Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRSwitchFailure_onos-2.2_20-builds_graph.jpg", alt="SRSwitchFailure", style="width:525px;height:350px;border:0">

commit 3bc3d5b746cf58b5ab192cb6d7f175ab6966e79d 8ee219fd7ea1e230c497ff00943c7c4007f2a827 (HEAD -] onos-2.2, origin/onos-2.2)
Author: Jian Li pierventre [pyguni@gmailpier@opennetworking.comorg]
AuthorDate: Wed Tue Sep 23 1615 12:4644:12 52 2020 +09000200
Commit: Jian Li [pyguni@gmail.comPier Luigi Ventre [pier@opennetworking.org]
CommitDate: Wed Sep 23 08:38:27 Fri Oct 2 10:21:52 2020 +0000
Use port's MacAddress to associate ONOS port and Kubernetes port
[AETHER-38] Moves T3 utils to ONOS utils

Case 1: Switch Failure test with 2x2 Leaf-spine and 1 Onos - FAIL

...

  • 5.1 Apply cell to environment - PASS (tick)
  • 5.2 Uninstalling Atomix - PASS (tick)
  • 5.3 Uninstalling ONOS package - PASS (tick)
  • 5.4 Creating ONOS package - PASS (tick)
  • 5.5 Installing Atomix - PASS (tick)
  • 5.6 Installing ONOS package - PASS (tick)
  • 5.7 Set up ONOS secure SSH - PASS (tick)
  • 5.8 Checking ONOS service - PASS (tick)
  • 5.9 Starting ONOS CLI sessions - PASS (tick)
  • 5.10 Checking ONOS nodes - PASS (tick)
  • 5.11 Checking ONOS applications - PASS (tick)
  • 5.12 Set logging levels - PASS (tick)
  • 5.13 Set ONOS configurations - PASS (tick)
  • 5.14 Starting Mininet Topology - PASS (tick)
  • 5.15 Check whether the flow count is bigger than 350 - PASS (tick)
  • 5.16 Check whether all flow status are ADDED - PASS (tick)
  • 5.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 5.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.20 Kill ['spine101'] - PASS (tick)
  • 5.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5_Failure - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 5.22 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5_Failure - FAIL (error)
    • IP connectivity failed
  • 5.23 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5_Failure - FAIL (error)
    • IP connectivity failed
  • 5.24 Recovering ['spine101'] - PASS (tick)
  • 5.25 Check whether the flow count is bigger than 350 - PASS (tick)
  • 5.26 Check whether all flow status are ADDED - PASS (tick)
  • 5.27 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5_Recovery - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 5.28 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5_Recovery - FAIL (error)
    • IP connectivity failed
  • 5.29 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5_Recovery - FAIL (error)
    • IP connectivity failed
  • 5.30 Stopping Mininet - PASS (tick)
  • 5.31 Copying karaf logs - PASS (tick)