Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRBridging-stratum_onos-2.2_20-builds_graph.jpg", alt="SRBridging-stratum", style="width:525px;height:350px;border:0"> |
commit 759caf0a135e12d5b059e81bd06eaa0a337b385b 28d4e6f461ff4edb3d56d3e8d09fbb923506a5a2 (HEAD -] onos-2.2, origin/onos-2.2)
Author: ONOS Jenkins User [jenkins@onlab.usThomas Vachuska [tom@opennetworking.org]
AuthorDate: Mon Aug 3 02:17:28 2020 +0000Fri Jul 31 14:20:32 2020 -0700
Commit: ONOS Jenkins User [jenkins@onlab.usThomas Vachuska [tom@opennetworking.org]
CommitDate: Mon Aug 3 0215:1714:28 56 2020 +0000
Starting snapshot 2.2.4-SNAPSHOT-0700
Removing the host drop-shadow from the topo GUI2
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, stratum switches and 3 ONOS instances - PASS
...
- 47.1 Apply cell to environment - PASS
- 47.2 Uninstalling Atomix - PASS
- 47.3 Uninstalling ONOS package - PASS
- 47.4 Installing Atomix - PASS
- 47.5 Installing ONOS package - PASS
- 47.6 Set up ONOS secure SSH - PASS
- 47.7 Checking ONOS service - PASS
- 47.8 Starting ONOS CLI sessions - PASS
- 47.9 Checking ONOS nodes - PASS
- 47.10 Checking ONOS applications - PASS
- 47.11 Set logging levels - PASS
- 47.12 Set ONOS configurations - PASS
- 47.13 Starting Mininet Topology - PASS
- 47.14 Check whether the flow count is bigger than 64 - PASS
- 47.15 Check whether all flow status are ADDED - PASS
- 47.16 Check whether the flow count of device device:bmv2:leaf1 is bigger than 32 - PASS
- 47.17 Check whether the flow count of device device:bmv2:leaf2 is bigger than 32 - PASS
- 47.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - PASS
- 47.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - PASS
- 47.20 Stopping Mininet - PASS
- 47.21 Copying karaf logs - PASS
Case 48: Bridging test between untagged host and tagged host, with 2x4 dual-homed leaf-spine topology, stratum switches and 3 ONOS instances -
...
FAIL
- 48.1 Apply cell to environment - PASS
- 48.2 Uninstalling Atomix - PASS
- 48.3 Uninstalling ONOS package - PASS
- 48.4 Installing Atomix - PASS
- 48.5 Installing ONOS package - PASS
- 48.6 Set up ONOS secure SSH - PASS
- 48.7 Checking ONOS service - PASS
- 48.8 Starting ONOS CLI sessions - PASS
- 48.9 Checking ONOS nodes - PASS
- 48.10 Checking ONOS applications - PASS
- 48.11 Set logging levels - PASS
- 48.12 Set ONOS configurations - PASS
- 48.13 Starting Mininet Topology - PASS
- 48.14 Check whether the flow count is bigger than 212 - PASS
- 48.15 Check whether all flow status are ADDED - PASS
- 48.16 Check whether the flow count of device device:bmv2:leaf1 is bigger than 53 - PASS
- 48.17 Check whether the flow count of device device:bmv2:leaf2 is bigger than 53 - PASS
- 48.18 Check whether the flow count of device device:bmv2:leaf3 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 32
- 48.19 Check whether the flow count of device device:bmv2:leaf4 is bigger than 53 - PASS
- 48.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE48 - PASS
- 48.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE48 - PASS FAIL
- IP connectivity failed
- 48.22 Stopping Mininet - PASS
- 48.23 Copying karaf logs - PASS
...