- 7.1 Apply cell to environment - PASS
- 7.2 Uninstalling Atomix - PASS
- 7.3 Uninstalling ONOS package - PASS
- 7.4 Create Cluster Config - PASS
- 7.5 Installing Atomix via docker containers - PASS
- 7.6 Installing ONOS via docker containers - PASS
- 7.7 Set up ONOS secure SSH - PASS
- 7.8 Starting ONOS CLI sessions - PASS
- 7.9 Checking ONOS nodes - PASS
- 7.10 Checking ONOS applications - PASS
- 7.11 Set logging levels - PASS
- 7.12 Set ONOS configurations - PASS
- 7.13 Starting Mininet Topology - PASS
- 7.14 Configure switches in ONOS - PASS
- 7.15 Check whether the flow count is bigger than 64 - PASS
- 7.16 Check whether all flow status are ADDED - PASS
- 7.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 32 - PASS
- 7.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 32 - PASS
- 7.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS
- 7.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS
- 7.21 Stopping Mininet - PASS
- 7.22 Copying karaf logs - PASS
Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology, stratum switches and 3 ONOS instances -
...
- 8.1 Apply cell to environment - PASS
- 8.2 Uninstalling Atomix - PASS
- 8.3 Uninstalling ONOS package - PASS
- 8.4 Create Cluster Config - PASS
- 8.5 Installing Atomix via docker containers - PASS
- 8.6 Installing ONOS via docker containers - PASS
- 8.7 Set up ONOS secure SSH - PASS
- 8.8 Starting ONOS CLI sessions - PASS
- 8.9 Checking ONOS nodes - PASS
- 8.10 Checking ONOS applications - PASS
- 8.11 Set logging levels - PASS
- 8.12 Set ONOS configurations - PASS
- 8.13 Starting Mininet Topology - PASS
- 8.14 Configure switches in ONOS - PASS
- 8.15 Check whether the flow count is bigger than 212 - PASS
- 8.16 Check whether all flow status are ADDED - PASS
- 8.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 53 - PASS
- 8.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 53 - PASS
- 8.19 Check whether the flow count of device device:bmv2:leaf3 is bigger than 53 - PASS
- 8.20 Check whether the flow count of device device:bmv2:leaf4 is bigger than 53 - PASS
- 8.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - PASS
- 8.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - PASS
- 8.23 Stopping Mininet - PASS
- 8.24 Copying karaf logs - PASS
...
FAIL
Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology, stratum switches and 3 ONOS instances -
...
FAIL
Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology
- 15.1 Apply cell to environment - PASS
- 15.2 Uninstalling Atomix - PASS
- 15.3 Uninstalling ONOS package - PASS
- 15.4 Create Cluster Config - PASS
- 15.5 Installing Atomix via docker containers - PASS
- 15.6 Installing ONOS via docker containers - PASS
- 15.7 Set up ONOS secure SSH - PASS
- 15.8 Starting ONOS CLI sessions - PASS
- 15.9 Checking ONOS nodes - PASS
- 15.10 Checking ONOS applications - PASS
- 15.11 Set logging levels - PASS
- 15.12 Set ONOS configurations - PASS
- 15.13 Starting Mininet Topology - PASS
- 15.14 Configure switches in ONOS - PASS
- 15.15 Check whether the flow count is bigger than 28 - PASS
- 15.16 Check whether all flow status are ADDED - PASS
- 15.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 28 - PASS
- 15.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE15 - PASS
- 15.19 Stopping Mininet - PASS
- 15.20 Copying karaf logs - PASS
...
, stratum switches and 3 ONOS instances -
...
FAIL
Case 8
- 16.1 Apply cell to environment - PASS
- 16.2 Uninstalling Atomix - PASS
- 16.3 Uninstalling ONOS package - PASS
- 16.4 Create Cluster Config - PASS
- 16.5 Installing Atomix via docker containers - PASS
- 16.6 Installing ONOS via docker containers - PASS
- 16.7 Set up ONOS secure SSH - PASS
- 16.8 Starting ONOS CLI sessions - PASS
- 16.9 Checking ONOS nodes - PASS
- 16.10 Checking ONOS applications - PASS
- 16.11 Set logging levels - PASS
- 16.12 Set ONOS configurations - PASS
- 16.13 Starting Mininet Topology - PASS
- 16.14 Configure switches in ONOS - PASS
- 16.15 Check whether the flow count is bigger than 74 - PASS
- 16.16 Check whether all flow status are ADDED - PASS
- 16.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 37 - PASS
- 16.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 37 - PASS
- 16.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE16 - PASS
- 16.20 Stopping Mininet - PASS
- 16.21 Copying karaf logs - PASS
...
: Bridging test between two
...