- 17.1 Apply cell to environment - PASS
- 17.2 Uninstalling Atomix - PASS
- 17.3 Uninstalling ONOS package - PASS
- 17.4 Create Cluster Config - PASS
- 17.5 Installing Atomix via docker containers - PASS
- 17.6 Installing ONOS via docker containers - PASS
- 17.7 Set up ONOS secure SSH - PASS
- 17.8 Starting ONOS CLI sessions - PASS
- 17.9 Checking ONOS nodes - PASS
- 17.10 Checking ONOS applications - PASS
- 17.11 Set logging levels - PASS
- 17.12 Set ONOS configurations - PASS
- 17.13 Starting Mininet Topology - PASS
- 17.14 Configure switches in ONOS - PASS
- 17.15 Check whether the flow count is bigger than 64 - PASS
- 17.16 Check whether all flow status are ADDED - PASS
- 17.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 32 - PASS
- 17.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 32 - PASS
- 17.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - PASS
- 17.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - PASS
- 17.21 Stopping Mininet - PASS
- 17.22 Copying karaf logs - PASS
Case 18: Bridging test between two tagged hosts, with 2x4 dual-homed leaf-spine topology, stratum switches and 3 ONOS instances -
...
PASS
- 18.1 Apply cell to environment - PASS
- 18.2 Uninstalling Atomix - PASS
- 18.3 Uninstalling ONOS package - PASS
- 18.4 Create Cluster Config - PASS
- 18.5 Installing Atomix via docker containers - PASS
- 18.6 Installing ONOS via docker containers - PASS
- 18.7 Set up ONOS secure SSH - PASS
- 18.8 Starting ONOS CLI sessions - PASS
- 18.9 Checking ONOS nodes - PASS
- 18.10 Checking ONOS applications - PASS
- 18.11 Set logging levels - PASS
- 18.12 Set ONOS configurations - PASS
- 18.13 Starting Mininet Topology - PASS
- 18.14 Configure switches in ONOS - PASS
- 18.15 Check whether the flow count is bigger than 212 - PASS
- 18.16 Check whether all flow status are ADDED - PASS
- 18.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 53 - PASS
- 18.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 53 - PASS
- 18.19 Check whether the flow count of device device:bmv2:leaf3 is bigger than 53 - FAIL Flow count looks wrong: 22
- PASS
- 18.20 Check whether the flow count of device device:bmv2:leaf4 is bigger than 53 - PASS
- 18.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS
- 18.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - FAIL
- IP connectivity failed
- PASS
- 18.23 Stopping Mininet - PASS
- 18.24 Copying karaf logs - PASS
...
- 35.1 Apply cell to environment - PASS
- 35.2 Uninstalling Atomix - PASS
- 35.3 Uninstalling ONOS package - PASS
- 35.4 Create Cluster Config - PASS
- 35.5 Installing Atomix via docker containers - PASS
- 35.6 Installing ONOS via docker containers - PASS
- 35.7 Set up ONOS secure SSH - PASS
- 35.8 Starting ONOS CLI sessions - PASS
- 35.9 Checking ONOS nodes - PASS
- 35.10 Checking ONOS applications - PASS
- 35.11 Set logging levels - PASS
- 35.12 Set ONOS configurations - PASS
- 35.13 Starting Mininet Topology - PASS
- 35.14 Configure switches in ONOS - PASS
- 35.15 Check whether the flow count is bigger than 28 - PASS
- 35.16 Check whether all flow status are ADDED - PASS
- 35.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 28 - PASS
- 35.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE35 - PASS
- 35.19 Stopping Mininet - PASS
- 35.20 Copying karaf logs - PASS
Case 36: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with dual-homed ToR, stratum switches and 3 ONOS instances -
...
PASS
- 36.1 Apply cell to environment - PASS
- 36.2 Uninstalling Atomix - PASS
- 36.3 Uninstalling ONOS package - PASS
- 36.4 Create Cluster Config - PASS
- 36.5 Installing Atomix via docker containers - PASS
- 36.6 Installing ONOS via docker containers - PASS
- 36.7 Set up ONOS secure SSH - PASS
- 36.8 Starting ONOS CLI sessions - PASS
- 36.9 Checking ONOS nodes - PASS
- 36.10 Checking ONOS applications - PASS
- 36.11 Set logging levels - PASS
- 36.12 Set ONOS configurations - PASS
- 36.13 Starting Mininet Topology - PASS
- 36.14 Configure switches in ONOS - PASS
- 36.15 Check whether the flow count is bigger than 74 - PASS
- 36.16 Check whether all flow status are ADDED - PASS
- 36.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 37 - PASS
- 36.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 37 - FAIL Flow count looks wrong: 27
- PASS
- 36.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE36 - FAIL IP connectivity failed
- PASS
- 36.20 Stopping Mininet - PASS
- 36.21 Copying karaf logs - PASS
...
- 68.1 Apply cell to environment - PASS
- 68.2 Uninstalling Atomix - PASS
- 68.3 Uninstalling ONOS package - PASS
- 68.4 Create Cluster Config - PASS
- 68.5 Installing Atomix via docker containers - PASS
- 68.6 Installing ONOS via docker containers - PASS
- 68.7 Set up ONOS secure SSH - PASS
- 68.8 Starting ONOS CLI sessions - PASS
- 68.9 Checking ONOS nodes - PASS
- 68.10 Checking ONOS applications - PASS
- 68.11 Set logging levels - PASS
- 68.12 Set ONOS configurations - PASS
- 68.13 Starting Mininet Topology - PASS
- 68.14 Configure switches in ONOS - PASS
- 68.15 Check whether the flow count is bigger than 212 - PASS
- 68.16 Check whether all flow status are ADDED - PASS
- 68.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 53 - PASS
- 68.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 53 - PASS
- 68.19 Check whether the flow count of device device:bmv2:leaf3 is bigger than 53 - PASS
- 68.20 Check whether the flow count of device device:bmv2:leaf4 is bigger than 53 - PASS
- 68.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE68 - PASS
- 68.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE68 - PASS
- 68.23 Stopping Mininet - PASS
- 68.24 Copying karaf logs - PASS
Case 75: Bridging test between untagged and tagged hosts with different vlan id, with single ToR, stratum switches and 3 ONOS instances -
...
PASS
- 75.1 Apply cell to environment - PASS
- 75.2 Uninstalling Atomix - PASS
- 75.3 Uninstalling ONOS package - PASS
- 75.4 Create Cluster Config - PASS
- 75.5 Installing Atomix via docker containers - PASS
- 75.6 Installing ONOS via docker containers - PASS
- 75.7 Set up ONOS secure SSH - PASS
- 75.8 Starting ONOS CLI sessions - PASS
- 75.9 Checking ONOS nodes - PASS
- 75.10 Checking ONOS applications - PASS
- 75.11 Set logging levels - PASS
- 75.12 Set ONOS configurations - PASS
- 75.13 Starting Mininet Topology - PASS
- 75.14 Configure switches in ONOS - PASS
- 75.15 Check whether the flow count is bigger than 28 - FAIL Flow count looks wrong; found 15, expecting at least 28
- PASS
- 75.16 Check whether all flow status are ADDED - PASS
- 75.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 28 - FAIL Flow count looks wrong: 15
- PASS
- 75.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE75 - PASS
- 75.19 Stopping Mininet - PASS
- 75.20 Copying karaf logs - PASS
...