  • 33.6 Set up ONOS secure SSH - PASS (tick)
  • 33.7 Checking ONOS service - PASS (tick)
  • 33.8 Starting ONOS CLI sessions - PASS (tick)
  • 33.9 Checking ONOS nodes - PASS (tick)
  • 33.10 Checking ONOS applications - PASS (tick)
  • 33.11 Starting Mininet Topology - PASS (tick)
  • 33.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 33.13 Check whether all flow status are ADDED - PASS (tick)
  • 33.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 33.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - PASS (tick)
  • 33.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 33.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 33.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 33.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 33.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 33.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS (tick)
  • 33.22 Stopping Mininet - PASS (tick)
  • 33.23 Copying karaf logs - PASS (tick)

...

  • 43.1 Apply cell to environment - PASS (tick)
  • 43.2 Uninstalling Atomix - PASS (tick)
  • 43.3 Uninstalling ONOS package - PASS (tick)
  • 43.4 Installing Atomix - PASS (tick)
  • 43.5 Installing ONOS package - PASS (tick)
  • 43.6 Set up ONOS secure SSH - PASS (tick)
  • 43.7 Checking ONOS service - PASS (tick)
  • 43.8 Starting ONOS CLI sessions - PASS (tick)
  • 43.9 Checking ONOS nodes - PASS (tick)
  • 43.10 Checking ONOS applications - PASS (tick)
  • 43.11 Starting Mininet Topology - PASS (tick)
  • 43.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 43.13 Check whether all flow status are ADDED - PASS (tick)
  • 43.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE43_Before - PASS (tick)
  • 43.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_Before - PASS (tick)
  • 43.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 43.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 43.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 43.19 Check whether all flow status are ADDED - PASS (tick)
  • 43.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_After - PASS (tick)
  • 43.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE43_After - PASS (tick)
  • 43.22 Stopping Mininet - PASS (tick)
  • 43.23 Copying karaf logs - PASS (tick)

Case 53: Changing port configuration from untagged 10 to tagged 20 with native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 53.1 Apply cell to environment - PASS (tick)
  • 53.2 Uninstalling Atomix - PASS (tick)
  • 53.3 Uninstalling ONOS package - PASS (tick)
  • 53.4 Installing Atomix - PASS (tick)
  • 53.5 Installing ONOS package - PASS (tick)
  • 53.6 Set up ONOS secure SSH - PASS (tick)
  • 53.7 Checking ONOS service - PASS (tick)
  • 53.8 Starting ONOS CLI sessions - PASS (tick)
  • 53.9 Checking ONOS nodes - PASS (tick)
  • 53.10 Checking ONOS applications - PASS (tick)
  • 53.11 Starting Mininet Topology - PASS (tick)
  • 53.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 53.13 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • PASS (tick)
  • 53.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_Before - PASS (tick)
  • 53.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_Before - PASS (tick)
  • 53.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 53.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 53.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 53.19 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 53.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_After - PASS (tick)
  • 53.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_After - PASS (tick)
  • 53.22 Stopping Mininet - PASS (tick)
  • 53.23 Copying karaf logs - PASS (tick)

...

  • 73.1 Apply cell to environment - PASS (tick)
  • 73.2 Uninstalling Atomix - PASS (tick)
  • 73.3 Uninstalling ONOS package - PASS (tick)
  • 73.4 Installing Atomix - PASS (tick)
  • 73.5 Installing ONOS package - PASS (tick)
  • 73.6 Set up ONOS secure SSH - PASS (tick)
  • 73.7 Checking ONOS service - PASS (tick)
  • 73.8 Starting ONOS CLI sessions - PASS (tick)
  • 73.9 Checking ONOS nodes - PASS (tick)
  • 73.10 Checking ONOS applications - PASS (tick)
  • 73.11 Starting Mininet Topology - PASS (tick)
  • 73.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 73.13 Check whether all flow status are ADDED - PASS (tick)
  • 73.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE73_Before - PASS (tick)
  • 73.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE73_Before - PASS (tick)
  • 73.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 73.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 73.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 73.19 Check whether all flow status are ADDED - PASS (tick)
  • 73.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE73_After - PASS (tick)
  • 73.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE73_After - PASS (tick)
  • 73.22 Stopping Mininet - PASS (tick)
  • 73.23 Copying karaf logs - PASS (tick)

Case 83: Changing port configuration from tagged 20 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 83.1 Apply cell to environment - PASS (tick)
  • 83.2 Uninstalling Atomix - PASS (tick)
  • 83.3 Uninstalling ONOS package - PASS (tick)
  • 83.4 Installing Atomix - PASS (tick)
  • 83.5 Installing ONOS package - PASS (tick)
  • 83.6 Set up ONOS secure SSH - PASS (tick)
  • 83.7 Checking ONOS service - PASS (tick)
  • 83.8 Starting ONOS CLI sessions - PASS (tick)
  • 83.9 Checking ONOS nodes - PASS (tick)
  • 83.10 Checking ONOS applications - PASS (tick)
  • 83.11 Starting Mininet Topology - PASS (tick)
  • 83.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 83.13 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 83.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_Before - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 83.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_Before - PASS (tick)
  • 83.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
  • Flow count looks wrong: 20
  • 52 - PASS (tick)
  • 83.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 83.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 83.19 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • PASS (tick)
  • 83.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_After - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 83.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_After - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 83.22 Stopping Mininet - PASS (tick)
  • 83.23 Copying karaf logs - PASS (tick)

...

  • 103.1 Apply cell to environment - PASS (tick)
  • 103.2 Uninstalling Atomix - PASS (tick)
  • 103.3 Uninstalling ONOS package - PASS (tick)
  • 103.4 Installing Atomix - PASS (tick)
  • 103.5 Installing ONOS package - PASS (tick)
  • 103.6 Set up ONOS secure SSH - PASS (tick)
  • 103.7 Checking ONOS service - PASS (tick)
  • 103.8 Starting ONOS CLI sessions - PASS (tick)
  • 103.9 Checking ONOS nodes - PASS (tick)
  • 103.10 Checking ONOS applications - PASS (tick)
  • 103.11 Starting Mininet Topology - PASS (tick)
  • 103.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 103.13 Check whether all flow status are ADDED - PASS (tick)
  • 103.14 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_Before - PASS (tick)
  • 103.15 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 103.16 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 103.17 Check whether the flow count is bigger than 104 - PASS (tick)
  • 103.18 Check whether all flow status are ADDED - PASS (tick)
  • 103.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_After - PASS (tick)
  • 103.20 Stopping Mininet - PASS (tick)
  • 103.21 Copying karaf logs - PASS (tick)

Case 113: Changing port configuration from tagged 20 and native 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 113.1 Apply cell to environment - PASS (tick)
  • 113.2 Uninstalling Atomix - PASS (tick)
  • 113.3 Uninstalling ONOS package - PASS (tick)
  • 113.4 Installing Atomix - PASS (tick)
  • 113.5 Installing ONOS package - PASS (tick)
  • 113.6 Set up ONOS secure SSH - PASS (tick)
  • 113.7 Checking ONOS service - PASS (tick)
  • 113.8 Starting ONOS CLI sessions - PASS (tick)
  • 113.9 Checking ONOS nodes - PASS (tick)
  • 113.10 Checking ONOS applications - PASS (tick)
  • 113.11 Starting Mininet Topology - PASS (tick)
  • 113.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 113.13 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 113.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 113.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 113.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
  • Flow count looks wrong: 22
  • PASS (tick)
  • 113.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 113.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 113.19 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 113.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 113.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS (tick)
  • 113.22 Stopping Mininet - PASS (tick)
  • 113.23 Copying karaf logs - PASS (tick)

...

  • 173.1 Apply cell to environment - PASS (tick)
  • 173.2 Uninstalling Atomix - PASS (tick)
  • 173.3 Uninstalling ONOS package - PASS (tick)
  • 173.4 Installing Atomix - PASS (tick)
  • 173.5 Installing ONOS package - PASS (tick)
  • 173.6 Set up ONOS secure SSH - PASS (tick)
  • 173.7 Checking ONOS service - PASS (tick)
  • 173.8 Starting ONOS CLI sessions - PASS (tick)
  • 173.9 Checking ONOS nodes - PASS (tick)
  • 173.10 Checking ONOS applications - PASS (tick)
  • 173.11 Starting Mininet Topology - PASS (tick)
  • 173.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 173.13 Check whether all flow status are ADDED - PASS (tick)
  • 173.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE173_Before - PASS (tick)
  • 173.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE173_Before - PASS (tick)
  • 173.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 173.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 173.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 173.19 Check whether all flow status are ADDED - PASS (tick)
  • 173.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE173_After - PASS (tick)
  • 173.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE173_After - PASS (tick)
  • 173.22 Stopping Mininet - PASS (tick)
  • 173.23 Copying karaf logs - PASS (tick)

Case 183: Changing port configuration from tagged 20 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 183.1 Apply cell to environment - PASS (tick)
  • 183.2 Uninstalling Atomix - PASS (tick)
  • 183.3 Uninstalling ONOS package - PASS (tick)
  • 183.4 Installing Atomix - PASS (tick)
  • 183.5 Installing ONOS package - PASS (tick)
  • 183.6 Set up ONOS secure SSH - PASS (tick)
  • 183.7 Checking ONOS service - PASS (tick)
  • 183.8 Starting ONOS CLI sessions - PASS (tick)
  • 183.9 Checking ONOS nodes - PASS (tick)
  • 183.10 Checking ONOS applications - PASS (tick)
  • 183.11 Starting Mininet Topology - PASS (tick)
  • 183.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 183.13 Check whether all flow status are ADDED - PASS (tick)
  • 183.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 183.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_Before - PASS (tick)
  • 183.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 183.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 183.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 183.19 Check whether all flow status are ADDED - PASS (tick)
  • 183.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 183.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_After - PASS (tick)
  • 183.22 Stopping Mininet - PASS (tick)
  • 183.23 Copying karaf logs - PASS (tick)

Case 193: Changing port configuration from tagged 20 and native 10 to untagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 193.1 Apply cell to environment - PASS (tick)
  • 193.2 Uninstalling Atomix - PASS (tick)
  • 193.3 Uninstalling ONOS package - PASS (tick)
  • 193.4 Installing Atomix - PASS (tick)
  • 193.5 Installing ONOS package - PASS (tick)
  • 193.6 Set up ONOS secure SSH - PASS (tick)
  • 193.7 Checking ONOS service - PASS (tick)
  • 193.8 Starting ONOS CLI sessions - PASS (tick)
  • 193.9 Checking ONOS nodes - PASS (tick)
  • 193.10 Checking ONOS applications - PASS (tick)
  • 193.11 Starting Mininet Topology - PASS (tick)
  • 193.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 193.13 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 193.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE193_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 193.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE193_Before - PASS (tick)
  • 193.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 20
  • 193.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 193.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 193.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 193.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE193_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 193.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE193_After - PASS (tick)
  • 193.22 Stopping Mininet - PASS (tick)
  • 193.23 Copying karaf logs - PASS (tick)

...

  • 203.1 Apply cell to environment - PASS (tick)
  • 203.2 Uninstalling Atomix - PASS (tick)
  • 203.3 Uninstalling ONOS package - PASS (tick)
  • 203.4 Installing Atomix - PASS (tick)
  • 203.5 Installing ONOS package - PASS (tick)
  • 203.6 Set up ONOS secure SSH - PASS (tick)
  • 203.7 Checking ONOS service - PASS (tick)
  • 203.8 Starting ONOS CLI sessions - PASS (tick)
  • 203.9 Checking ONOS nodes - PASS (tick)
  • 203.10 Checking ONOS applications - PASS (tick)
  • 203.11 Starting Mininet Topology - PASS (tick)
  • 203.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 203.13 Check whether all flow status are ADDED - PASS (tick)
  • 203.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_Before - PASS (tick)
  • 203.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_Before - PASS (tick)
  • 203.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 203.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 203.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 203.19 Check whether all flow status are ADDED - PASS (tick)
  • 203.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_After - PASS (tick)
  • 203.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_After - PASS (tick)
  • 203.22 Stopping Mininet - PASS (tick)
  • 203.23 Copying karaf logs - PASS (tick)

Case 213: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 213.1 Apply cell to environment - PASS (tick)
  • 213.2 Uninstalling Atomix - PASS (tick)
  • 213.3 Uninstalling ONOS package - PASS (tick)
  • 213.4 Installing Atomix - PASS (tick)
  • 213.5 Installing ONOS package - PASS (tick)
  • 213.6 Set up ONOS secure SSH - PASS (tick)
  • 213.7 Checking ONOS service - PASS (tick)
  • 213.8 Starting ONOS CLI sessions - PASS (tick)
  • 213.9 Checking ONOS nodes - PASS (tick)
  • 213.10 Checking ONOS applications - PASS (tick)
  • 213.11 Starting Mininet Topology - PASS (tick)
  • 213.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 213.13 Check whether all flow status are ADDED - PASS (tick)
  • 213.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 213.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_Before - PASS (tick)
  • 213.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 213.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 213.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 213.19 Check whether all flow status are ADDED - PASS (tick)
  • 213.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 213.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_After - PASS (tick)
  • 213.22 Stopping Mininet - PASS (tick)
  • 213.23 Copying karaf logs - PASS (tick)

...

  • 243.1 Apply cell to environment - PASS (tick)
  • 243.2 Uninstalling Atomix - PASS (tick)
  • 243.3 Uninstalling ONOS package - PASS (tick)
  • 243.4 Installing Atomix - PASS (tick)
  • 243.5 Installing ONOS package - PASS (tick)
  • 243.6 Set up ONOS secure SSH - PASS (tick)
  • 243.7 Checking ONOS service - PASS (tick)
  • 243.8 Starting ONOS CLI sessions - PASS (tick)
  • 243.9 Checking ONOS nodes - PASS (tick)
  • 243.10 Checking ONOS applications - PASS (tick)
  • 243.11 Starting Mininet Topology - PASS (tick)
  • 243.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 243.13 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 243.14 Verify full connectivity for [u'h1', u'h2', u'h5'] with tag CASE243_Before - FAIL (error)
    • IP connectivity failed
  • 243.15 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 243.16 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 243.17 Check whether the flow count is bigger than 104 - PASS (tick)
  • 243.18 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 243.19 Verify full connectivity for [u'h1', u'h2', u'h5'] with tag CASE243_After - FAIL (error)
    • IP connectivity failed
  • 243.20 Stopping Mininet - PASS (tick)
  • 243.21 Copying karaf logs - PASS (tick)