Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRDynamicConf-stratum_master_20-builds_graph.jpg", alt="SRDynamicConf-stratum", style="width:525px;height:350px;border:0">

commit 7850330bef3a08e7ae17cf74a9c899eb2468182a dd54d5657f40fbd9b2835f9776bedcaf51ff89e9 (HEAD -] master, origin/master, origin/HEAD)
Author: Yi Tseng Andrea Campanella [yi@opennetworkingandrea@opennetworking.org]
AuthorDate: Mon Wed Oct 5 237 16:5344:54 21 2020 -0700+0200
Commit: Yi Tseng Andrea Campanella [yi@opennetworkingandrea@opennetworking.org]
CommitDate: Wed Fri Oct 7 189 07:0155:51 37 2020 +0000
Display decimal value in the INT UI instead of hex
[ONOS-8121][VOL-3259] Fixing null filter for felix fileinstall
--
(cherry picked from commit 56717459b1985dafc73ecaae4c315287fab51996cf3284174edba18f921995fe01fb0e5f802caf7e)

Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

...

  • 73.1 Apply cell to environment - PASS (tick)
  • 73.2 Uninstalling Atomix - PASS (tick)
  • 73.3 Uninstalling ONOS package - PASS (tick)
  • 73.4 Create Cluster Config - PASS (tick)
  • 73.5 Installing Atomix via docker containers - PASS (tick)
  • 73.6 Installing ONOS via docker containers - PASS (tick)
  • 73.7 Set up ONOS secure SSH - PASS (tick)
  • 73.8 Starting ONOS CLI sessions - PASS (tick)
  • 73.9 Checking ONOS nodes - PASS (tick)
  • 73.10 Checking ONOS applications - PASS (tick)
  • 73.11 Set logging levels - PASS (tick)
  • 73.12 Set ONOS configurations - PASS (tick)
  • 73.13 Starting Mininet Topology - PASS (tick)
  • 73.14 Configure switches in ONOS - PASS (tick)
  • 73.15 Check whether the flow count is bigger than 106 - PASS (tick)
  • 73.16 Check whether all flow status are ADDED - PASS (tick)
  • 73.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE73_Before - PASS (tick)
  • 73.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE73_Before - PASS (tick)
  • 73.19 Check whether the flow count of device device:bmv2:leaf1 is bigger than 53 - PASS (tick)
  • 73.20 Check whether the flow count of device device:bmv2:leaf2 is bigger than 53 - PASS (tick)
  • 73.21 Check whether the flow count is bigger than 106 - PASS (tick)
  • 73.22 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 73.23 Verify full connectivity for [u'h3', u'h4'] with tag CASE73_After - PASS (tick)
  • 73.24 Verify full connectivity for [u'h1', u'h2'] with tag CASE73_After - FAIL (error)
    • IP connectivity failed
  • 73.25 Stopping Mininet - PASS (tick)
  • 73.26 Copying karaf logs - PASS (tick)

...

  • 223.1 Apply cell to environment - PASS (tick)
  • 223.2 Uninstalling Atomix - PASS (tick)
  • 223.3 Uninstalling ONOS package - PASS (tick)
  • 223.4 Create Cluster Config - PASS (tick)
  • 223.5 Installing Atomix via docker containers - PASS (tick)
  • 223.6 Installing ONOS via docker containers - PASS (tick)
  • 223.7 Set up ONOS secure SSH - PASS (tick)
  • 223.8 Starting ONOS CLI sessions - PASS (tick)
  • 223.9 Checking ONOS nodes - PASS (tick)
  • 223.10 Checking ONOS applications - PASS (tick)
  • 223.11 Set logging levels - PASS (tick)
  • 223.12 Set ONOS configurations - PASS (tick)
  • 223.13 Starting Mininet Topology - PASS (tick)
  • 223.14 Configure switches in ONOS - PASS (tick)
  • 223.15 Check whether the flow count is bigger than 106 - PASS (tick)
  • 223.16 Check whether all flow status are ADDED - PASS (tick)
  • 223.17 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE223_Before - PASS (tick)
  • 223.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE223_Before - PASS (tick)
  • 223.19 Check whether the flow count of device device:bmv2:leaf1 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 53
  • 223.20 Check whether the flow count of device device:bmv2:leaf2 is bigger than 53 - PASS (tick)
  • 223.21 Check whether the flow count is bigger than 106 - PASS (tick)
  • 223.22 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 223.23 Verify full connectivity for [u'h3', u'h4'] with tag CASE223_After - PASS (tick)
  • 223.24 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE223_After - PASS (tick)
  • 223.25 Stopping Mininet - PASS (tick)
  • 223.26 Copying karaf logs - PASS (tick)

...