Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRBridging_onos-2.2_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit f198430fee8d188a8704f0cc06f403f10df70c3a 2d9ca233f0205c67d97feff7cff295d4108d7a1c (HEAD -] onos-2.2, origin/onos-2.2)
Author: Andrea Campanella [andrea@opennetworking.orgONOS Jenkins User [jenkins@onlab.us]
AuthorDate: Mon Fri Aug 10 1814 06:0609:42 35 2020 +02000000
Commit: Andrea Campanella [andrea@opennetworking.orgONOS Jenkins User [jenkins@onlab.us]
CommitDate: Wed Fri Aug 12 14 06:4709:09 35 2020 +0000
Ports and port description are not cleared up properly upon removal
Starting snapshot 2.2.5-SNAPSHOT

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, ovs switches and 3 ONOS instances - PASS

...

  • 8.1 Apply cell to environment - PASS (tick)
  • 8.2 Uninstalling Atomix - PASS (tick)
  • 8.3 Uninstalling ONOS package - PASS (tick)
  • 8.4 Installing Atomix - PASS (tick)
  • 8.5 Installing ONOS package - PASS (tick)
  • 8.6 Set up ONOS secure SSH - PASS (tick)
  • 8.7 Checking ONOS service - PASS (tick)
  • 8.8 Starting ONOS CLI sessions - PASS (tick)
  • 8.9 Checking ONOS nodes - PASS (tick)
  • 8.10 Checking ONOS applications - PASS (tick)
  • 8.11 Set logging levels - PASS (tick)
  • 8.12 Set ONOS configurations - PASS (tick)
  • 8.13 Starting Mininet Topology - PASS (tick)
  • 8.14 Check whether the flow count is bigger than 212 - PASS (tick)
  • 8.15 Check whether all flow status are ADDED - PASS (tick)
  • 8.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 8.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 8.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 8.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 8.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - PASS (tick)
  • 8.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - PASS (tick)
  • 8.22 Stopping Mininet - PASS (tick)
  • 8.23 Copying karaf logs - PASS (tick)

Case 15: Bridging test between two tagged hosts, with single ToR, ovs switches and 3 ONOS instances -

...

PASS

  • 15.1 Apply cell to environment - PASS (tick)
  • 15.2 Uninstalling Atomix - PASS (tick)
  • 15.3 Uninstalling ONOS package - PASS (tick)
  • 15.4 Installing Atomix - PASS (tick)
  • 15.5 Installing ONOS package - PASS (tick)
  • 15.6 Set up ONOS secure SSH - PASS (tick)
  • 15.7 Checking ONOS service - PASS (tick)
  • 15.8 Starting ONOS CLI sessions - PASS (tick)
  • 15.9 Checking ONOS nodes - PASS (tick)
  • 15.10 Checking ONOS applications - PASS (tick)
  • 15.11 Set logging levels - PASS (tick)
  • 15.12 Set ONOS configurations - PASS (tick)
  • 15.13 Starting Mininet Topology - PASS (tick)
  • 15.14 Check whether the flow count is bigger than 28 - FAIL (error)
    • Flow count looks wrong; found 18, expecting at least 28
  • PASS (tick)
  • 15.15 Check whether all flow status are ADDED - PASS (tick)
  • 15.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - FAIL (error)
    • Flow count looks wrong: 18
  • PASS (tick)
  • 15.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE15 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 15.18 Stopping Mininet - PASS (tick)
  • 15.19 Copying karaf logs - PASS (tick)

...

  • 36.1 Apply cell to environment - PASS (tick)
  • 36.2 Uninstalling Atomix - PASS (tick)
  • 36.3 Uninstalling ONOS package - PASS (tick)
  • 36.4 Installing Atomix - PASS (tick)
  • 36.5 Installing ONOS package - PASS (tick)
  • 36.6 Set up ONOS secure SSH - PASS (tick)
  • 36.7 Checking ONOS service - PASS (tick)
  • 36.8 Starting ONOS CLI sessions - PASS (tick)
  • 36.9 Checking ONOS nodes - PASS (tick)
  • 36.10 Checking ONOS applications - PASS (tick)
  • 36.11 Set logging levels - PASS (tick)
  • 36.12 Set ONOS configurations - PASS (tick)
  • 36.13 Starting Mininet Topology - PASS (tick)
  • 36.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 36.15 Check whether all flow status are ADDED - PASS (tick)
  • 36.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 36.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 36.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE36 - PASS (tick)
  • 36.19 Stopping Mininet - PASS (tick)
  • 36.20 Copying karaf logs - PASS (tick)

Case 37: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -

...

FAIL

  • 37.1 Apply cell to environment - PASS (tick)
  • 37.2 Uninstalling Atomix - PASS (tick)
  • 37.3 Uninstalling ONOS package - PASS (tick)
  • 37.4 Installing Atomix - PASS (tick)
  • 37.5 Installing ONOS package - PASS (tick)
  • 37.6 Set up ONOS secure SSH - PASS (tick)
  • 37.7 Checking ONOS service - PASS (tick)
  • 37.8 Starting ONOS CLI sessions - PASS (tick)
  • 37.9 Checking ONOS nodes - PASS (tick)
  • 37.10 Checking ONOS applications - PASS (tick)
  • 37.11 Set logging levels - PASS (tick)
  • 37.12 Set ONOS configurations - PASS (tick)
  • 37.13 Starting Mininet Topology - PASS (tick)
  • 37.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 37.15 Check whether all flow status are ADDED - PASS (tick)
  • 37.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 37.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 37.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 37.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - PASS (tick)
  • 37.20 Stopping Mininet - PASS (tick)
  • 37.21 Copying karaf logs - PASS (tick)

Case 38: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances -

...

PASS

  • 38.1 Apply cell to environment - PASS (tick)
  • 38.2 Uninstalling Atomix - PASS (tick)
  • 38.3 Uninstalling ONOS package - PASS (tick)
  • 38.4 Installing Atomix - PASS (tick)
  • 38.5 Installing ONOS package - PASS (tick)
  • 38.6 Set up ONOS secure SSH - PASS (tick)
  • 38.7 Checking ONOS service - PASS (tick)
  • 38.8 Starting ONOS CLI sessions - PASS (tick)
  • 38.9 Checking ONOS nodes - PASS (tick)
  • 38.10 Checking ONOS applications - PASS (tick)
  • 38.11 Set logging levels - PASS (tick)
  • 38.12 Set ONOS configurations - PASS (tick)
  • 38.13 Starting Mininet Topology - PASS (tick)
  • 38.14 Check whether the flow count is bigger than 212 - PASS (tick)
  • 38.15 Check whether all flow status are ADDED - PASS (tick)
  • 38.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 38.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 38.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 38.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 38.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE38 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 38.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE38 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 38.22 Stopping Mininet - PASS (tick)
  • 38.23 Copying karaf logs - PASS (tick)

...

  • 56.1 Apply cell to environment - PASS (tick)
  • 56.2 Uninstalling Atomix - PASS (tick)
  • 56.3 Uninstalling ONOS package - PASS (tick)
  • 56.4 Installing Atomix - PASS (tick)
  • 56.5 Installing ONOS package - PASS (tick)
  • 56.6 Set up ONOS secure SSH - PASS (tick)
  • 56.7 Checking ONOS service - PASS (tick)
  • 56.8 Starting ONOS CLI sessions - PASS (tick)
  • 56.9 Checking ONOS nodes - PASS (tick)
  • 56.10 Checking ONOS applications - PASS (tick)
  • 56.11 Set logging levels - PASS (tick)
  • 56.12 Set ONOS configurations - PASS (tick)
  • 56.13 Starting Mininet Topology - PASS (tick)
  • 56.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 56.15 Check whether all flow status are ADDED - PASS (tick)
  • 56.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 56.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 56.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE56 - PASS (tick)
  • 56.19 Stopping Mininet - PASS (tick)
  • 56.20 Copying karaf logs - PASS (tick)

Case 57: Bridging test between two untagged hosts with different vlan id, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -

...

PASS

  • 57.1 Apply cell to environment - PASS (tick)
  • 57.2 Uninstalling Atomix - PASS (tick)
  • 57.3 Uninstalling ONOS package - PASS (tick)
  • 57.4 Installing Atomix - PASS (tick)
  • 57.5 Installing ONOS package - PASS (tick)
  • 57.6 Set up ONOS secure SSH - PASS (tick)
  • 57.7 Checking ONOS service - PASS (tick)
  • 57.8 Starting ONOS CLI sessions - PASS (tick)
  • 57.9 Checking ONOS nodes - PASS (tick)
  • 57.10 Checking ONOS applications - PASS (tick)
  • 57.11 Set logging levels - PASS (tick)
  • 57.12 Set ONOS configurations - PASS (tick)
  • 57.13 Starting Mininet Topology - PASS (tick)
  • 57.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 57.15 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 57.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 57.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 57.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE57 - PASS (tick)
  • 57.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE57 - PASS (tick)
  • 57.20 Stopping Mininet - PASS (tick)
  • 57.21 Copying karaf logs - PASS (tick)

...