Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRDynamicConf_onos-2.2_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0">

commit 8e0e2946a12c3bfc7fee72997403103b41ffefff bed5cd95ae3d05cd6170d427d581129e1d1d2e7a (HEAD -] onos-2.2, origin/onos-2.2)
Author: Yi Tseng [yi@opennetworking.orgONOS Jenkins User [jenkins@onlab.us]
AuthorDate: Mon Fri Jun 8 1712 18:1048:56 05 2020 +08000000
Commit: Carmelo Cascone [carmelo@opennetworking.orgONOS Jenkins User [jenkins@onlab.us]
CommitDate: Tue Fri Jun 9 0212 18:2848:35 05 2020 +0000
[AETHER-239] Add RAW_DEVICE_CONFIG extension
--
(cherry picked from commit 40e0a0c90d9a3b8ea36ef2ecd0fc8763e0b3d482)
Starting snapshot 2.2.3-SNAPSHOT

Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

...

  • 13.1 Constructing test variables - PASS (tick)
  • 13.2 Apply cell to environment - PASS (tick)
  • 13.3 Uninstalling Atomix - PASS (tick)
  • 13.4 Uninstalling ONOS package - PASS (tick)
  • 13.5 Creating ONOS package - PASS (tick)
  • 13.6 Installing Atomix - PASS (tick)
  • 13.7 Installing ONOS package - PASS (tick)
  • 13.8 Set up ONOS secure SSH - PASS (tick)
  • 13.9 Checking ONOS service - PASS (tick)
  • 13.10 Starting ONOS CLI sessions - PASS (tick)
  • 13.11 Checking ONOS nodes - PASS (tick)
  • 13.12 Checking ONOS applications - PASS (tick)
  • 13.13 Starting Mininet Topology - PASS (tick)
  • 13.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.15 Check whether all flow status are ADDED - PASS (tick)
  • 13.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - PASS (tick)
  • 13.17 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 13.18 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 13.19 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.20 Check whether all flow status are ADDED - PASS (tick)
  • 13.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - PASS (tick)
  • 13.22 Stopping Mininet - PASS (tick)
  • 13.23 Copying karaf logs - PASS (tick)

Case 23: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 23.1 Apply cell to environment - PASS (tick)
  • 23.2 Uninstalling Atomix - PASS (tick)
  • 23.3 Uninstalling ONOS package - PASS (tick)
  • 23.4 Installing Atomix - PASS (tick)
  • 23.5 Installing ONOS package - PASS (tick)
  • 23.6 Set up ONOS secure SSH - PASS (tick)
  • 23.7 Checking ONOS service - PASS (tick)
  • 23.8 Starting ONOS CLI sessions - PASS (tick)
  • 23.9 Checking ONOS nodes - PASS (tick)
  • 23.10 Checking ONOS applications - PASS (tick)
  • 23.11 Starting Mininet Topology - PASS (tick)
  • 23.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.13 Check whether all flow status are ADDED - PASS (tick)
  • 23.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 23.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS (tick)
  • 23.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 23.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 23.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 23.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS (tick)
  • 23.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 23.22 Stopping Mininet - PASS (tick)
  • 23.23 Copying karaf logs - PASS (tick)

Case 33: Changing port configuration from untagged 10 to untagged 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 33.1 Apply cell to environment - PASS (tick)
  • 33.2 Uninstalling Atomix - PASS (tick)
  • 33.3 Uninstalling ONOS package - PASS (tick)
  • 33.4 Installing Atomix - PASS (tick)
  • 33.5 Installing ONOS package - PASS (tick)
  • 33.6 Set up ONOS secure SSH - PASS (tick)
  • 33.7 Checking ONOS service - PASS (tick)
  • 33.8 Starting ONOS CLI sessions - PASS (tick)
  • 33.9 Checking ONOS nodes - PASS (tick)
  • 33.10 Checking ONOS applications - PASS (tick)
  • 33.11 Starting Mininet Topology - PASS (tick)
  • 33.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 33.13 Check whether all flow status are ADDED - PASS (tick)
  • 33.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - PASS (tick)
  • 33.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - PASS (tick)
  • 33.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 33.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 33.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 33.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 33.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - PASS (tick)
  • 33.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS (tick)
  • 33.22 Stopping Mininet - PASS (tick)
  • 33.23 Copying karaf logs - PASS (tick)

...

  • 43.1 Apply cell to environment - PASS (tick)
  • 43.2 Uninstalling Atomix - PASS (tick)
  • 43.3 Uninstalling ONOS package - PASS (tick)
  • 43.4 Installing Atomix - PASS (tick)
  • 43.5 Installing ONOS package - PASS (tick)
  • 43.6 Set up ONOS secure SSH - PASS (tick)
  • 43.7 Checking ONOS service - PASS (tick)
  • 43.8 Starting ONOS CLI sessions - PASS (tick)
  • 43.9 Checking ONOS nodes - PASS (tick)
  • 43.10 Checking ONOS applications - PASS (tick)
  • 43.11 Starting Mininet Topology - PASS (tick)
  • 43.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 43.13 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • PASS (tick)
  • 43.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE43_Before - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 43.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_Before - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 43.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
  • Flow count looks wrong: 21
  • PASS (tick)
  • 43.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 43.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 43.19 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 43.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_After - PASS (tick)
  • 43.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE43_After - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 43.22 Stopping Mininet - PASS (tick)
  • 43.23 Copying karaf logs - PASS (tick)

...

  • 93.1 Apply cell to environment - PASS (tick)
  • 93.2 Uninstalling Atomix - PASS (tick)
  • 93.3 Uninstalling ONOS package - PASS (tick)
  • 93.4 Installing Atomix - PASS (tick)
  • 93.5 Installing ONOS package - PASS (tick)
  • 93.6 Set up ONOS secure SSH - PASS (tick)
  • 93.7 Checking ONOS service - PASS (tick)
  • 93.8 Starting ONOS CLI sessions - PASS (tick)
  • 93.9 Checking ONOS nodes - PASS (tick)
  • 93.10 Checking ONOS applications - PASS (tick)
  • 93.11 Starting Mininet Topology - PASS (tick)
  • 93.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 93.13 Check whether all flow status are ADDED - PASS (tick)
  • 93.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_Before - PASS (tick)
  • 93.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_Before - PASS (tick)
  • 93.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 93.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 93.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 93.19 Check whether all flow status are ADDED - PASS (tick)
  • 93.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_After - PASS (tick)
  • 93.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_After - PASS (tick)
  • 93.22 Stopping Mininet - PASS (tick)
  • 93.23 Copying karaf logs - PASS (tick)

Case 103: Changing port configuration from tagged 10 and native 20 to untagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 103.1 Apply cell to environment - PASS (tick)
  • 103.2 Uninstalling Atomix - PASS (tick)
  • 103.3 Uninstalling ONOS package - PASS (tick)
  • 103.4 Installing Atomix - PASS (tick)
  • 103.5 Installing ONOS package - PASS (tick)
  • 103.6 Set up ONOS secure SSH - PASS (tick)
  • 103.7 Checking ONOS service - PASS (tick)
  • 103.8 Starting ONOS CLI sessions - PASS (tick)
  • 103.9 Checking ONOS nodes - PASS (tick)
  • 103.10 Checking ONOS applications - PASS (tick)
  • 103.11 Starting Mininet Topology - PASS (tick)
  • 103.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 103.13 Check whether all flow status are ADDED - PASS (tick)
  • 103.14 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_Before - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 103.15 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 103.16 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 103.17 Check whether the flow count is bigger than 104 - PASS (tick)
  • 103.18 Check whether all flow status are ADDED - PASS (tick)
  • 103.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_After - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 103.20 Stopping Mininet - PASS (tick)
  • 103.21 Copying karaf logs - PASS (tick)

...

  • 123.1 Apply cell to environment - PASS (tick)
  • 123.2 Uninstalling Atomix - PASS (tick)
  • 123.3 Uninstalling ONOS package - PASS (tick)
  • 123.4 Installing Atomix - PASS (tick)
  • 123.5 Installing ONOS package - PASS (tick)
  • 123.6 Set up ONOS secure SSH - PASS (tick)
  • 123.7 Checking ONOS service - PASS (tick)
  • 123.8 Starting ONOS CLI sessions - PASS (tick)
  • 123.9 Checking ONOS nodes - PASS (tick)
  • 123.10 Checking ONOS applications - PASS (tick)
  • 123.11 Starting Mininet Topology - PASS (tick)
  • 123.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 123.13 Check whether all flow status are ADDED - PASS (tick)
  • 123.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_Before - PASS (tick)
  • 123.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_Before - PASS (tick)
  • 123.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 123.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 123.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 123.19 Check whether all flow status are ADDED - PASS (tick)
  • 123.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_After - PASS (tick)
  • 123.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_After - PASS (tick)
  • 123.22 Stopping Mininet - PASS (tick)
  • 123.23 Copying karaf logs - PASS (tick)

Case 133: Changing port configuration from tagged 20 and native 10 to tagged 120 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 133.1 Apply cell to environment - PASS (tick)
  • 133.2 Uninstalling Atomix - PASS (tick)
  • 133.3 Uninstalling ONOS package - PASS (tick)
  • 133.4 Installing Atomix - PASS (tick)
  • 133.5 Installing ONOS package - PASS (tick)
  • 133.6 Set up ONOS secure SSH - PASS (tick)
  • 133.7 Checking ONOS service - PASS (tick)
  • 133.8 Starting ONOS CLI sessions - PASS (tick)
  • 133.9 Checking ONOS nodes - PASS (tick)
  • 133.10 Checking ONOS applications - PASS (tick)
  • 133.11 Starting Mininet Topology - PASS (tick)
  • 133.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 133.13 Check whether all flow status are ADDED - PASS (tick)
  • 133.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE133_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 133.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE133_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 133.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 133.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 133.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 133.19 Check whether all flow status are ADDED - PASS (tick)
  • 133.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE133_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 133.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE133_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 133.22 Stopping Mininet - PASS (tick)
  • 133.23 Copying karaf logs - PASS (tick)

...

  • 153.1 Apply cell to environment - PASS (tick)
  • 153.2 Uninstalling Atomix - PASS (tick)
  • 153.3 Uninstalling ONOS package - PASS (tick)
  • 153.4 Installing Atomix - PASS (tick)
  • 153.5 Installing ONOS package - PASS (tick)
  • 153.6 Set up ONOS secure SSH - PASS (tick)
  • 153.7 Checking ONOS service - PASS (tick)
  • 153.8 Starting ONOS CLI sessions - PASS (tick)
  • 153.9 Checking ONOS nodes - PASS (tick)
  • 153.10 Checking ONOS applications - PASS (tick)
  • 153.11 Starting Mininet Topology - PASS (tick)
  • 153.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 153.13 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 153.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE153_Before - FAIL (error)
    • IP connectivity failed
  • 153.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE153_Before - PASS (tick)
  • 153.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL (error)
    • Flow count looks wrong: 19
  • PASS (tick)
  • 153.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 153.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 153.19 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 153.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE153_After - FAIL (error)
    • IP connectivity failed
  • 153.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE153_After - PASS (tick)
  • 153.22 Stopping Mininet - PASS (tick)
  • 153.23 Copying karaf logs - PASS (tick)

Case 163: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 163.1 Apply cell to environment - PASS (tick)
  • 163.2 Uninstalling Atomix - PASS (tick)
  • 163.3 Uninstalling ONOS package - PASS (tick)
  • 163.4 Installing Atomix - PASS (tick)
  • 163.5 Installing ONOS package - PASS (tick)
  • 163.6 Set up ONOS secure SSH - PASS (tick)
  • 163.7 Checking ONOS service - PASS (tick)
  • 163.8 Starting ONOS CLI sessions - PASS (tick)
  • 163.9 Checking ONOS nodes - PASS (tick)
  • 163.10 Checking ONOS applications - PASS (tick)
  • 163.11 Starting Mininet Topology - PASS (tick)
  • 163.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 163.13 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 163.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE163_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 163.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_Before - PASS (tick)
  • 163.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 18
  • 163.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 163.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 163.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 163.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE163_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 163.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_After - PASS (tick)
  • 163.22 Stopping Mininet - PASS (tick)
  • 163.23 Copying karaf logs - PASS (tick)

Case 173: Changing port configuration from tagged 20 to tagged 120, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 173.1 Apply cell to environment - PASS (tick)
  • 173.2 Uninstalling Atomix - PASS (tick)
  • 173.3 Uninstalling ONOS package - PASS (tick)
  • 173.4 Installing Atomix - PASS (tick)
  • 173.5 Installing ONOS package - PASS (tick)
  • 173.6 Set up ONOS secure SSH - PASS (tick)
  • 173.7 Checking ONOS service - PASS (tick)
  • 173.8 Starting ONOS CLI sessions - PASS (tick)
  • 173.9 Checking ONOS nodes - PASS (tick)
  • 173.10 Checking ONOS applications - PASS (tick)
  • 173.11 Starting Mininet Topology - PASS (tick)
  • 173.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 173.13 Check whether all flow status are ADDED - PASS (tick)
  • 173.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE173_Before - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 173.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE173_Before - PASS (tick)
  • 173.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 173.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 173.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 173.19 Check whether all flow status are ADDED - PASS (tick)
  • 173.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE173_After - PASS (tick)
  • 173.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE173_After - PASS (tick)
  • 173.22 Stopping Mininet - PASS (tick)
  • 173.23 Copying karaf logs - PASS (tick)

Case 183: Changing port configuration from tagged 20 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 183.1 Apply cell to environment - PASS (tick)
  • 183.2 Uninstalling Atomix - PASS (tick)
  • 183.3 Uninstalling ONOS package - PASS (tick)
  • 183.4 Installing Atomix - PASS (tick)
  • 183.5 Installing ONOS package - PASS (tick)
  • 183.6 Set up ONOS secure SSH - PASS (tick)
  • 183.7 Checking ONOS service - PASS (tick)
  • 183.8 Starting ONOS CLI sessions - PASS (tick)
  • 183.9 Checking ONOS nodes - PASS (tick)
  • 183.10 Checking ONOS applications - PASS (tick)
  • 183.11 Starting Mininet Topology - PASS (tick)
  • 183.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 183.13 Check whether all flow status are ADDED - PASS (tick)
  • 183.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 183.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_Before - PASS (tick)
  • 183.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 183.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 183.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 183.19 Check whether all flow status are ADDED - PASS (tick)
  • 183.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 183.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_After - PASS (tick)
  • 183.22 Stopping Mininet - PASS (tick)
  • 183.23 Copying karaf logs - PASS (tick)

...

  • 193.1 Apply cell to environment - PASS (tick)
  • 193.2 Uninstalling Atomix - PASS (tick)
  • 193.3 Uninstalling ONOS package - PASS (tick)
  • 193.4 Installing Atomix - PASS (tick)
  • 193.5 Installing ONOS package - PASS (tick)
  • 193.6 Set up ONOS secure SSH - PASS (tick)
  • 193.7 Checking ONOS service - PASS (tick)
  • 193.8 Starting ONOS CLI sessions - PASS (tick)
  • 193.9 Checking ONOS nodes - PASS (tick)
  • 193.10 Checking ONOS applications - PASS (tick)
  • 193.11 Starting Mininet Topology - PASS (tick)
  • 193.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 193.13 Check whether all flow status are ADDED - PASS (tick)
  • 193.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE193_Before - PASS (tick)
  • 193.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE193_Before - PASS (tick)
  • 193.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 193.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 193.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 193.19 Check whether all flow status are ADDED - PASS (tick)
  • 193.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE193_After - PASS (tick)
  • 193.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE193_After - PASS (tick)
  • 193.22 Stopping Mininet - PASS (tick)
  • 193.23 Copying karaf logs - PASS (tick)

Case 203: Changing port configuration from tagged 20 and native 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 203.1 Apply cell to environment - PASS (tick)
  • 203.2 Uninstalling Atomix - PASS (tick)
  • 203.3 Uninstalling ONOS package - PASS (tick)
  • 203.4 Installing Atomix - PASS (tick)
  • 203.5 Installing ONOS package - PASS (tick)
  • 203.6 Set up ONOS secure SSH - PASS (tick)
  • 203.7 Checking ONOS service - PASS (tick)
  • 203.8 Starting ONOS CLI sessions - PASS (tick)
  • 203.9 Checking ONOS nodes - PASS (tick)
  • 203.10 Checking ONOS applications - PASS (tick)
  • 203.11 Starting Mininet Topology - PASS (tick)
  • 203.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 203.13 Check whether all flow status are ADDED - PASS (tick)
  • 203.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_Before - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 203.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_Before - PASS (tick)
  • 203.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 203.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 203.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 203.19 Check whether all flow status are ADDED - PASS (tick)
  • 203.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_After - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 203.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_After - PASS (tick)
  • 203.22 Stopping Mininet - PASS (tick)
  • 203.23 Copying karaf logs - PASS (tick)

...

  • 213.1 Apply cell to environment - PASS (tick)
  • 213.2 Uninstalling Atomix - PASS (tick)
  • 213.3 Uninstalling ONOS package - PASS (tick)
  • 213.4 Installing Atomix - PASS (tick)
  • 213.5 Installing ONOS package - PASS (tick)
  • 213.6 Set up ONOS secure SSH - PASS (tick)
  • 213.7 Checking ONOS service - PASS (tick)
  • 213.8 Starting ONOS CLI sessions - PASS (tick)
  • 213.9 Checking ONOS nodes - PASS (tick)
  • 213.10 Checking ONOS applications - PASS (tick)
  • 213.11 Starting Mininet Topology - PASS (tick)
  • 213.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 213.13 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • PASS (tick)
  • 213.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_Before - FAIL (error)
    • IP connectivity failed
  • 213.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_Before - PASS (tick)
  • 213.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 20
  • PASS (tick)
  • 213.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 213.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 213.19 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 213.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_After - FAIL (error)
    • IP connectivity failed
  • 213.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_After - PASS (tick)
  • 213.22 Stopping Mininet - PASS (tick)
  • 213.23 Copying karaf logs - PASS (tick)

...