commit 9be7d21b933df37c8bae1767deb4c83040a12576 a93905c0c4e866441fe15c0fff93c774c3e35166 (HEAD -] onos-2.2, origin/onos-2.2)
Author: Charles Chan Andrea Campanella [charles@opennetworkingandrea@opennetworking.org]
AuthorDate: Fri Sep 4 19:50:57 2020 -0700Thu Jun 11 16:09:39 2020 +0200
Commit: Charles Chan Andrea Campanella [charles@opennetworkingandrea@opennetworking.org]
CommitDate: Tue Fri Sep 8 2318 14:0551:26 30 2020 +0000
Replace sed with perl0200

[VOL-3212] Modification to Trap flows:

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, ovs switches and 3 ONOS instances - PASS

...

  • 76.1 Apply cell to environment - PASS (tick)
  • 76.2 Uninstalling Atomix - PASS (tick)
  • 76.3 Uninstalling ONOS package - PASS (tick)
  • 76.4 Installing Atomix - PASS (tick)
  • 76.5 Installing ONOS package - PASS (tick)
  • 76.6 Set up ONOS secure SSH - PASS (tick)
  • 76.7 Checking ONOS service - PASS (tick)
  • 76.8 Starting ONOS CLI sessions - PASS (tick)
  • 76.9 Checking ONOS nodes - PASS (tick)
  • 76.10 Checking ONOS applications - PASS (tick)
  • 76.11 Set logging levels - PASS (tick)
  • 76.12 Set ONOS configurations - PASS (tick)
  • 76.13 Starting Mininet Topology - PASS (tick)
  • 76.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 76.15 Check whether all flow status are ADDED - PASS (tick)
  • 76.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 76.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 76.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE76 - PASS (tick)
  • 76.19 Stopping Mininet - PASS (tick)
  • 76.20 Copying karaf logs - PASS (tick)

Case 77: Bridging test between untagged and tagged hosts with different vlan id, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -

...

PASS

  • 77.1 Apply cell to environment - PASS (tick)
  • 77.2 Uninstalling Atomix - PASS (tick)
  • 77.3 Uninstalling ONOS package - PASS (tick)
  • 77.4 Installing Atomix - PASS (tick)
  • 77.5 Installing ONOS package - PASS (tick)
  • 77.6 Set up ONOS secure SSH - PASS (tick)
  • 77.7 Checking ONOS service - PASS (tick)
  • 77.8 Starting ONOS CLI sessions - PASS (tick)
  • 77.9 Checking ONOS nodes - PASS (tick)
  • 77.10 Checking ONOS applications - PASS (tick)
  • 77.11 Set logging levels - PASS (tick)
  • 77.12 Set ONOS configurations - PASS (tick)
  • 77.13 Starting Mininet Topology - PASS (tick)
  • 77.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 77.15 Check whether all flow status are ADDED - PASS (tick)
  • 77.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - FAIL (error)
  • Flow count looks wrong: 18
  • PASS (tick)
  • 77.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 77.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE77 - PASS (tick)
  • 77.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE77 - PASS (tick)
  • 77.20 Stopping Mininet - PASS (tick)
  • 77.21 Copying karaf logs - PASS (tick)

...