  • 7.1 Apply cell to environment - PASS (tick)
  • 7.2 Uninstalling Atomix - PASS (tick)
  • 7.3 Uninstalling ONOS package - PASS (tick)
  • 7.4 Installing Atomix - PASS (tick)
  • 7.5 Installing ONOS package - PASS (tick)
  • 7.6 Set up ONOS secure SSH - PASS (tick)
  • 7.7 Checking ONOS service - PASS (tick)
  • 7.8 Starting ONOS CLI sessions - PASS (tick)
  • 7.9 Checking ONOS nodes - PASS (tick)
  • 7.10 Checking ONOS applications - PASS (tick)
  • 7.11 Set logging levels - PASS (tick)
  • 7.12 Set ONOS configurations - PASS (tick)
  • 7.13 Starting Mininet Topology - PASS (tick)
  • 7.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 7.15 Check whether all flow status are ADDED - PASS (tick)
  • 7.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 7.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 7.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS (tick)
  • 7.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS (tick)
  • 7.20 Stopping Mininet - PASS (tick)
  • 7.21 Copying karaf logs - PASS (tick)

Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances -

...

PASS

  • 8.1 Apply cell to environment - PASS (tick)
  • 8.2 Uninstalling Atomix - PASS (tick)
  • 8.3 Uninstalling ONOS package - PASS (tick)
  • 8.4 Installing Atomix - PASS (tick)
  • 8.5 Installing ONOS package - PASS (tick)
  • 8.6 Set up ONOS secure SSH - PASS (tick)
  • 8.7 Checking ONOS service - PASS (tick)
  • 8.8 Starting ONOS CLI sessions - PASS (tick)
  • 8.9 Checking ONOS nodes - PASS (tick)
  • 8.10 Checking ONOS applications - PASS (tick)
  • 8.11 Set logging levels - PASS (tick)
  • 8.12 Set ONOS configurations - PASS (tick)
  • 8.13 Starting Mininet Topology - PASS (tick)
  • 8.14 Check whether the flow count is bigger than 212 - PASS (tick)
  • 8.15 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 8.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 8.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL (error)
    • Flow count looks wrong: 25
  • PASS (tick)
  • 8.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 8.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 8.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 8.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - PASS (tick)
  • 8.22 Stopping Mininet - PASS (tick)
  • 8.23 Copying karaf logs - PASS (tick)

...

  • 17.1 Apply cell to environment - PASS (tick)
  • 17.2 Uninstalling Atomix - PASS (tick)
  • 17.3 Uninstalling ONOS package - PASS (tick)
  • 17.4 Installing Atomix - PASS (tick)
  • 17.5 Installing ONOS package - PASS (tick)
  • 17.6 Set up ONOS secure SSH - PASS (tick)
  • 17.7 Checking ONOS service - PASS (tick)
  • 17.8 Starting ONOS CLI sessions - PASS (tick)
  • 17.9 Checking ONOS nodes - PASS (tick)
  • 17.10 Checking ONOS applications - PASS (tick)
  • 17.11 Set logging levels - PASS (tick)
  • 17.12 Set ONOS configurations - PASS (tick)
  • 17.13 Starting Mininet Topology - PASS (tick)
  • 17.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 17.15 Check whether all flow status are ADDED - PASS (tick)
  • 17.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 17.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 17.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 17.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 17.20 Stopping Mininet - PASS (tick)
  • 17.21 Copying karaf logs - PASS (tick)

...

  • 26.1 Apply cell to environment - PASS (tick)
  • 26.2 Uninstalling Atomix - PASS (tick)
  • 26.3 Uninstalling ONOS package - PASS (tick)
  • 26.4 Installing Atomix - PASS (tick)
  • 26.5 Installing ONOS package - PASS (tick)
  • 26.6 Set up ONOS secure SSH - PASS (tick)
  • 26.7 Checking ONOS service - PASS (tick)
  • 26.8 Starting ONOS CLI sessions - PASS (tick)
  • 26.9 Checking ONOS nodes - PASS (tick)
  • 26.10 Checking ONOS applications - PASS (tick)
  • 26.11 Set logging levels - PASS (tick)
  • 26.12 Set ONOS configurations - PASS (tick)
  • 26.13 Starting Mininet Topology - PASS (tick)
  • 26.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 26.15 Check whether all flow status are ADDED - PASS (tick)
  • 26.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 26.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 26.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE26 - PASS (tick)
  • 26.19 Stopping Mininet - PASS (tick)
  • 26.20 Copying karaf logs - PASS (tick)

Case 27: Bridging test between two untagged hosts on vlan-native port, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -

...

FAIL

  • 27.1 Apply cell to environment - PASS (tick)
  • 27.2 Uninstalling Atomix - PASS (tick)
  • 27.3 Uninstalling ONOS package - PASS (tick)
  • 27.4 Installing Atomix - PASS (tick)
  • 27.5 Installing ONOS package - PASS (tick)
  • 27.6 Set up ONOS secure SSH - PASS (tick)
  • 27.7 Checking ONOS service - PASS (tick)
  • 27.8 Starting ONOS CLI sessions - PASS (tick)
  • 27.9 Checking ONOS nodes - PASS (tick)
  • 27.10 Checking ONOS applications - PASS (tick)
  • 27.11 Set logging levels - PASS (tick)
  • 27.12 Set ONOS configurations - PASS (tick)
  • 27.13 Starting Mininet Topology - PASS (tick)
  • 27.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 27.15 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 27.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 27.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 26
  • 27.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - PASS (tick)
  • 27.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 27.20 Stopping Mininet - PASS (tick)
  • 27.21 Copying karaf logs - PASS (tick)

...

  • 37.1 Apply cell to environment - PASS (tick)
  • 37.2 Uninstalling Atomix - PASS (tick)
  • 37.3 Uninstalling ONOS package - PASS (tick)
  • 37.4 Installing Atomix - PASS (tick)
  • 37.5 Installing ONOS package - PASS (tick)
  • 37.6 Set up ONOS secure SSH - PASS (tick)
  • 37.7 Checking ONOS service - PASS (tick)
  • 37.8 Starting ONOS CLI sessions - PASS (tick)
  • 37.9 Checking ONOS nodes - PASS (tick)
  • 37.10 Checking ONOS applications - PASS (tick)
  • 37.11 Set logging levels - PASS (tick)
  • 37.12 Set ONOS configurations - PASS (tick)
  • 37.13 Starting Mininet Topology - PASS (tick)
  • 37.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 37.15 Check whether all flow status are ADDED - PASS (tick)
  • 37.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 37.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 37.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - PASS (tick)
  • 37.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - PASS (tick)
  • 37.20 Stopping Mininet - PASS (tick)
  • 37.21 Copying karaf logs - PASS (tick)

Case 38: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances -

...

FAIL

  • 38.1 Apply cell to environment - PASS (tick)
  • 38.2 Uninstalling Atomix - PASS (tick)
  • 38.3 Uninstalling ONOS package - PASS (tick)
  • 38.4 Installing Atomix - PASS (tick)
  • 38.5 Installing ONOS package - PASS (tick)
  • 38.6 Set up ONOS secure SSH - PASS (tick)
  • 38.7 Checking ONOS service - PASS (tick)
  • 38.8 Starting ONOS CLI sessions - PASS (tick)
  • 38.9 Checking ONOS nodes - PASS (tick)
  • 38.10 Checking ONOS applications - PASS (tick)
  • 38.11 Set logging levels - PASS (tick)
  • 38.12 Set ONOS configurations - PASS (tick)
  • 38.13 Starting Mininet Topology - PASS (tick)
  • 38.14 Check whether the flow count is bigger than 212 - PASS (tick)
  • 38.15 Check whether all flow status are ADDED - PASS (tick)
  • 38.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 38.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 38.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 38.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 38.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE38 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 38.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE38 - PASS (tick)
  • 38.22 Stopping Mininet - PASS (tick)
  • 38.23 Copying karaf logs - PASS (tick)

...