Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://onos-jenkins.onlab.us/job/FUNCovsdbtest/937/

...

commit 3142f646ac879eacd25daa1ec22f6c8e14069ceb (HEAD, origin/master, origin/HEAD, master)
Author: Yuta HIGUCHI [y-higuchi@ak.jp.nec.com]
AuthorDate: Wed Jun 7 11:12:45 2017 -0700
Commit: Yuta HIGUCHI [y-higuchi@onlab.us]
CommitDate: Fri Jun 9 17:27:31 2017 +0000

Avoid accidental link type override

Case 1: Setting up test environment - PASS

Setup the test environment including installing ONOS, start ONOS.

  • 1.1 Constructing test variables - No Result (warning)
  • 1.2 Uninstalling ONOS package - PASS (tick)
  • 1.3 Create cell file - No Result (warning)
  • 1.4 Apply cell to environment - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing ONOS package - PASS (tick)
  • 1.7 Set up ONOS secure SSH - PASS (tick)
  • 1.8 Starting ONOS service - PASS (tick)
  • 1.9 Starting ONOS CLI sessions - PASS (tick)
  • 1.10 App Ids check - PASS (tick)
  • 1.11 Install onos-ovsdb - PASS (tick)
  • 1.12 Install onos-app-vtn - PASS (tick)

Case 3: Test default br-int configuration and vxlan port - FAIL

onos create default br-int bridge and vxlan port on the ovsdb node

  • 3.1 ovsdb node 1 set ovs manager to 10.128.20.11 - PASS (tick)
  • 3.2 ovsdb node 2 set ovs manager to 10.128.20.11 - PASS (tick)
  • 3.3 Check ovsdb node 1 manager is 10.128.20.11 - PASS (tick)
  • 3.4 Check ovsdb node 2 manager is 10.128.20.11 - PASS (tick)
  • 3.5 Check default br-int bridge on ovsdb node 10.128.10.11 - FAIL (error)
    • onos add default bridge on the node 1 failed
  • 3.6 Check default br-int bridge on ovsdb node 10.128.20.11 - FAIL (error)
    • onos add default bridge on the node 2 failed
  • 3.7 Check default vxlan port on ovsdb node 10.128.10.11 - FAIL (error)
    • onos add default vxlan port on the node 1 failed
  • 3.8 Check default vxlan port on ovsdb node 10.128.20.11 - FAIL (error)
    • onos add default vxlan port on the node 2 failed

Case 4: - PASS

  • 4.1 ovsdb node 1 set ovs manager to 10.128.20.11 - PASS (tick)
  • 4.2 ovsdb node 2 set ovs manager to 10.128.20.11 - PASS (tick)
  • 4.3 Check ovsdb node 1 manager is 10.128.20.11 - PASS (tick)
  • 4.4 Check ovsdb node 2 manager is 10.128.20.11 - PASS (tick)
  • 4.5 Check ovsdb node 1 bridge br-int controller set to 10.128.20.11 - PASS (tick)
  • 4.6 Check ovsdb node 2 bridge br-int controller set to 10.128.20.11 - PASS (tick)
  • 4.7 Check onoscli devices have ovs 10.128.10.11 - PASS (tick)
  • 4.8 Check onoscli devices have ovs 10.128.20.11 - PASS (tick)

Case 2: Test ovsdb connection and teardown - PASS

Test ovsdb connection create and delete over ovsdb node and onos node

  • 2.1 Set ovsdb node manager - PASS (tick)
  • 2.2 Check ovsdb node manager is 10.128.20.11 - PASS (tick)
  • 2.3 Delete ovsdb node manager - PASS (tick)
  • 2.4 Check ovsdb node delete manager 10.128.20.11 - PASS (tick)

Case 5: - FAIL

  • 5.1 ovsdb node 1 set ovs manager to onos - PASS (tick)
  • 5.2 Check ovsdb node 1 manager is 10.128.20.11 - PASS (tick)
  • 5.3 Check ovsdb node 1 bridge br-int default flows on 10.128.10.11 - FAIL (error)