<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRBridging-stratum_onos-2.2_20-builds_graph.jpg", alt="SRBridging-stratum", style="width:525px;height:350px;border:0">

commit 84e2ecffb63420ac8b8221bbe9cb353c0176a5cd 35e4d196eb61104e7f96c62361a100bb454ee1cf (HEAD -] onos-2.2, origin/onos-2.2)
Author: Andrea Campanella Robert MacDavid [andrea@opennetworkingrobert@opennetworking.org]
AuthorDate: Mon Tue Oct 19 1020 13:4436:15 12 2020 +0200-0400
Commit: Andrea Campanella Robert MacDavid [andrea@opennetworkingrobert@opennetworking.org]
CommitDate: Mon Oct 19 11Tue Oct 20 18:21:44 :51 2020 +0200
Escaping regex reserved chars-0400

Update SPGW p4 namespace to match fabric-tna

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, stratum switches and 3 ONOS instances - PASS

...

  • 77.1 Apply cell to environment - PASS (tick)
  • 77.2 Uninstalling Atomix - PASS (tick)
  • 77.3 Uninstalling ONOS package - PASS (tick)
  • 77.4 Create Cluster Config - PASS (tick)
  • 77.5 Installing Atomix via docker containers - PASS (tick)
  • 77.6 Installing ONOS via docker containers - PASS (tick)
  • 77.7 Set up ONOS secure SSH - PASS (tick)
  • 77.8 Starting ONOS CLI sessions - PASS (tick)
  • 77.9 Checking ONOS nodes - PASS (tick)
  • 77.10 Checking ONOS applications - PASS (tick)
  • 77.11 Set logging levels - PASS (tick)
  • 77.12 Set ONOS configurations - PASS (tick)
  • 77.13 Starting Mininet Topology - PASS (tick)
  • 77.14 Configure switches in ONOS - PASS (tick)
  • 77.15 Check whether the flow count is bigger than 64 - PASS (tick)
  • 77.16 Check whether all flow status are ADDED - PASS (tick)
  • 77.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 32 - PASS (tick)
  • 77.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 32 - PASS (tick)
  • 77.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE77 - PASS (tick)
  • 77.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE77 - PASS (tick)
  • 77.21 Stopping Mininet - PASS (tick)
  • 77.22 Copying karaf logs - PASS (tick)

Case 78: Bridging test between untagged and tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology, stratum switches and 3 ONOS instances -

...

PASS

  • 78.1 Apply cell to environment - PASS (tick)
  • 78.2 Uninstalling Atomix - PASS (tick)
  • 78.3 Uninstalling ONOS package - PASS (tick)
  • 78.4 Create Cluster Config - PASS (tick)
  • 78.5 Installing Atomix via docker containers - PASS (tick)
  • 78.6 Installing ONOS via docker containers - PASS (tick)
  • 78.7 Set up ONOS secure SSH - PASS (tick)
  • 78.8 Starting ONOS CLI sessions - PASS (tick)
  • 78.9 Checking ONOS nodes - PASS (tick)
  • 78.10 Checking ONOS applications - PASS (tick)
  • 78.11 Set logging levels - PASS (tick)
  • 78.12 Set ONOS configurations - PASS (tick)
  • 78.13 Starting Mininet Topology - PASS (tick)
  • 78.14 Configure switches in ONOS - PASS (tick)
  • 78.15 Check whether the flow count is bigger than 212 - PASS (tick)
  • 78.16 Check whether all flow status are ADDED - PASS (tick)
  • 78.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 53 - PASS (tick)
  • 78.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 49
  • PASS (tick)
  • 78.19 Check whether the flow count of device device:bmv2:leaf3 is bigger than 53 - PASS (tick)
  • 78.20 Check whether the flow count of device device:bmv2:leaf4 is bigger than 53 - PASS (tick)
  • 78.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE78 - PASS (tick)
  • 78.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE78 - PASS (tick)
  • 78.23 Stopping Mininet - PASS (tick)