Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRLinkFailure-stratum_onos-2.2_20-builds_graph.jpg", alt="SRLinkFailure-stratum", style="width:525px;height:350px;border:0"> |
commit 897d92d094473847a1a843b72a2b9946ad902a6e f29d97b74268559eb6ab761e2cfd5c3b88782b0f (HEAD -] onos-2.2, origin/onos-2.2)
Author: Jian Li pierventre [pyguni@gmailpier@opennetworking.comorg]
AuthorDate: Sun Nov 15 01:02:59 2020 +0900Fri Jan 8 17:35:47 2021 +0100
Commit: Jian Li pierventre [pyguni@gmailpier@opennetworking.comorg]
CommitDate: Sun Nov 15 02:06:41 2020 +0900
Support Kubernetes LoadBalancer service typeFri Jan 22 18:35:16 2021 +0100
[AETHER-998] FabricPipeliner should support L2 modification of the NextObjective
Case 1: Bridging and Routing Link Failure test with 2x2 Leaf-spine and 1 Onos - PASS
...
- 1.1 Constructing test variables - PASS
- 1.2 Apply cell to environment - PASS
- 1.3 Uninstalling Atomix - PASS
- 1.4 Uninstalling ONOS package - PASS
- 1.5 Building ONOS Docker image - PASS
- 1.6 Create Cluster Config - PASS
- 1.7 Installing Atomix via docker containers - PASS
- 1.8 Installing ONOS via docker containers - PASS
- 1.9 Set up ONOS secure SSH - PASS
- 1.10 Starting ONOS CLI sessions - PASS
- 1.11 Checking ONOS nodes - PASS
- 1.12 Checking ONOS applications - PASS
- 1.13 Set logging levels - PASS
- 1.14 Set ONOS configurations - PASS
- 1.15 Starting Mininet Topology - PASS
- 1.16 Configure switches in ONOS - PASS
- 1.17 Check number of topology elements - PASS
- 1.18 Check whether the flow count is bigger than >= 116 - PASS
- 1.18 19 Check whether all flow status are ADDED - PASS
- 1.19 20 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - PASS
- 1.20 21 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS
- 1.21 22 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS
- 1.22 23 Kill link between spine101 and leaf2 - PASS
- 1.23 24 Checking topology after link down - PASS
- 1.24 25 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - PASS
- 1.25 26 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - PASS
- 1.26 27 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - PASS
- 1.27 28 Restore link between spine101 and leaf2 - PASS
- 1.29 Check whether the flow count is >= 116 - PASS
- 1.30 Check whether all flow status are ADDED - PASS
- 1.31 28 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Recovery - PASS
- 1.29 32 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Recovery - PASS
- 1.30 33 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Recovery - PASS
- 1.34 Check number of topology elements - PASS
- 1.35 31 Stopping Mininet - PASS
- 1.32 36 Copying karaf logs - PASS
...
- 2.1 Apply cell to environment - PASS
- 2.2 Uninstalling Atomix - PASS
- 2.3 Uninstalling ONOS package - PASS
- 2.4 Building ONOS Docker image - PASS
- 2.5 Create Cluster Config - PASS
- 2.6 Installing Atomix via docker containers - PASS
- 2.7 Installing ONOS via docker containers - PASS
- 2.8 Set up ONOS secure SSH - PASS
- 2.9 Starting ONOS CLI sessions - PASS
- 2.10 Checking ONOS nodes - PASS
- 2.11 Checking ONOS applications - PASS
- 2.12 Set logging levels - PASS
- 2.13 Set ONOS configurations - PASS
- 2.14 Starting Mininet Topology - PASS
- 2.15 Configure switches in ONOS - PASS
- 2.16 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 8 devices (8 expected) and 24 links (32 expected) and 1 controllers (1 expected) and 3 SCCs (1 expected)
- 2.17 Check whether the flow count is bigger than >= 350 - PASS
- 2.17 18 Check whether all flow status are ADDED - PASS
- 2.18 19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - PASS FAIL
- IP connectivity failed
- 2.19 20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS
- 2.20 21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS
- 2.21 22 Kill link between spine101 and leaf2 - PASS
- 2.22 23 Checking topology after link down - FAIL
- Topology after link down is incorrect
- 2.23 24 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - PASS FAIL
- IP connectivity failed
- 2.24 25 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - PASS
- 2.25 26 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - PASS
- 2.26 27 Restore link between spine101 and leaf2 - FAIL
- Failed to bring link up
- 2.28 Check whether the flow count is >= 350 - PASS
- 2.29 Check whether all flow status are ADDED - PASS
- 2.27 30 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Recovery - PASS FAIL
- IP connectivity failed
- 2.28 31 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Recovery - PASS
- 2.29 32 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Recovery - PASS
- 2.33 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 8 devices (8 expected) and 24 links (32 expected) and 1 controllers (1 expected) and 3 SCCs (1 expected)
- 2.30 34 Stopping Mininet - PASS
- 2.31 35 Copying karaf logs - PASS
Case 4: Bridging and Routing Link Failure test with 2x2 Leaf-spine and 3 Onos -
...
FAIL
- 4.1 Apply cell to environment - PASS
- 4.2 Uninstalling Atomix - PASS
- 4.3 Uninstalling ONOS package - PASS
- 4.4 Building ONOS Docker image - PASS
- 4.5 Create Cluster Config - PASS
- 4.6 Installing Atomix via docker containers - PASS
- 4.7 Installing ONOS via docker containers - PASS
- 4.8 Set up ONOS secure SSH - PASS
- 4.9 Starting ONOS CLI sessions - PASS
- 4.10 Checking ONOS nodes - PASS
- 4.11 Checking ONOS applications - PASS
- 4.12 Set logging levels - PASS
- 4.13 Set ONOS configurations - PASS
- 4.14 Starting Mininet Topology - PASS
- 4.15 Configure switches in ONOS - PASS
- 4.16 Check number of topology elements - PASS
- 4.17 Check whether the flow count is bigger than >= 116 - PASS
- 4.17 18 Check whether all flow status are ADDED - PASS
- 4.18 19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4 - PASS CASE3 - FAIL
- IP connectivity failed
- 4.19 20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4 CASE3 - PASS
- 4.20 21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4 CASE3 - PASS
- 4.21 22 Kill link between spine101 and leaf2 - PASS
- 4.22 23 Checking topology after link down - PASS
- 4.23 24 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE3_Failure - PASS FAIL
- IP connectivity failed
- 4.24 25 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Failure - PASS
- 4.25 26 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Failure - PASS
- 4.26 27 Restore link between spine101 and leaf2 - PASS
- 4.28 Check whether the flow count is >= 116 - PASS
- 4.29 Check whether all flow status are ADDED - PASS
- 4.30 27 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE3_Recovery - PASS FAIL
- IP connectivity failed
- 4.28 31 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Recovery - PASS
- 4.29 32 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Recovery - PASS
- 4.33 Check number of topology elements - PASS
- 4.34 30 Stopping Mininet - PASS
- 4.31 35 Copying karaf logs - PASS
...
- 5.1 Apply cell to environment - PASS
- 5.2 Uninstalling Atomix - PASS
- 5.3 Uninstalling ONOS package - PASS
- 5.4 Building ONOS Docker image - PASS
- 5.5 Create Cluster Config - PASS
- 5.6 Installing Atomix via docker containers - PASS
- 5.7 Installing ONOS via docker containers - PASS
- 5.8 Set up ONOS secure SSH - PASS
- 5.9 Starting ONOS CLI sessions - PASS
- 5.10 Checking ONOS nodes - PASS
- 5.11 Checking ONOS applications - PASS
- 5.12 Set logging levels - PASS
- 5.13 Set ONOS configurations - PASS
- 5.14 Starting Mininet Topology - PASS
- 5.15 Configure switches in ONOS - PASS
- 5.16 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 8 devices (8 expected) and 8 links (32 expected) and 3 controllers (3 expected) and 8 SCCs (1 expected)
- 5.17 Check whether the flow count is bigger than >= 350 - PASS
- 5.17 18 Check whether all flow status are ADDED - PASS
- 5.18 19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5 CASE4 - FAIL
- IP connectivity failed
- 5.19 20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5 CASE4 - PASS
- 5.20 21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5 CASE4 - PASS
- 5.21 22 Kill link between spine101 and leaf2 - PASS
- 5.22 23 Checking topology after link down - FAIL
- Topology after link down is incorrect
- 5.23 24 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE4_Failure - FAIL
- IP connectivity failed
- 5.24 25 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_Failure - PASS
- 5.25 26 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_Failure - PASS
- 5.26 27 Restore link between spine101 and leaf2 - FAIL
- Failed to bring link up
- 5.28 Check whether the flow count is >= 350 - PASS
- 5.29 Check whether all flow status are ADDED - PASS
- 5.30 27 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE4_Recovery - FAIL
- IP connectivity failed
- 5.28 31 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_Recovery - PASS
- 5.29 32 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_Recovery - PASS
- 5.33 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 8 devices (8 expected) and 8 links (32 expected) and 3 controllers (3 expected) and 8 SCCs (1 expected)
- 5.34 30 Stopping Mininet - PASS
- 5.31 35 Copying karaf logs - PASS