Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRBridging-stratum_onos-2.2_20-builds_graph.jpg", alt="SRBridging-stratum", style="width:525px;height:350px;border:0"> |
commit 0f1ffd162f0a8fd2a12ac26f12b54519064c4a3b 897d92d094473847a1a843b72a2b9946ad902a6e (HEAD -] onos-2.2, origin/onos-2.2)
Author: Yi Tseng Jian Li [yi@opennetworkingpyguni@gmail.orgcom]
AuthorDate: Fri Sep 18 11:10:47 2020 -0700Sun Nov 15 01:02:59 2020 +0900
Commit: Carmelo Cascone Jian Li [carmelo@opennetworkingpyguni@gmail.orgcom]
CommitDate: Tue Sep 22 18:51:09 2020 +0000
Add netcfg for INTSun Nov 15 02:06:41 2020 +0900
Support Kubernetes LoadBalancer service type
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, stratum switches and 3 ONOS instances - PASS
...
- 35.1 Apply cell to environment - PASS
- 35.2 Uninstalling Atomix - PASS
- 35.3 Uninstalling ONOS package - PASS
- 35.4 Create Cluster Config - PASS
- 35.5 Installing Atomix via docker containers - PASS
- 35.6 Installing ONOS via docker containers - PASS
- 35.7 Set up ONOS secure SSH - PASS
- 35.8 Starting ONOS CLI sessions - PASS
- 35.9 Checking ONOS nodes - PASS
- 35.10 Checking ONOS applications - PASS
- 35.11 Set logging levels - PASS
- 35.12 Set ONOS configurations - PASS
- 35.13 Starting Mininet Topology - PASS
- 35.14 Configure switches in ONOS - PASS
- 35.15 Check whether the flow count is bigger than 28 - PASS
- 35.16 Check whether all flow status are ADDED - PASS
- 35.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 28 - PASS
- 35.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE35 - PASS
- 35.19 Stopping Mininet - PASS
- 35.20 Copying karaf logs - PASS
Case 36: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with dual-homed ToR, stratum switches and 3 ONOS instances -
...
PASS
- 36.1 Apply cell to environment - PASS
- 36.2 Uninstalling Atomix - PASS
- 36.3 Uninstalling ONOS package - PASS
- 36.4 Create Cluster Config - PASS
- 36.5 Installing Atomix via docker containers - PASS
- 36.6 Installing ONOS via docker containers - PASS
- 36.7 Set up ONOS secure SSH - PASS
- 36.8 Starting ONOS CLI sessions - PASS
- 36.9 Checking ONOS nodes - PASS
- 36.10 Checking ONOS applications - PASS
- 36.11 Set logging levels - PASS
- 36.12 Set ONOS configurations - PASS
- 36.13 Starting Mininet Topology - PASS
- 36.14 Configure switches in ONOS - PASS
- 36.15 Check whether the flow count is bigger than 74 - FAIL Flow count looks wrong; found 60, expecting at least 74
- PASS
- 36.16 Check whether all flow status are ADDED - PASS
- 36.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 37 - PASS
- 36.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 37 - FAIL Flow count looks wrong: 4
- PASS
- 36.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE36 - FAIL IP connectivity failed
- PASS
- 36.20 Stopping Mininet - PASS
- 36.21 Copying karaf logs - PASS
...