commit dd54d5657f40fbd9b2835f9776bedcaf51ff89e9 a5212170cc0944e5d8af5e4d6d801217fec35431 (HEAD -] master, origin/master, origin/HEAD)
Author: Andrea Campanella Jian Li [andrea@opennetworkingpyguni@gmail.orgcom]
AuthorDate: Wed Mon Oct 7 1612 02:4407:21 30 2020 +02000900
Commit: Andrea Campanella Jian Li [andrea@opennetworkingpyguni@gmail.orgcom]
CommitDate: Fri Sun Oct 9 0711 18:5544:37 07 2020 +0000
[ONOS-8121][VOL-3259] Fixing null filter for felix fileinstall
Support SNATing POD traffic to internet at k8s passthrough mode
--
(cherry picked from commit cf3284174edba18f921995fe01fb0e5f802caf7e2622d5a002e7eba4c00271885845be787866358a)
Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL
...
- 63.1 Apply cell to environment - PASS
- 63.2 Uninstalling Atomix - PASS
- 63.3 Uninstalling ONOS package - PASS
- 63.4 Create Cluster Config - PASS
- 63.5 Installing Atomix via docker containers - PASS
- 63.6 Installing ONOS via docker containers - PASS
- 63.7 Set up ONOS secure SSH - PASS
- 63.8 Starting ONOS CLI sessions - PASS
- 63.9 Checking ONOS nodes - PASS
- 63.10 Checking ONOS applications - PASS
- 63.11 Set logging levels - PASS
- 63.12 Set ONOS configurations - PASS
- 63.13 Starting Mininet Topology - PASS
- 63.14 Configure switches in ONOS - PASS
- 63.15 Check whether the flow count is bigger than 104 - PASS
- 63.16 Check whether all flow status are ADDED - PASS
- 63.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS
- 63.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS
- 63.19 Check whether the flow count of device device:bmv2:leaf1 is bigger than 52 - PASS
- 63.20 Check whether the flow count of device device:bmv2:leaf2 is bigger than 52 - PASS
- 63.21 Check whether the flow count is bigger than 104 - PASS
- 63.22 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 63.23 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS
- 63.24 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS FAIL
- IP connectivity failed
- 63.25 Stopping Mininet - PASS
- 63.26 Copying karaf logs - PASS
...
- 223.1 Apply cell to environment - PASS
- 223.2 Uninstalling Atomix - PASS
- 223.3 Uninstalling ONOS package - PASS
- 223.4 Create Cluster Config - PASS
- 223.5 Installing Atomix via docker containers - PASS
- 223.6 Installing ONOS via docker containers - PASS
- 223.7 Set up ONOS secure SSH - PASS
- 223.8 Starting ONOS CLI sessions - PASS
- 223.9 Checking ONOS nodes - PASS
- 223.10 Checking ONOS applications - PASS
- 223.11 Set logging levels - PASS
- 223.12 Set ONOS configurations - PASS
- 223.13 Starting Mininet Topology - PASS
- 223.14 Configure switches in ONOS - PASS
- 223.15 Check whether the flow count is bigger than 106 - PASS
- 223.16 Check whether all flow status are ADDED - PASS
- 223.17 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE223_Before - PASS
- 223.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE223_Before - PASS
- 223.19 Check whether the flow count of device device:bmv2:leaf1 is bigger than 53 - FAIL Flow count looks wrong: 53
- PASS
- 223.20 Check whether the flow count of device device:bmv2:leaf2 is bigger than 53 - PASS
- 223.21 Check whether the flow count is bigger than 106 - PASS
- 223.22 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 223.23 Verify full connectivity for [u'h3', u'h4'] with tag CASE223_After - PASS
- 223.24 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE223_After - PASS
- 223.25 Stopping Mininet - PASS
- 223.26 Copying karaf logs - PASS
...