Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
- 23.1 Apply cell to environment - PASS
- 23.2 Uninstalling Atomix - PASS
- 23.3 Uninstalling ONOS package - PASS
- 23.4 Installing Atomix - PASS
- 23.5 Installing ONOS package - PASS
- 23.6 Set up ONOS secure SSH - PASS
- 23.7 Checking ONOS service - PASS
- 23.8 Starting ONOS CLI sessions - PASS
- 23.9 Checking ONOS nodes - PASS
- 23.10 Checking ONOS applications - PASS
- 23.11 Starting Mininet Topology - PASS
- 23.12 Check whether the flow count is bigger than 106 - PASS
- 23.13 Check whether all flow status are ADDED - PASS
- 23.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS
- 23.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS
- 23.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 23.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 23.18 Check whether the flow count is bigger than 106 - PASS
- 23.19 Check whether all flow status are ADDED - PASS
- 23.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS
- 23.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS
- 23.22 Stopping Mininet - PASS
- 23.23 Copying karaf logs - PASS
Case 33: Changing port configuration from untagged 10 to untagged 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 33.1 Apply cell to environment - PASS
- 33.2 Uninstalling Atomix - PASS
- 33.3 Uninstalling ONOS package - PASS
- 33.4 Installing Atomix - PASS
- 33.5 Installing ONOS package - PASS
- 33.6 Set up ONOS secure SSH - PASS
- 33.7 Checking ONOS service - PASS
- 33.8 Starting ONOS CLI sessions - PASS
- 33.9 Checking ONOS nodes - PASS
- 33.10 Checking ONOS applications - PASS
- 33.11 Starting Mininet Topology - PASS
- 33.12 Check whether the flow count is bigger than 104 - PASS
- 33.13 Check whether all flow status are ADDED - PASS
- 33.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - PASS
- 33.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - PASS
- 33.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 33.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 33.18 Check whether the flow count is bigger than 104 - PASS
- 33.19 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- PASS
- 33.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - PASS
- 33.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS
- 33.22 Stopping Mininet - PASS
- 33.23 Copying karaf logs - PASS
...
- 53.1 Apply cell to environment - PASS
- 53.2 Uninstalling Atomix - PASS
- 53.3 Uninstalling ONOS package - PASS
- 53.4 Installing Atomix - PASS
- 53.5 Installing ONOS package - PASS
- 53.6 Set up ONOS secure SSH - PASS
- 53.7 Checking ONOS service - PASS
- 53.8 Starting ONOS CLI sessions - PASS
- 53.9 Checking ONOS nodes - PASS
- 53.10 Checking ONOS applications - PASS
- 53.11 Starting Mininet Topology - PASS
- 53.12 Check whether the flow count is bigger than 104 - PASS
- 53.13 Check whether all flow status are ADDED - PASS
- 53.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_Before - PASS
- 53.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_Before - PASS
- 53.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 53.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 53.18 Check whether the flow count is bigger than 104 - PASS
- 53.19 Check whether all flow status are ADDED - PASS
- 53.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_After - PASS
- 53.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_After - PASS
- 53.22 Stopping Mininet - PASS
- 53.23 Copying karaf logs - PASS
Case 63: Changing port configuration from untagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 63.1 Apply cell to environment - PASS
- 63.2 Uninstalling Atomix - PASS
- 63.3 Uninstalling ONOS package - PASS
- 63.4 Installing Atomix - PASS
- 63.5 Installing ONOS package - PASS
- 63.6 Set up ONOS secure SSH - PASS
- 63.7 Checking ONOS service - PASS
- 63.8 Starting ONOS CLI sessions - PASS
- 63.9 Checking ONOS nodes - PASS
- 63.10 Checking ONOS applications - PASS
- 63.11 Starting Mininet Topology - PASS
- 63.12 Check whether the flow count is bigger than 104 - PASS
- 63.13 Check whether all flow status are ADDED - PASS
- 63.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS
- 63.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS
- 63.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 63.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 63.18 Check whether the flow count is bigger than 104 - PASS
- 63.19 Check whether all flow status are ADDED - FAIL Flow status is wrong!
- PASS
- 63.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS
- 63.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS
- 63.22 Stopping Mininet - PASS
- 63.23 Copying karaf logs - PASS
...
- 103.1 Apply cell to environment - PASS
- 103.2 Uninstalling Atomix - PASS
- 103.3 Uninstalling ONOS package - PASS
- 103.4 Installing Atomix - PASS
- 103.5 Installing ONOS package - PASS
- 103.6 Set up ONOS secure SSH - PASS
- 103.7 Checking ONOS service - PASS
- 103.8 Starting ONOS CLI sessions - PASS
- 103.9 Checking ONOS nodes - PASS
- 103.10 Checking ONOS applications - PASS
- 103.11 Starting Mininet Topology - PASS
- 103.12 Check whether the flow count is bigger than 104 - PASS
- 103.13 Check whether all flow status are ADDED - PASS
- 103.14 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_Before - PASS
- 103.15 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 103.16 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 103.17 Check whether the flow count is bigger than 104 - PASS
- 103.18 Check whether all flow status are ADDED - PASS
- 103.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_After - PASS
- 103.20 Stopping Mininet - PASS
- 103.21 Copying karaf logs - PASS
Case 113: Changing port configuration from tagged 20 and native 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 113.1 Apply cell to environment - PASS
- 113.2 Uninstalling Atomix - PASS
- 113.3 Uninstalling ONOS package - PASS
- 113.4 Installing Atomix - PASS
- 113.5 Installing ONOS package - PASS
- 113.6 Set up ONOS secure SSH - PASS
- 113.7 Checking ONOS service - PASS
- 113.8 Starting ONOS CLI sessions - PASS
- 113.9 Checking ONOS nodes - PASS
- 113.10 Checking ONOS applications - PASS
- 113.11 Starting Mininet Topology - PASS
- 113.12 Check whether the flow count is bigger than 104 - PASS
- 113.13 Check whether all flow status are ADDED - PASS
- 113.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - PASS
- 113.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - PASS
- 113.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 113.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 113.18 Check whether the flow count is bigger than 104 - PASS
- 113.19 Check whether all flow status are ADDED - FAIL Flow status is wrong!
- PASS
- 113.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - PASS
- 113.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS
- 113.22 Stopping Mininet - PASS
- 113.23 Copying karaf logs - PASS
...
- 163.1 Apply cell to environment - PASS
- 163.2 Uninstalling Atomix - PASS
- 163.3 Uninstalling ONOS package - PASS
- 163.4 Installing Atomix - PASS
- 163.5 Installing ONOS package - PASS
- 163.6 Set up ONOS secure SSH - FAIL Failed to secure ssh
- PASS
- 163.7 Checking ONOS service - PASS
- 163.8 Starting ONOS CLI sessions - PASS
- 163.9 Checking ONOS nodes - PASS
- 163.10 Checking ONOS applications - PASS
- 163.11 Starting Mininet Topology - PASS
- 163.12 Check whether the flow count is bigger than 106 - PASS
- 163.13 Check whether all flow status are ADDED - PASS
- 163.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE163_Before - PASS FAIL
- IP connectivity failed
- 163.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_Before - PASS
- 163.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 163.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 163.18 Check whether the flow count is bigger than 106 - PASS
- 163.19 Check whether all flow status are ADDED - PASS
- 163.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE163_After - PASS FAIL
- IP connectivity failed
- 163.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_After - PASS
- 163.22 Stopping Mininet - PASS
- 163.23 Copying karaf logs - PASS
...
- 193.1 Apply cell to environment - PASS
- 193.2 Uninstalling Atomix - PASS
- 193.3 Uninstalling ONOS package - PASS
- 193.4 Installing Atomix - PASS
- 193.5 Installing ONOS package - PASS
- 193.6 Set up ONOS secure SSH - PASS
- 193.7 Checking ONOS service - PASS
- 193.8 Starting ONOS CLI sessions - PASS
- 193.9 Checking ONOS nodes - PASS
- 193.10 Checking ONOS applications - PASS
- 193.11 Starting Mininet Topology - PASS
- 193.12 Check whether the flow count is bigger than 106 - PASS
- 193.13 Check whether all flow status are ADDED - PASS
- 193.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE193_Before - PASS
- 193.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE193_Before - PASS
- 193.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 193.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 193.18 Check whether the flow count is bigger than 106 - PASS
- 193.19 Check whether all flow status are ADDED - PASS
- 193.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE193_After - PASS
- 193.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE193_After - PASS
- 193.22 Stopping Mininet - PASS
- 193.23 Copying karaf logs - PASS
Case 203: Changing port configuration from tagged 20 and native 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -
...
- 203.1 Apply cell to environment - PASS
- 203.2 Uninstalling Atomix - PASS
- 203.3 Uninstalling ONOS package - PASS
- 203.4 Installing Atomix - PASS
- 203.5 Installing ONOS package - PASS
- 203.6 Set up ONOS secure SSH - PASS
- 203.7 Checking ONOS service - PASS
- 203.8 Starting ONOS CLI sessions - PASS
- 203.9 Checking ONOS nodes - PASS
- 203.10 Checking ONOS applications - PASS
- 203.11 Starting Mininet Topology - PASS
- 203.12 Check whether the flow count is bigger than 106 - PASS
- 203.13 Check whether all flow status are ADDED - PASS
- 203.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_Before - PASS
- 203.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_Before - PASS
- 203.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 203.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 203.18 Check whether the flow count is bigger than 106 - PASS
- 203.19 Check whether all flow status are ADDED - PASS
- 203.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_After - PASS
- 203.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_After - PASS
- 203.22 Stopping Mininet - PASS
- 203.23 Copying karaf logs - PASS
Case 213: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances - PASS
- 213.1 Apply cell to environment - PASS
- 213.2 Uninstalling Atomix - PASS
- 213.3 Uninstalling ONOS package - PASS
- 213.4 Installing Atomix - PASS
- 213.5 Installing ONOS package - PASS
- 213.6 Set up ONOS secure SSH - PASS
- 213.7 Checking ONOS service - PASS
- 213.8 Starting ONOS CLI sessions - PASS
- 213.9 Checking ONOS nodes - PASS
- 213.10 Checking ONOS applications - PASS
- 213.11 Starting Mininet Topology - PASS
- 213.12 Check whether the flow count is bigger than 106 - PASS
- 213.13 Check whether all flow status are ADDED - PASS
- 213.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_Before - PASS
- 213.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_Before - PASS
- 213.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 213.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 213.18 Check whether the flow count is bigger than 106 - PASS
- 213.19 Check whether all flow status are ADDED - PASS
- 213.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_After - PASS
- 213.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_After - PASS
- 213.22 Stopping Mininet - PASS
- 213.23 Copying karaf logs - PASS
Case 223: Changing port configuration from tagged 20 and native 10 to tagged 120 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL
- 223.1 Apply cell to environment - PASS
- 223.2 Uninstalling Atomix - PASS
- 223.3 Uninstalling ONOS package - PASS
- 223.4 Installing Atomix - PASS
- 223.5 Installing ONOS package - PASS
- 223.6 Set up ONOS secure SSH - PASS
- 223.7 Checking ONOS service - PASS
- 223.8 Starting ONOS CLI sessions - PASS
- 223.9 Checking ONOS nodes - PASS
- 223.10 Checking ONOS applications - PASS
- 223.11 Starting Mininet Topology - PASS
- 223.12 Check whether the flow count is bigger than 106 - FAIL
- Flow count looks wrong: 98
- 223.13 Check whether all flow status are ADDED - PASS
- 223.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE223_Before - FAIL
- IP connectivity failed
- 223.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE223_Before - PASS
- 223.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL
- Flow count looks wrong: 18
- 223.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL
- Flow count looks wrong: 18
- 223.18 Check whether the flow count is bigger than 106 - FAIL
- Flow count looks wrong: 104
- 223.19 Check whether all flow status are ADDED - PASS
- 223.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE223_After - FAIL
- IP connectivity failed
- 223.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE223_After - PASS
- 223.22 Stopping Mininet - PASS
- 223.23 Copying karaf logs - PASS
Case 233: Consecutive configuration changes, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL
- 233.1 Apply cell to environment - PASS
- 233.2 Uninstalling Atomix - PASS
- 233.3 Uninstalling ONOS package - PASS
- 233.4 Installing Atomix - PASS
- 233.5 Installing ONOS package - PASS
- 233.6 Set up ONOS secure SSH - PASS
- 233.7 Checking ONOS service - PASS
- 233.8 Starting ONOS CLI sessions - PASS
- 233.9 Checking ONOS nodes - PASS
- 233.10 Checking ONOS applications - PASS
- 233.11 Starting Mininet Topology - PASS
- 233.12 Check whether the flow count is bigger than 104 - PASS
- 233.13 Check whether all flow status are ADDED - PASS
- 233.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_Before - PASS
- 233.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_Before - PASS
- 233.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 233.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 233.18 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 233.19 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 233.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_1 - PASS
- 233.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_1 - PASS
- 233.22 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 233.23 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 233.24 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_2 - PASS
- 233.25 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_2 - PASS
- 233.26 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 233.27 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 233.28 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_3 - PASS
- 233.29 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_3 - PASS
- 233.30 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 233.31 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 233.32 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_4 - PASS
- 233.33 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_4 - FAIL
- IP connectivity failed
- 233.34 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 233.35 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 233.36 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_5 - PASS
- 233.37 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_5 - PASS
- 233.38 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 233.39 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 233.40 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_6 - PASS
- 233.41 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_6 - PASS
- 233.42 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 233.43 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 233.44 Check whether the flow count is bigger than 104 - PASS
- 233.45 Check whether all flow status are ADDED - PASS
- 233.46 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_After - PASS
- 233.47 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_After - PASS
- 233.48 Stopping Mininet - PASS
- 233.49 Copying karaf logs - PASS
Case 243: Changing port configuration from 10.0.2.254/24 to 10.0.6.254/24, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL
...
- IP connectivity failed
...
- IP connectivity failed
...