Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
- 63.1 Apply cell to environment - PASS
- 63.2 Uninstalling Atomix - PASS
- 63.3 Uninstalling ONOS package - PASS
- 63.4 Create Cluster Config - PASS
- 63.5 Installing Atomix via docker containers - PASS
- 63.6 Installing ONOS via docker containers - PASS
- 63.7 Set up ONOS secure SSH - PASS
- 63.8 Starting ONOS CLI sessions - PASS
- 63.9 Checking ONOS nodes - PASS
- 63.10 Checking ONOS applications - PASS
- 63.11 Set logging levels - PASS
- 63.12 Set ONOS configurations - PASS
- 63.13 Starting Mininet Topology - PASS
- 63.14 Configure switches in ONOS - PASS
- 63.15 Check whether the flow count is bigger than 104 - PASS
- 63.16 Check whether all flow status are ADDED - PASS
- 63.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS
- 63.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS
- 63.19 Check whether the flow count of device device:bmv2:leaf1 is bigger than 52 - PASS
- 63.20 Check whether the flow count of device device:bmv2:leaf2 is bigger than 52 - PASS
- 63.21 Check whether the flow count is bigger than 104 - PASS
- 63.22 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 63.23 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS
- 63.24 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - FAIL IP connectivity failed
- PASS
- 63.25 Stopping Mininet - PASS
- 63.26 Copying karaf logs - PASS
...
- 203.1 Apply cell to environment - PASS
- 203.2 Uninstalling Atomix - PASS
- 203.3 Uninstalling ONOS package - PASS
- 203.4 Create Cluster Config - PASS
- 203.5 Installing Atomix via docker containers - PASS
- 203.6 Installing ONOS via docker containers - PASS
- 203.7 Set up ONOS secure SSH - PASS
- 203.8 Starting ONOS CLI sessions - PASS
- 203.9 Checking ONOS nodes - PASS
- 203.10 Checking ONOS applications - PASS
- 203.11 Set logging levels - PASS
- 203.12 Set ONOS configurations - PASS
- 203.13 Starting Mininet Topology - PASS
- 203.14 Configure switches in ONOS - PASS
- 203.15 Check whether the flow count is bigger than 106 - PASS
- 203.16 Check whether all flow status are ADDED - PASS
- 203.17 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_Before - PASS
- 203.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_Before - PASS
- 203.19 Check whether the flow count of device device:bmv2:leaf1 is bigger than 53 - PASS
- 203.20 Check whether the flow count of device device:bmv2:leaf2 is bigger than 53 - PASS
- 203.21 Check whether the flow count is bigger than 106 - PASS
- 203.22 Check whether all flow status are ADDED - PASS
- 203.23 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_After - PASS
- 203.24 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_After - PASS
- 203.25 Stopping Mininet - PASS
- 203.26 Copying karaf logs - PASS
Case 213: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 213.1 Apply cell to environment - PASS
- 213.2 Uninstalling Atomix - PASS
- 213.3 Uninstalling ONOS package - PASS
- 213.4 Create Cluster Config - PASS
- 213.5 Installing Atomix via docker containers - PASS
- 213.6 Installing ONOS via docker containers - PASS
- 213.7 Set up ONOS secure SSH - PASS
- 213.8 Starting ONOS CLI sessions - PASS
- 213.9 Checking ONOS nodes - PASS
- 213.10 Checking ONOS applications - PASS
- 213.11 Set logging levels - PASS
- 213.12 Set ONOS configurations - PASS
- 213.13 Starting Mininet Topology - PASS
- 213.14 Configure switches in ONOS - PASS
- 213.15 Check whether the flow count is bigger than 106 - PASS
- 213.16 Check whether all flow status are ADDED - PASS
- 213.17 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_Before - PASS
- 213.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_Before - PASS
- 213.19 Check whether the flow count of device device:bmv2:leaf1 is bigger than 53 - PASS
- 213.20 Check whether the flow count of device device:bmv2:leaf2 is bigger than 53 - PASS
- 213.21 Check whether the flow count is bigger than 106 - PASS
- 213.22 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 213.23 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_After - PASS
- 213.24 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_After - PASS
- 213.25 Stopping Mininet - PASS
- 213.26 Copying karaf logs - PASS
...