Comment: Published from Jenkins build: https://onos-jenkins.onlab.us/job/Pipeline_postjob_VM/337/
FUNCnetCfg at 27 Sep 2017 1923:5433:2606

commit 47c954141de2eb1a237d7d024e99bd8bb64857b2 (HEAD, origin/master, origin/HEAD, master)
Author: Ray Milkey [ray@opennetworking.org]
AuthorDate: Fri Sep 15 10:40:48 2017 -0700
Commit: Thomas Vachuska [tom@opennetworking.org]
CommitDate: Wed Sep 27 17:23:10 2017 +0000

Refactor construction of application objects

Case 1: Pull onos branch and build onos on Teststation. - PASS

For loading from params file, and pull and build the latest ONOS package

  • 1.1 Constructing test variables - PASS (tick)

Case 25: Preparing network-cfg.json to load configurations - PASS

  • 25.1 Moving network-cfg.json to /home/sdn/onos/tools/package/config/ - PASS (tick)

Case 2: Starting up 3 node(s) ONOS cluster - PASS

Set up ONOS with 3 node(s) ONOS cluster

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling ONOS package - PASS (tick)
  • 2.3 Creating ONOS package - PASS (tick)
  • 2.4 Installing ONOS package - PASS (tick)
  • 2.5 Set up ONOS secure SSH - PASS (tick)
  • 2.6 Checking ONOS service - PASS (tick)
  • 2.7 Starting ONOS CLI sessions - PASS (tick)

Case 20: Add Network configurations to the cluster - PASS

Add Network Configurations for devices not discovered yet. One device is allowed, the other disallowed.

  • 20.1 Add Net Cfg for switch1 - PASS (tick)
  • 20.2 Add Net Cfg for switch3 - PASS (tick)
  • 20.3 Check net config - PASS (tick)

Case 11: Start Mininet topology with OF 1.3 switches - PASS

Start mininet topology with OF 1.3 switches to test intents, exits out if topology did not start correctly

  • 11.1 Starting Mininet topology with OF 1.3 switches - PASS (tick)

Case 27: Posting network configurations to the top level web resource - FAIL

  • 27.1 Get json object from Net Cfg - No Result (warning)
  • 27.2 Posting json object to Net Cfg - No Result (warning)
  • 27.3 Compare device with ONOS - No Result (warning)
  • 27.4 Check net config - PASS (tick)
  • 27.5 ONOS should only show devices S1, S2, S4, S5 and S6 - FAIL (error)
    • ONOS devices doesn't match the list of allowed devices.
    • Expected devices: ['of:0000000000000001', 'of:0000000000000002', 'of:0000000000000004', 'of:0000000000000005', 'of:0000000000000006']
    • Actual devices: []
  • 27.6 Modify json object so S6 is disallowed - PASS (tick)

Case 26: Check to see if the pre-startup configurations were set, then remove their allowed status - FAIL

  • 26.1 Checking configurations for Switches 5 and 6 - No Result (warning)
  • 26.2 ONOS should only show devices S1, S2, S4, and S5 - FAIL (error)
    • ONOS devices doesn't match the list of allowed devices
  • 26.3 Removing allowed status from Switches 5 and 6 - No Result (warning)

Case 21: Check Devices After they initially connect to ONOS - FAIL

  • 21.1 Check net config - FAIL (error)
    • Check Net Cfg failed. Check above messages.
  • 21.2 ONOS should only show devices S1, S2, and S4 - FAIL (error)
    • ONOS devices doesn't match the list of allowed devices
  • 21.3 Check device annotations - FAIL (error)
    • Incorrect annotations for configured devices.

Case 22: Add Network configurations for connected devices to the cluster - PASS

Add Network Configurations for discovered devices. One device is allowed, the other disallowed.

  • 22.1 Add Net Cfg for switch2 - PASS (tick)
  • 22.2 Add Net Cfg for switch4 - PASS (tick)
  • 22.3 Check net config - PASS (tick)

Case 23: Check Devices after all configurations are set - FAIL

  • 23.1 Check net config - PASS (tick)
  • 23.2 ONOS should only show devices S1 and S2 - FAIL (error)
    • ONOS devices doesn't match the list of allowed devices.
    • Expected devices: ['of:0000000000000001', 'of:0000000000000002']
    • Actual devices: []
  • 23.3 Check device annotations - PASS (tick)

Case 24: Testing removal of configurations - PASS

  • 24.1 Remove 'allowed' configuration from all devices - PASS (tick)
  • 24.2 Check net config - PASS (tick)
  • 24.3 Delete basic config for s1 and s2 - PASS (tick)
  • 24.4 Check net config - PASS (tick)
  • 24.5 Delete the net config for S3 - PASS (tick)
  • 24.6 Check net config - PASS (tick)
  • 24.7 Delete the net config for all devices - PASS (tick)
  • 24.8 Check net config - PASS (tick)
  • 24.9 Assert the net config for devices is empty - PASS (tick)