Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

  • 13.1 Constructing test variables - PASS (tick)
  • 13.2 Apply cell to environment - PASS (tick)
  • 13.3 Uninstalling Atomix - PASS (tick)
  • 13.4 Uninstalling ONOS package - PASS (tick)
  • 13.5 Building ONOS Docker image - PASS (tick)
  • 13.6 Create Cluster Config - PASS (tick)
  • 13.7 Installing Atomix via docker containers - PASS (tick)
  • 13.8 Installing ONOS via docker containers - PASS (tick)
  • 13.9 Set up ONOS secure SSH - PASS (tick)
  • 13.10 Starting ONOS CLI sessions - PASS (tick)
  • 13.11 Checking ONOS nodes - PASS (tick)
  • 13.12 Checking ONOS applications - PASS (tick)
  • 13.13 Set logging levels - PASS (tick)
  • 13.14 Set ONOS configurations - PASS (tick)
  • 13.15 Starting Mininet Topology - PASS (tick)
  • 13.16 Configure switches in ONOS - PASS (tick)
  • 13.17 Check whether the flow count is >= 104 - FAIL (error)
    • Flow count looks wrong; found 0, expecting at least 104
  • 13.18 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 13.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - PASS (tick)
  • 13.20 Check whether the flow count of device device:bmv2:leaf1 >= than 52 - FAIL (error)
    • Flow count looks wrong: 0
  • 13.21 Check whether the flow count of device device:bmv2:leaf2 >= than 52 - FAIL (error)
    • Flow count looks wrong: 0
  • 13.22 Check whether the flow count is >= 104 - FAIL (error)
    • Flow count looks wrong; found 0, expecting at least 104
  • 13.23 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 13.24 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - PASS (tick)
  • 13.25 Stopping Mininet - PASS (tick)
  • 13.26 Copying karaf logs - PASS (tick)

Case 23: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

  • 23.1 Apply cell to environment - PASS (tick)
  • 23.2 Uninstalling Atomix - PASS (tick)
  • 23.3 Uninstalling ONOS package - PASS (tick)
  • 23.4 Create Cluster Config - PASS (tick)
  • 23.5 Installing Atomix via docker containers - PASS (tick)
  • 23.6 Installing ONOS via docker containers - PASS (tick)
  • 23.7 Set up ONOS secure SSH - PASS (tick)
  • 23.8 Starting ONOS CLI sessions - PASS (tick)
  • 23.9 Checking ONOS nodes - PASS (tick)
  • 23.10 Checking ONOS applications - PASS (tick)
  • 23.11 Set logging levels - PASS (tick)
  • 23.12 Set ONOS configurations - PASS (tick)
  • 23.13 Starting Mininet Topology - PASS (tick)
  • 23.14 Configure switches in ONOS - PASS (tick)
  • 23.15 Check whether the flow count is >= 106 - FAIL (error)
    • Flow count looks wrong; found 0, expecting at least 106
  • 23.16 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 23.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS (tick)
  • 23.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS (tick)
  • 23.19 Check whether the flow count of device device:bmv2:leaf1 >= than 53 - FAIL (error)
    • Flow count looks wrong: 0
  • 23.20 Check whether the flow count of device device:bmv2:leaf2 >= than 53 - FAIL (error)
    • Flow count looks wrong: 0
  • 23.21 Check whether the flow count is >= 106 - FAIL (error)
    • Flow count looks wrong; found 0, expecting at least 106
  • 23.22 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 23.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS (tick)
  • 23.24 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS (tick)
  • 23.25 Stopping Mininet - PASS (tick)
  • 23.26 Copying karaf logs - PASS (tick)